🇵🇱 CENTRUM TECHNIKI OKRĘTOWEJ S.A. PL
EnvironmentConstructionMaterials & polymers
CENTRUM TECHNIKI OKRĘTOWEJ S.A. is a laboratory accredited by PCA under number AB 1241 (Gdańsk, Poland). Its accreditation scope covers 42 test methods in the following areas: Environment, Construction, Materials & polymers. Test objects include: Machines and devices emitting noise to the environment E, Environment for mechanical exposures of technical devices weighing…, Premises in residential buildings, collective residence buildings a…, Acoustic booths: single objects used in offices to provide local pl…. Most frequently used techniques: Direct measurement method, Accurate method, „In situ” method.
At a glance
- Accreditation number: PCA AB 1241
- Methods in scope: 42
- Types of test objects: 23
- Techniques used: 9
- City: Gdańsk, Poland
- Accreditation number
- AB 1241
- Accreditation body
- PCA
- Address
- ZAKŁAD BADAWCZO-ROZWOJOWY, ZESPÓŁ LABORATORIÓW BADAŃ ŚRODOWISKOWYCH, LABORATORIUM BADAŃ WIBROAKUSTYCZNYCH, ul. Szczecińska 65, 80-392 Gdańsk, MARITIME ADVANCED RESEARCH CENTRE
- City
- Gdańsk, Poland
What this laboratory tests (23)
- Machines and devices emitting noise to the environment E — 6 methods
- Environment for mechanical exposures of technical devices weighing up to 3000 kg E — 4 methods
- Premises in residential buildings, collective residence buildings and public utility buildings – noise from technical building equipment penetrating into the premises — 4 methods
- Acoustic booths: single objects used in offices to provide local places with enhanced sound insulation. — 3 methods
- Acoustic screens — 2 methods
- Air terminal devices and units, dampers and valves E — 2 methods
- Occupational environment - noise — 2 methods
- Premises and spaces on vessels - noise E — 2 methods
- Rechargeable energy storage systems (REESS) E — 2 methods
- Rooms in residential, collective residence and public utility buildings – noise — 2 methods
- Airborne sound insulation — 1 method
- An environment for mechanical exposures, intended for technical devices weighing from 1000 kg up to 3000 kg E — 1 method
- An environment for mechanical exposures, intended for technical devices weighing up to 1000 kg E — 1 method
- An environment for mechanical exposures, intended for technical devices with dimensions of up to 0,8 m in width, 1,5 m in height and 2,0 m in length; Environmental engineering tests - construction products and materials E — 1 method
- An environment for mechanical exposures, intended for technical devices with dimensions of up to 6 m in width, 2,5 m in height and 5 m in length; Environmental engineering tests - construction products and materials E — 1 method
- and 8 more
Analytical techniques used (9)
- Direct measurement method — 6 methods
- Accurate method — 2 methods
- „In situ” method — 1 method
- Indicative method — 1 method
- Interrupted noise method — 1 method
- Method: Test Fc — 1 method
- Method: Test Ff — 1 method
- Method: Test Fh — 1 method
- Technical method — 1 method
Laboratory locations
- CENTRUM TECHNIKI OKRĘTOWEJ S.A. (main site) — ul. Szczecińska 65, 80-392 Gdańsk
- RESEARCH AND DEVELOPMENT DEPARTMENT — ul. Szczecińska 65
- ENVIRONMENTAL TESTING LABORATORY GROUP — ul. Szczecińska 65
- VIBROACOUSTIC TESTING LABORATORY — ul. Szczecińska 65
- Vibroacoustic Tests Laboratory — ul. Szczecińska 65, 80-392 Gdańsk
Certificate information
- Issue date
- 09.07.2026
- Issue no.
- 21
Accreditation scope — test methods (42)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Vibroacoustic Tests Laboratory | |||||
| 1 | Occupational environment - noise | A-weighted equivalent sound pressure level A-weighted maximum sound pressure level C-weighted peak sound pressure level Range (24 - 135) dB Range (24 - 135) dB Regulated area: + Tests performed in and outside the laboratory. |
Direct measurement method | PN-N-01307:1994 | PN EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – clauses 10 and 11 | PN EN ISO 9612:2025 excluding the method covering strategies 2 and 3 – clauses 10 and 11 | |
| 2 | Occupational environment - noise | A-weighted noise exposure level normalized to: - an 8-hour working day, - an average working week (calculated) an 8 h working day (daily noise exposure level) average weekly working hours Regulated area: + Tests performed in and outside the laboratory. |
PN-N-01307:1994 | PN EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – clauses 10 and 11 | PN EN ISO 9612:2025 excluding the method covering strategies 2 and 3 – clauses 10 and 11 | ||
| 3 | Acoustic screens | A-weighted equivalent sound pressure level Sound pressure level in 1/3 octave bands Range (24 - 135) dB The range (24 - 135) dB Range of centre frequencies of 1/3-octave bands (50 - 12 500) Hz Frequency range of 1/3-octave centre bands (50 - 12 500) Hz Regulated area: + Tests performed in and outside the laboratory. |
Direct measurement method | PN ISO 10847:2002 | |
| 4 | Acoustic screens | Efficiency of in situ screens (calculated) Regulated area: + Tests performed in and outside the laboratory. |
PN ISO 10847:2002 | ||
| 5 | Rooms in residential, collective residence and public utility buildings – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (24 – 130) dB |
Direct measurement method | PN-87/B-02156 | |
| 6 | Rooms in residential, collective residence and public utility buildings – noise | A-weighted equivalent sound level for reference time T (calculated) Regulated area: + Tests performed in and outside the laboratory. |
PN-87/B-02156 | ||
| 7 | Premises in residential buildings, collective residence buildings and public utility buildings – noise from technical building equipment penetrating into the premises | A- and C-weighted equivalent sound pressure level A- and C-weighted maximum sound pressure level Range (24 - 130) dB The range (24 - 130) dB Regulated area: + Tests performed in and outside the laboratory. |
Direct measurement method | PN-EN ISO 16032:2024 | |
| 8 | Premises in residential buildings, collective residence buildings and public utility buildings – noise from technical building equipment penetrating into the premises | A-weighted equivalent sound pressure level for the reference time T (calculated) Regulated area: + Tests performed in and outside the laboratory. |
PN-EN ISO 16032:2024 | ||
| 9 | Premises in residential buildings, collective residence buildings and public utility buildings – noise from technical building equipment penetrating into the premises | A-, C-weighted equivalent sound level A-, C-weighted maximum sound level Range (24 – 130) dB |
Direct measurement method | PN-EN ISO 10052:2021 | |
| 10 | Premises in residential buildings, collective residence buildings and public utility buildings – noise from technical building equipment penetrating into the premises | Reference equivalent A, C sound level for the operating cycle Reference maximum A, C sound level for the operating cycle (calculated) Regulated area: + Tests performed in and outside the laboratory. |
PN-EN ISO 10052:2021 | ||
| 11 | Acoustic booths: single objects used in offices to provide local places with enhanced sound insulation. | A-weighted sound insulation DpA in 1/3-octave bands Range of band centre frequencies (100 – 10 000) Hz Frequency range of 1/3-octave centre bands (100 - 10 000) Hz |
PN-EN ISO 11957:2010 | ||
| 12 | Acoustic booths: single objects used in offices to provide local places with enhanced sound insulation. | A-weighted sound insulation index Dp,W (calculated) | PN-EN ISO 717-1:2021-06 | ||
| 13 | Acoustic booths: single objects used in offices to provide local places with enhanced sound insulation. | Level reduction D in octave bands Speech level reduction DS.,A Range of band centre frequencies (125 – 8 000) Hz Frequency range of center bands (125 - 8 000) Hz |
ISO 23351-1:2020 | ||
| 14 | Construction products: - internal walls, external walls and their elements - external, internal doors - windows, panes, roof windows, shutters, blinds, - building and ventilation elements and other objects with an area of less than 1m2 - road traffic noise reducing devices - acoustic barriers E | Airborne sound insulation Range of centre frequencies of 1/3-octave bands (50 - 5 000) Hz Frequency range of 1/3-octave centre bands (50 - 5 000) Hz Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. "N" – Test method used in activities relevant to notification according to Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the "*" symbol. Conformity assessment for EU Regulation No 305/2011 (CPR), EC Decisions 99/93/EC, 98/437/EC. Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the manner of declaring the performance of building products and the method of marking them with the construction mark (Journal of Laws, item 1966) |
PN-EN ISO 10140-1 „N“ | PN-EN ISO 10140-2 „N“ | PN-EN ISO 10140-4 | PN-EN ISO 10140-5 | ASTM E90 | ||
| 15 | Construction products: - sound absorbing materials, objects and devices being interior equipment - road traffic noise reducing devices - acoustic barriers E | Sound absorption coefficient measured in a reverberation room Range of centre frequencies of 1/3-octave bands (50 ÷ 5 000) Hz Frequency range of 1/3-octave centre bands (50 - 5 000) Hz Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. "N" – Test method used in activities relevant to notification according to Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. Conformity assessment for EU Regulation No 305/2011 (CPR), EC Decisions 99/93/EC, 98/437/EC. Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the manner of declaring the performance of building products and the method of marking them with the construction mark (Journal of Laws, item 1966) |
Interrupted noise method | PN-EN ISO 354 „N“ | |
| 16 | Ship components: - ship panels - ship walls: bulkheads, lining panels - ship doors and windows E | Airborne sound insulation Range of centre frequencies of 1/3-octave bands (50 - 5 000) Hz Frequency range of 1/3-octave centre bands (50 - 5 000) Hz Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. "N" – Test method used in activities relevant to notification according to Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the "*" symbol. Conformity assessment for EU Regulation No 305/2011 (CPR), EC Decisions 99/93/EC, 98/437/EC. Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the manner of declaring the performance of building products and the method of marking them with the construction mark (Journal of Laws, item 1966) |
PN-EN ISO 10140-1 „N“ | PN-EN ISO 10140-2 „N“ | PN-EN ISO 10140-4 | PN-EN ISO 10140-5 | ASTM E90 | ||
| 17 | Internal walls and construction partitions E | Airborne sound insulation Range of centre frequencies of 1/3-octave bands (50 ÷ 5 000) Hz Frequency range of 1/3-octave centre bands (50 - 5 000) Hz Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. + Tests performed in and outside the laboratory. |
„In situ” method | PN-EN ISO 140-4 | PN-EN ISO 16283-1 | |
| 18 | Machines and devices emitting noise to the environment E | A-weighted time-averaged sound pressure level, A-weighted single event time-integrated sound pressure level Range of centre frequencies of 1/3-octave bands (100 ÷ 10 000) Hz Frequency range of 1/3-octave centre bands (100 - 10 000) Hz Sound pressure level range (24 ÷ 135) dB Sound pressure level range (24 - 135) dB Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Accurate method | PN EN ISO 3741 excluding cl. 9.2 | |
| 19 | Machines and devices emitting noise to the environment E | Sound power level (from calculations) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN EN ISO 3741 excluding cl. 9.2 | ||
| 20 | Machines and devices emitting noise to the environment E | A-weighted time-averaged sound pressure level, A-weighted single event time-integrated sound pressure level Range of centre frequencies of 1/3-octave bands (100 - 10 000) Hz Frequency range of 1/3-octave centre bands (100 - 10 000) Hz Sound pressure level range (24 - 135) dB Sound pressure level range (24 - 135) dB Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. + Tests performed in and outside the laboratory. |
Technical method | PN EN ISO 3744 excluding cl. 8.3 | |
| 21 | Machines and devices emitting noise to the environment E | Sound power level (from calculations) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. + Tests performed in and outside the laboratory. |
PN EN ISO 3744 excluding cl. 8.3 | ||
| 22 | Machines and devices emitting noise to the environment E | A-weighted time-averaged sound pressure level, A-weighted single event time-integrated sound pressure level Range of centre frequencies of 1/1 oct bands (125 - 8 000) Hz Frequency range of 1/1-octave centre bands (125 - 8 000) Hz Sound pressure level range (24 - 135) dB Sound pressure level range (24 - 135) dB Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. + Tests performed in and outside the laboratory. |
Indicative method | PN EN ISO 3746 excluding cl. 8.4 | |
| 23 | Machines and devices emitting noise to the environment E | Sound power level (from calculations) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. + Tests performed in and outside the laboratory. |
PN EN ISO 3746 excluding cl. 8.4 | ||
| 24 | Air terminal devices and units, dampers and valves E | A-weighted time-averaged sound pressure level, A-weighted single event time-integrated sound pressure level Range of centre frequencies of 1/3-octave bands (100 - 10 000) Hz Frequency range of 1/3-octave centre bands (100 - 10 000) Hz Sound pressure level range (24 - 135) dB Sound pressure level range (24 - 135) dB Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Accurate method | PN EN ISO 3741 excluding cl. 9.2 | PN-EN ISO 5135 excluding cl. 5.3 | |
| 25 | Air terminal devices and units, dampers and valves E | Sound power level (from calculations) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN EN ISO 3741 excluding cl. 9.2 | PN-EN ISO 5135 excluding cl. 5.3 | ||
| 26 | Premises and spaces on vessels - noise E | A-weighted equivalent sound pressure level C-weighted equivalent sound pressure level C-weighted peak sound pressure level Sound pressure level in 1/1 octave bands Range (24,0 - 135,0) dB Range (24 - 135) dB Range of centre frequencies of 1/1 oct bands (31,5 - 8 000) Hz The range of 1/1 octave band centre frequencies (31,5 - 8 000) Hz Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the "*" symbol. |
Direct measurement method | IMO RESOLUTION MSC.337(91) | PN EN ISO 9612 excluding the method covering strategies 2 and 3 – clauses 10 and 11 | |
| 27 | Premises and spaces on vessels - noise E | Noise exposure level referenced to a 24-hour time period Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the "*" symbol. |
IMO RESOLUTION MSC.337(91) | PN EN ISO 9612 excluding the method covering strategies 2 and 3 – clauses 10 and 11 | ||
| 28 | An environment for mechanical exposures, intended for technical devices with dimensions of up to 0,8 m in width, 1,5 m in height and 2,0 m in length; Environmental engineering tests - construction products and materials E | Broadband acoustic vibrations in the range (50 Hz – 10 kHz) at the sound pressure level Leq (100 – 135) dB. Broadband acoustic vibrations in the range (50 Hz – 10 kHz) sound pressure level Leq (100 – 135) dB Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. + Tests performed in and outside the laboratory. |
NO-06-A107 cl. 2.6, cl. 3.3 | ||
| 29 | An environment for mechanical exposures, intended for technical devices with dimensions of up to 6 m in width, 2,5 m in height and 5 m in length; Environmental engineering tests - construction products and materials E | Broadband acoustic vibrations in the range (50 Hz – 10 kHz) at the sound pressure level Leq (100 – 130) dB. Broadband acoustic vibrations in the range (50 Hz – 10 kHz) sound pressure level Leq (100 – 130) dB Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
NO-06-A107 cl. 2.6, cl. 3.3 | ||
| 30 | An environment for mechanical exposures, intended for technical devices weighing up to 1000 kg E | Non-repetitive and repetitive mechanical shocks Amplitude range (0 – 2 200) m/s2 The peak acceleration range (0 - 2 200) m/s2 Duration (3,5 – 50) ms Duration time (3,5 - 50) ms Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
NO-06-A107 point 2.5, point 2.9, point 2.10, point 2.13 | PN-EN 60068-2-27 | NO-20-A500-5 | ||
| 31 | An environment for mechanical exposures, intended for technical devices weighing from 1000 kg up to 3000 kg E | Non-repetitive and repetitive mechanical shocks Duration (10 - 50) ms Duration time (10 - 50) ms Amplitude range (0 – 50) m/s2 The amplitude peak acceleration range (0 - 50) m/s2 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
NO-06-A107 point 2.5, point 2.9, point 2.10, point 2.13 | PN-EN 60068-2-27 | NO-20-A500-5 | ||
| 32 | Environment for mechanical exposures of technical devices weighing up to 3000 kg E | Sinusoidal vibration, broadband vibration Frequency range (1 – 150) Hz The frequency range (1 - 150) Hz Amplitude range (0 – 3) g The amplitude range (0 - 3) g Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
NO-06-A107 point 2.2, point 2.3, point 2.4, point 2.7, point 2.8, point 2.10, point 2.12 | ||
| 33 | Environment for mechanical exposures of technical devices weighing up to 3000 kg E | Sinusoidal vibration Frequency range (1 – 150) Hz The frequency range (1 - 150) Hz Amplitude range (0 – 3) g The amplitude range (0 - 3) g Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: Test Fc | PN-EN 60068-2-6 | |
| 34 | Environment for mechanical exposures of technical devices weighing up to 3000 kg E | Time-history and sine-beat method Frequency range (1 – 150) Hz The frequency range (1 - 150) Hz Amplitude range (0 – 3) g The amplitude range (0 - 3) g Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: Test Ff | PN-EN 60068-2-57 | |
| 35 | Environment for mechanical exposures of technical devices weighing up to 3000 kg E | Broadband vibration Frequency range (1 – 150) Hz The frequency range (1 – 150) Hz Amplitude range (0 – 3) g The amplitude range (0 – 3) g Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: Test Fh | PN-EN 60068-2-64 excluding Annex „C” | |
| 36 | Rechargeable energy storage systems (REESS) E | Simulation of a mechanical vibration load – sinusoidal vibration Frequency range (1 – 200) Hz The frequency range (1 – 200) Hz Amplitude range (1-20) m/s2 The amplitude range (1-20) m/s2 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
UN Regulation No. 100 Annex 9A (UN Regulation No. 100 Annex 9A) | UN Regulation No. 136 Annex 8A (UN Regulation No. 136 Annex 8A) | PN-EN ISO 18243 point 8.1 | ||
| 37 | Rechargeable energy storage systems (REESS) E | Resistance to mechanical vibrations (shocks), objects weighing up to 1000 kg Objects with their weight up to 1000 kg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
UN Regulation No. 100 Annex 9C (UN Regulation No. 100, Annex 9C) | UN Regulation No. 136 Annex 8D (UN Regulation No. 136, Annex 8D) | ISO 6469-1 point 6.2.3 | PN-EN ISO 18243 point 8.2 | ||
| 38 | Vibrations on vessels E | Mechanical tests – measurement of the mechanical vibration level, Acceleration – aw, Velocity - vw Amplitude range (0,1 - 100) m/s2 The range (0,1 - 100) m/s2 Range (0,002 - 2,8) m/s The range (0,002 - 2,8) m/s Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. + Tests performed in and outside the laboratory. |
ISO 2631-1 | ISO 2631-2 | ISO 20283-5 | ||
| 39 | Doors, windows, shutters, blinds and related building hardware | ASSESSMENT OF PERFORMANCE BASED ON TESTS AND CALCULATIONS (System 3) / ASSESMENT OF PERFORMANCE BASED ON TESTS AND CALCULATIONS (System 3) Number of the decision of the Commission 99/93/EC Product(s) tested Doors, windows, shutters, blinds and related building hardware Harmonised technical specifications EN 14351-1:2006+A2:2016 Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE BASED ON TESTS AND CALCULATIONS (System 3). Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011, as amended, laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended). The current "List of subcontractors" is available on request from the accredited body. The laboratory meets the requirements of Regulation No 305/2011 of 9 March 2011 for the activities provided for a testing laboratory (Annex V, Section 2, point 3 of Regulation No 305/2011) in the above scope. Conformity assessment for EU Regulation No 305/2011 (CPR), EC Decisions 99/93/EC, 98/437/EC. Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the manner of declaring the performance of building products and the method of marking them with the construction mark (Journal of Laws, item 1966) |
EN 14351-1:2006+A2:2016 | ||
| 40 | Finishing of interior, exterior walls and ceilings | ASSESSMENT OF PERFORMANCE BASED ON TESTS AND CALCULATIONS (System 3) / ASSESMENT OF PERFORMANCE BASED ON TESTS AND CALCULATIONS (System 3) Number of the decision of the Commission 98/437/EC Product(s) tested Finishing of interior, exterior walls and ceilings Harmonised technical specifications EN 14509:2013 Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE BASED ON TESTS AND CALCULATIONS (System 3). Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011, as amended, laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended). The current "List of subcontractors" is available on request from the accredited body. The laboratory meets the requirements of Regulation No 305/2011 of 9 March 2011 for the activities provided for a testing laboratory (Annex V, Section 2, point 3 of Regulation No 305/2011) in the above scope. Conformity assessment for EU Regulation No 305/2011 (CPR), EC Decisions 99/93/EC, 98/437/EC. Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the manner of declaring the performance of building products and the method of marking them with the construction mark (Journal of Laws, item 1966) |
EN 14509:2013 | ||
| 41 | Sound absorption | ASSESSMENT OF PERFORMANCE / ASSESMENT OF PERFORMANCE Essential characteristic Sound absorption Technical specification EN ISO 354 Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE. Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011, as amended, laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended). The laboratory meets the requirements of Regulation No 305/2011 of 9 March 2011 for the activities provided for a testing laboratory (Annex V, Section 2, point 3 of Regulation No 305/2011) in the above scope. Conformity assessment for EU Regulation No 305/2011 (CPR), EC Decisions 99/93/EC, 98/437/EC. Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the manner of declaring the performance of building products and the method of marking them with the construction mark (Journal of Laws, item 1966) |
EN ISO 354 | ||
| 42 | Airborne sound insulation | ASSESSMENT OF PERFORMANCE / ASSESMENT OF PERFORMANCE Essential characteristic Airborne sound insulation Technical specification EN ISO 10140-1 EN ISO 10140-2 EN ISO 10140-4 EN ISO 10140-5 Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE. Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011, as amended, laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended). The laboratory meets the requirements of Regulation No 305/2011 of 9 March 2011 for the activities provided for a testing laboratory (Annex V, Section 2, point 3 of Regulation No 305/2011) in the above scope. Conformity assessment for EU Regulation No 305/2011 (CPR), EC Decisions 99/93/EC, 98/437/EC. Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the manner of declaring the performance of building products and the method of marking them with the construction mark (Journal of Laws, item 1966) |
EN ISO 10140-1 | EN ISO 10140-2 | EN ISO 10140-4 | EN ISO 10140-5 | ||
Reference standards (49)
ASTM E90
EN 14351-1:2006+A2:2016
EN 14509:2013
EN ISO 10140-1
EN ISO 10140-2
EN ISO 10140-4
EN ISO 10140-5
EN ISO 354
IMO RESOLUTION MSC.337(91)
ISO 20283-5
ISO 23351-1:2020
ISO 2631-1
ISO 2631-2
ISO 6469-1 point 6.2.3
NO-06-A107 point 2.2, point 2.3, point 2.4, point 2.7, point 2.8, point 2.10, point 2.12
NO-06-A107 point 2.5, point 2.9, point 2.10, point 2.13
NO-06-A107 cl. 2.6, cl. 3.3
NO-20-A500-5
PN EN ISO 3741 excluding cl. 9.2
PN EN ISO 3744 excluding cl. 8.3
PN EN ISO 3746 excluding cl. 8.4
PN EN ISO 9612 excluding the method covering strategies 2 and 3 – clauses 10 and 11
PN EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – clauses 10 and 11
PN EN ISO 9612:2025 excluding the method covering strategies 2 and 3 – clauses 10 and 11
PN ISO 10847:2002
PN-87/B-02156
PN-EN 60068-2-27
PN-EN 60068-2-57
PN-EN 60068-2-6
PN-EN 60068-2-64 excluding Annex „C”
PN-EN ISO 10052:2021
PN-EN ISO 10140-1 „N“
PN-EN ISO 10140-2 „N“
PN-EN ISO 10140-4
PN-EN ISO 10140-5
PN-EN ISO 11957:2010
PN-EN ISO 140-4
PN-EN ISO 16032:2024
PN-EN ISO 16283-1
PN-EN ISO 18243 point 8.1
PN-EN ISO 18243 point 8.2
PN-EN ISO 354 „N“
PN-EN ISO 5135 excluding cl. 5.3
PN-EN ISO 717-1:2021-06
PN-N-01307:1994
UN Regulation No. 100 Annex 9A (UN Regulation No. 100 Annex 9A)
UN Regulation No. 100 Annex 9C (UN Regulation No. 100, Annex 9C)
UN Regulation No. 136 Annex 8A (UN Regulation No. 136 Annex 8A)
UN Regulation No. 136 Annex 8D (UN Regulation No. 136, Annex 8D)