🇵🇱 Laboratorium Badawcze EHS-LAB Sp. z o.o. PL
EnvironmentWater & wastewater
Laboratorium Badawcze EHS-LAB Sp. z o.o. is a laboratory accredited by PCA under number AB 1226 (Kraków, Poland). Its accreditation scope covers 101 test methods in the following areas: Environment, Water & wastewater. Test objects include: Workplace environment - air *, Water and wastewater, Water, Wastewater. Most frequently used techniques: Gas chromatography with flame ionization detection (GC – FID), Direct measurement method, Spectrophotometric method.
At a glance
- Accreditation number: PCA AB 1226
- Methods in scope: 101
- Types of test objects: 14
- Techniques used: 21
- City: Kraków, Poland
- Accreditation number
- AB 1226
- Accreditation body
- PCA
- Address
- ul. Okólna 11/69, 30-669 Kraków
- City
- Kraków, Poland
What this laboratory tests (14)
- Workplace environment - air * — 52 methods
- Water and wastewater — 15 methods
- Water — 7 methods
- Wastewater — 5 methods
- Working environment - noise * — 4 methods
- General environment - noise from installations, equipment and industrial plants — 2 methods
- Working environment - cold microclimate * — 2 methods
- Working environment - hand-transmitted vibration * — 2 methods
- Working environment - hot microclimate * — 2 methods
- Working environment - lighting of the workplace with electric light * — 2 methods
- Working environment - whole-body vibration * — 2 methods
- Working environment – ultrasonic noise * — 2 methods
- Workplace environment - indoor electric lighting * — 2 methods
- Workplace environment - moderate microclimate * — 2 methods
Analytical techniques used (21)
- Gas chromatography with flame ionization detection (GC – FID) — 22 methods
- Direct measurement method — 10 methods
- Spectrophotometric method — 10 methods
- Gas chromatography with flame ionisation detection (GC-FID) — 5 methods
- Titrimetric method — 5 methods
- Gravimetric method — 4 methods
- High-performance liquid chromatography with spectrophotometric detection (HPLC UV) — 4 methods
- High-performance liquid chromatography with spectrophotometric detection (HPLC UV/DAD) — 3 methods
- Conductometric method — 2 methods
- Electrochemical method — 2 methods
- Gas chromatography with flame ionization detection (GC-FID) — 2 methods
- High-performance liquid chromatography (HPLC - UV) — 2 methods
- Manual method — 2 methods
- Personal dosimetry method — 2 methods
- Potentiometric method — 2 methods
- and 6 more
Laboratory locations
- Laboratorium Badawcze EHS-LAB Sp. z o.o. (main site) — ul. Okólna 11/69, 30-669 Kraków
- EHS-LAB Sp. z o.o. Testing Laboratory — ul. Okólna 11/69
- EHS-LAB Testing Laboratory — ul. Mogilska 80, 31-546 Kraków
Certificate information
- Issue date
- 10.06.2026
- Issue no.
- 25
Accreditation scope — test methods (101)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| EHS-LAB Testing Laboratory | |||||
| 1 | Working environment - noise * | A-weighted equivalent sound level Maximum A-weighted sound level Range (25 - 135) dB C-weighted peak sound pressure level Range (40 - 138) dB |
Direct measurement method | PN-EN ISO 9612:2011 excluding the methods covering strategies 2 and 3 – cl. 10 and 11 | PN-N-01307:1994 | |
| 2 | Working environment - noise * | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-EN ISO 9612:2011 excluding the methods covering strategies 2 and 3 – cl. 10 and 11 | PN-N-01307:1994 | ||
| 3 | Working environment – ultrasonic noise * | Equivalent sound pressure levels in bands one-third octave with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in bands one-third octave with centre frequencies from 10 kHz to 40 kHz Range (59 – 160) dB |
Direct measurement method | PN-Z-01339:2020-12 | |
| 4 | Working environment – ultrasonic noise * | Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-Z-01339:2020-12 | ||
| 5 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (25 – 135) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F | |
| 6 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F | ||
| 7 | Working environment - whole-body vibration * | Frequency-weighted r.m.s. vibration acceleration Range (0,01 – 40) m/s2 |
Direct measurement method; Sampling method | PN-EN 14253+A1:2011 | |
| 8 | Working environment - whole-body vibration * | Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz)., Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 9 | Working environment - hand-transmitted vibration * | Frequency-weighted r.m.s. vibration acceleration Range (0,06 – 60) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 10 | Working environment - hand-transmitted vibration * | Daily exposure, expressed as the 8-hour energy-equivalent vector sum of the effective frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz); Exposure lasting 30 minutes or less, expressed as the vector sum of the effective frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 11 | Working environment - cold microclimate * | Air temperature Range (-10 – 10) °C Black globe temperature Range (-10 – 10) °C Air humidity Range (25 – 75) % Air velocity Range (0,15 – 5) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 12 | Working environment - cold microclimate * | IREQmin index, IREQneutral index, twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 13 | Workplace environment - moderate microclimate * | Air temperature Range (10 – 40) °C Black globe temperature Range (10 – 40) °C Air humidity Range (25 – 75) % Air velocity Range (0,15 – 5) m/s |
Direct measurement method | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04 | |
| 14 | Workplace environment - moderate microclimate * | PMV index, PPD index (calculated) | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04 | ||
| 15 | Working environment - hot microclimate * | Air temperature Range (15 – 40) °C Natural wet bulb temperature Range (15 – 40) °C Black globe temperature Range (15 – 50) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 16 | Working environment - hot microclimate * | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | ||
| 17 | Workplace environment - indoor electric lighting * | Illuminance Range (5 – 5000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 18 | Workplace environment - indoor electric lighting * | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 19 | Workplace environment - air * | Gas concentrations: CO (2,3 – 200) mg/m3 |
Electrochemical method | EHS-PB-43 issue 3 of 01.06.2022 | |
| 20 | Workplace environment - air * | Exposure index (calculated) | EHS-PB-43 issue 3 of 01.06.2022 | ||
| 21 | Workplace environment - air * | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 22 | Workplace environment - air * | Sampling for the assessment of occupational exposure to: organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction metals and their compounds, including inhalable fraction respirable fraction |
Personal dosimetry method; Stationary method | PN-Z-04008-7:2002+Az1:2004 | |
| 23 | Workplace environment - air * | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 24 | Workplace environment - air * | Concentration of harmful dust agents – inhalable fraction apatites and phosphorites portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range (0,5 – 68,0) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 25 | Workplace environment - air * | Concentration of harmful dust agents – respirable fraction apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts talc coal (hard, brown) Range (0,3 – 14,6) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 26 | Workplace environment - air * | Concentration/content of acetonitrile, N,N-dimethylformamide acetonitrile: (2,2 – 250) mg/m3 Range (0,04 – 0,88) mg in the sample N,N-dimethylformamide: (0,5 – 60) mg/m3 (0,09 – 1,8) mg in the sample |
Gas chromatography with flame ionisation detection (GC-FID) | EHS-PB-1 issue 5 of 17.04.2019 | |
| 27 | Workplace environment - air * | Concentration/content of n-hexane, n-heptane n-hexane (5,0 – 200) mg/m3 Range (0,03 – 1,2) mg in the sample n-heptane (66,7 – 2667) mg/m3 (0,40 – 16,0) mg in the sample |
Gas chromatography with flame ionisation detection (GC-FID) | NIOSH Method 1500 Issue 3 (2003) | |
| 28 | Workplace environment - air * | Concentration/content of ethanol, propan-2-ol ethanol (180 – 4050) mg/m3 Range (0,18 – 4,05) mg in the sample propan-2-ol (80 – 1800) mg/m3 (0,24 – 5,40) mg in the sample |
Gas chromatography with flame ionisation detection (GC-FID) | NIOSH Method 1400 Issue 2 (1994) | |
| 29 | Workplace environment - air * | Concentration/content of tetrahydrofuran Range (15 – 300) mg/m3 Range (0,075 – 1,5) mg in the sample |
Gas chromatography with flame ionisation detection (GC-FID) | PN-Z-04481:2017-10 | |
| 30 | Workplace environment - air * | Methanol concentration/content Range (10 – 200) mg/m3 Range (0,05 – 1,00) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04476:2016-10 | |
| 31 | Workplace environment - air * | Acetic acid concentration/content Range (1,0 – 50) mg/m3 Range (0,025 – 1,25) mg in the sample |
Gas chromatography with flame ionisation detection (GC-FID) | PN-Z-04323:2004 | |
| 32 | Workplace environment - air * | Methyl acetate concentration/content methyl acetate (20 – 500) mg/m3 Range (0,20 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1458 Issue 2 (1994) EHS-PB-10 issue 5 of 29.05.2019 | |
| 33 | Workplace environment - air * | Ethyl acetate concentration/content Range (60 – 1500) mg/m3 Range (0,60 – 15) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | NIOSH Method 1457 Issue 1 (1994) EHS-PB-10 issue 5 of 29.05.2019 | |
| 34 | Workplace environment - air * | Concentration/content of n-propyl acetate, n-butyl acetate, n-amyl acetate n-propyl acetate (20 - 500) mg/m3 Range (0,20 – 5,0) mg in the sample n-butyl acetate (20 - 500) mg/m3 (0,20 – 5,0) mg in the sample pentyl acetate (20 – 500) mg/m3 (0,20 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1450 Issue 3 (2003) EHS-PB-10 issue 5 of 29.05.2019 | |
| 35 | Workplace environment - air * | Extraction naphtha concentration/content Range (12,5 – 1500) mg/m3 Range (0,125 – 6,0) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04134-02:1981 | |
| 36 | Workplace environment - air * | Concentration/content of benzene, toluene, ethylbenzene, o-xylene, m-xylene, p-xylene benzene (0,10 – 4,0) mg/m3 Range (0,003 – 0,12) mg in the sample toluene (5,0 – 200) mg/m3 (0,04 – 1,6) mg in the sample ethylbenzene (10 – 400) mg/m3 (0,24 – 9,6) mg in the sample o-xylene (7,5 – 300) mg/m3 (0,18 – 7,2) mg in the sample m-xylene (7,5 – 300) mg/m3 (0,18 – 7,2) mg in the sample p-xylene (7,5 – 300) mg/m3 (0,18 – 7,2) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1501 Issue 3 (2003) | |
| 37 | Workplace environment - air * | Concentration/content of acetone, 4-methylpentan-2-one acetone (60 – 2400) mg/m3 Range (0,18 – 7,2) mg in the sample 4-methylpentan-2-one (6,0 – 240) mg/m3 (0,06 – 2,4) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1300 Issue 2 (1994) | |
| 38 | Workplace environment - air * | Dichloromethane concentration/content dichloromethane (8,8 – 176) mg/m3 Range (0,0528 – 1,056) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04437:2011 | |
| 39 | Workplace environment - air * | Concentration/content of chloroform Range (0,40 – 16) mg/m3 Range (0,02 – 0,80) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1003 Issue 3 (2003) | |
| 40 | Workplace environment - air * | Concentration/content of 1-butanol Range (5,0 – 300) mg/m3 Range (0,05 – 3,0) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1405 Issue 1 (2003) | |
| 41 | Workplace environment - air * | White spirit concentration/content Range (2,78 – 614,7) mg/m3 Range (0,10 – 22,13) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | PN-81/Z-04134.03 | |
| 42 | Workplace environment - air * | Turpentine concentration/content Range (10 – 300) mg/m3 Range (0,10 – 3,0) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1551 Issue 2 (1994) | |
| 43 | Workplace environment - air * | Concentration/content of 1,4-dioxane Range (1,4 – 115) mg/m3 Range (0,05 – 4,13) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | Principles and Methods of Assessing the Working Environment 2009, No. 1 (59), pp. 141–146 | |
| 44 | Workplace environment - air * | Kerosene concentration/content Range (10,00 – 4800) mg/m3 Range (0,36 – 7,2) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04227-02:1992 | |
| 45 | Workplace environment - air * | Concentration/content of trimethylbenzenes, styrene, cyclohexane, cyclohexanone, butan-2-one 1,2,3-trimethylbenzene Range (9 – 4330) mg/m3 Range (0,32 – 6,5) mg in the sample 1,2,4-trimethylbenzene (10 – 4767) mg/m3 (0,36 – 7,2) mg in the sample 1,3,5-trimethylbenzene (10 – 4767) mg/m3 (0,36 – 7,2) mg in the sample Sum of trimethylbenzenes (calculated) styrene (5,3 – 2480) mg/m3 (0,19 – 3,7) mg in the sample cyclohexane (30 – 14400) mg/m3 (1,1 – 21,6) mg in the sample cyclohexanone (3,9 – 1920) mg/m3 (0,14 – 2,88) mg in the sample butan-2-one (45 – 22000) mg/m3 (1,6 – 32,5) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | Principles and Methods of Assessing the Working Environment 2007, No. 1 (51), pp. 141–147 | |
| 46 | Workplace environment - air * | Concentration/content of bis(2-ethylhexyl) adipate Range (40 – 800) mg/m3 Range (6 – 120) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04461:2015-10 | |
| 47 | Workplace environment - air * | Concentration/content of N,N-dimethylacetamide Range (2,0 – 160) mg/m3 Range (0,020 – 1,6) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04491:2017-10 | |
| 48 | Workplace environment - air * | Ethylene glycol concentration/content Range (1,50 – 100) mg/m3 Range (0,030 – 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | Principles and Methods of Assessing the Working Environment 1997, No. 17, pp. 55-59 | |
| 49 | Workplace environment - air * | 2-methoxy-1-methylethyl acetate concentration/content Range (26 – 1200) mg/m3 Range (0,26 – 12) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04119-10:2008 | |
| 50 | Workplace environment - air * | Concentration/content of 2-methoxypropyl acetate Range (10 – 400) mg/m3 Range (0,050 – 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04305:2003 | |
| 51 | Workplace environment - air * | Concentration/content of glycerol – inhalable fraction Range (1,01 – 20,20) mg/m3 Range (0,20 – 4,00) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04374:2009 | |
| 52 | Workplace environment - air * | Phenol concentration/content Range (0,71 – 30,30) mg/m3 Range (0,014 – 0,600) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 2546 Issue 1:1994 | |
| 53 | Workplace environment - air * | Concentration/content of 1,2-dichloroethane Range (0,82 – 16,40) mg/m3 Range (0,010 – 0,197) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04501:2019-10 | |
| 54 | Workplace environment - air * | Concentration/content of 1,2-dichloroethene – isomers: cis -, trans - cis 1,2-dichloroethene Range (70,70 – 1414,14) mg/m3 Range (0,70 – 14,00) mg in the sample trans 1,2-dichloroethene (70,70 – 1414,14) mg/m3 (0,70 – 14,00) mg in the sample |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04270:2000 | |
| 55 | Workplace environment - air * | Acrylic acid concentration/content Range (1,0 – 40) mg/m3 Range (0,02 – 0,8) mg in the sample |
High-performance liquid chromatography (HPLC - UV) | PN-Z-04460:2014-09 | |
| 56 | Workplace environment - air * | Concentration/content of hydroquinone Range (0,1 – 2) mg/m3 Range (0,0018 – 0,036) mg in the sample |
High-performance liquid chromatography (HPLC - UV) | PN-Z-04479:2016 | |
| 57 | Workplace environment - air * | Concentration/content of dibenzoyl peroxide Range (0,505 – 20,0) mg/m3 Range (0,050 – 2,0) mg in the sample |
High-performance liquid chromatography with spectrophotometric detection (HPLC UV/DAD) | Principles and Methods of Assessing the Working Environment 2016, No. 17, pp. 97-100 | |
| 58 | Workplace environment - air * | Concentration/content of phenolphthalein Range (0,33 – 16,7) mg/m3 Range (0,08 – 4,0) mg in the sample |
High-performance liquid chromatography with spectrophotometric detection (HPLC UV/DAD) | PN-Z-04506:2019-10 | |
| 59 | Workplace environment - air * | Concentration/content of ethyl 2-cyanoacrylate Range (0,10 – 4,0) mg/m3 Range (0,0012 – 0,048) mg in the sample |
High-performance liquid chromatography with spectrophotometric detection (HPLC UV/DAD) | PN-Z-04467:2016-10 | |
| 60 | Workplace environment - air * | Concentration/content of N-hydroxyurea Range (0,001 – 0,08) mg/m3 Range (0,48 – 38,4) μg in the sample |
High-performance liquid chromatography with spectrophotometric detection (HPLC UV) | Principles and Methods of Assessing the Working Environment 2010, No. 1 (63), pp. 155–162 | |
| 61 | Workplace environment - air * | Concentration/content of fluorouracil – inhalable fraction Range (0,00015 – 0,00733) mg/m3 Range (0,000105 – 0,00528) mg in the sample |
High-performance liquid chromatography with spectrophotometric detection (HPLC UV) | Principles and Methods of Assessing the Working Environment 2020, No. 2 (104), pp. 63–77 | |
| 62 | Workplace environment - air * | Concentration/content of acrylamide Range (0,0070 – 0,14) mg/m3 Range (0,00084 – 0,017) mg in the sample |
High-performance liquid chromatography with spectrophotometric detection (HPLC UV) | PN-Z-04486:2017-10 | |
| 63 | Workplace environment - air * | Concentration / content of hydrazine Range (0,00125 – 0,0769) mg/m3 Range (0,00094 – 0,0568) ppm Range (0,00030 – 0,0070) mg in the sample Range (0,00023 – 0,053) ppm |
High-performance liquid chromatography with spectrophotometric detection (HPLC UV) | PN-Z-04523:2020-12 | |
| 64 | Workplace environment - air * | Formaldehyde concentration/content Range (0,0133 – 60) mg/m3 Range (0,00040 – 0,0600) mg in the sample UV |
High-performance liquid chromatography with detection | Principles and Methods of Assessing the Working Environment 1999, No. 22, pp. 96 - 100 | |
| 65 | Workplace environment - air * | Chlorine concentration/content Range (0,12 – 8) mg/m3 Range (0,0005 – 0,008) mg in the sample |
Spectrophotometric method | PN-75/Z-04037/03 | |
| 66 | Workplace environment - air * | Hydrogen chloride concentration/content Range (0,5 – 10) mg/m3 Range (0,20 – 4,0) mg in the sample |
Turbidimetric method | PN-Z-04450:2014-08 | |
| 67 | Workplace environment - air * | Ammonia concentration/content Range (1,25– 60) mg/m3 Range (0,015 – 0,30) mg in the sample |
Spectrophotometric method | PN-Z-04041:1971 | |
| 68 | Workplace environment - air * | Concentration/content of highly refined mineral oils excluding metalworking fluids Range (0,42 – 41,7) mg/m3 Range (0,30 – 10,0) mg in the sample |
Spectrophotometric method | PN-Z-04108-6:2006 | PN-Z-04108-6:2006/Az1:2009 | |
| 69 | Wastewater | Sampling for chemical and physical testing Temperature of the collected wastewater sample Range (0,5 – 50) oC |
Manual method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 70 | Wastewater | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007 + Ap1:2007 | |
| 71 | Wastewater | Concentration of substances extractable with petroleum ether Range (2,0 – 100) mg/l |
Gravimetric method | EHS-PB-3 issue 2 of 20.08.15 | |
| 72 | Wastewater | Settleable solids Range (0,5 – 100) ml/l |
Volumetric method | PN-C-04559-03:1972 | |
| 73 | Water | Sampling for chemical and physical testing Temperature of the water sample taken Range (0,5 – 50) oC |
PN-ISO 5667-6:2016-12 | PN-77/C-04584 | ||
| 74 | Water | Total alkalinity Range (0,4 – 40) mmol/l Range (20 – 2000) mg/l CaCO3 |
Titrimetric method | PN-EN ISO 9963-1:2001+Ap1:2004 | |
| 75 | Water and wastewater | pH Range (2,0 – 12,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 76 | Water and wastewater | Electrical conductivity Range (10 – 12880) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 77 | Water and wastewater | Chloride concentration Range (5,0 – 1000) mg/I |
Titrimetric method | PN-ISO 9297:1994 | |
| 78 | Water and wastewater | Total iron concentration Range (0,01 – 20) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 79 | Water and wastewater | Nitrite concentration Range (0,01 – 40) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 80 | Water and wastewater | Phenol index Range (0,01 – 50) mg/l |
Spectrophotometric method | PN-ISO 6439:1994, cl. 4 | |
| 81 | Water and wastewater | Chemical oxygen demand – COD Range (10,0 – 1000) mg/I O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 82 | Water and wastewater | Phosphate concentration Range (0,01 – 50) mg/l Range (0,03 – 153) mg/l P-PO4 |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 | |
| 83 | Water and wastewater | Total phosphorus concentration Range (0,04 – 30) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 | |
| 84 | Water and wastewater | Concentration of ammonium nitrogen, ammonium ion ammonium nitrogen Range (0,050 – 325) mg/l ammonium ion Range (0,064 – 418) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 85 | Water and wastewater | Sulfate concentration Range (5 – 600) mg/l |
Turbidimetric method | EHS-PB-50 issue 1 of 05.06.2017 | based on the HACH method No. 8051 | |
| 86 | Water and wastewater | Biochemical oxygen demand - BOD5 Range (1 – 6000) mg/I O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 87 | Water and wastewater | Mineral oil index Range (0,10 – 50) mg/I GC-FID |
Gas chromatography with flame ionisation detection | PN-EN ISO 9377-2:2003 | |
| 88 | Working environment - noise * | A-weighted equivalent sound level Maximum A-weighted sound level Range (24 - 135) dB C-weighted peak sound pressure level Range (40 - 138) dB |
Direct measurement method | PN-EN ISO 9612:2011 excluding the methods covering strategies 2 and 3 – cl. 10 and 11 | PN-N-01307:1994 | |
| 89 | Working environment - noise * | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-EN ISO 9612:2011 excluding the methods covering strategies 2 and 3 – cl. 10 and 11 | PN-N-01307:1994 | ||
| 90 | Working environment - lighting of the workplace with electric light * | Illuminance Range (5 – 5000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 91 | Working environment - lighting of the workplace with electric light * | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 92 | Workplace environment - air * | Sampling for the assessment of occupational exposure to: industrial dusts inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 93 | Workplace environment - air * | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 94 | Wastewater | Sampling for chemical and physical testing Temperature of the collected wastewater sample Range (0,5 – 50) oC |
Manual method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 95 | Water | Sampling for chemical and physical testing Temperature of the water sample taken Range (0,5 – 50) oC |
PN-ISO 5667-6:2016-02 | PN-77/C-04584 | ||
| 96 | Water | Total alkalinity Range (0,4 – 40) mmol/l Range (20 – 2000) mg/l CaCO3 |
Titrimetric method | PN-EN ISO 9963-1:2001+Ap1:2004 | |
| 97 | Water | Composite alkalinity Range (0,2 – 20) mmol/l |
Titrimetric method | PN-EN ISO 9963-1:2001+Ap1:2004 | |
| 98 | Water | Bicarbonate concentration (calculated) | PN-EN ISO 9963-1:2001+Ap1:2004 | ||
| 99 | Water | Total content of calcium and magnesium (total hardness) Range (5 – 500) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 100 | Water and wastewater | pH Range (2,0 – 12,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 101 | Water and wastewater | Electrical conductivity Range (10 – 12880) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
Reference standards (85)
EHS-PB-1 issue 5 of 17.04.2019
EHS-PB-3 issue 2 of 20.08.15
EHS-PB-43 issue 3 of 01.06.2022
EHS-PB-50 issue 1 of 05.06.2017
NIOSH Method 1003 Issue 3 (2003)
NIOSH Method 1300 Issue 2 (1994)
NIOSH Method 1400 Issue 2 (1994)
NIOSH Method 1405 Issue 1 (2003)
NIOSH Method 1450 Issue 3 (2003) EHS-PB-10 issue 5 of 29.05.2019
NIOSH Method 1457 Issue 1 (1994) EHS-PB-10 issue 5 of 29.05.2019
NIOSH Method 1458 Issue 2 (1994) EHS-PB-10 issue 5 of 29.05.2019
NIOSH Method 1500 Issue 3 (2003)
NIOSH Method 1501 Issue 3 (2003)
NIOSH Method 1551 Issue 2 (1994)
NIOSH Method 2546 Issue 1:1994
PN-75/Z-04037/03
PN-77/C-04584
PN-81/Z-04134.03
PN-83/E-04040.03
PN-C-04559-03:1972
PN-EN 14253+A1:2011
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006+Ap2:2016-04
PN-EN ISO 9377-2:2003
PN-EN ISO 9612:2011 excluding the methods covering strategies 2 and 3 – cl. 10 and 11
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-6:2016-02
PN-ISO 5667-6:2016-12
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 6439:1994, cl. 4
PN-ISO 7150-1:2002
PN-ISO 9297:1994
PN-N-01307:1994
PN-Z-01339:2020-12
PN-Z-04008-7:2002+Az1:2004
PN-Z-04041:1971
PN-Z-04108-6:2006
PN-Z-04108-6:2006/Az1:2009
PN-Z-04119-10:2008
PN-Z-04134-02:1981
PN-Z-04227-02:1992
PN-Z-04270:2000
PN-Z-04305:2003
PN-Z-04323:2004
PN-Z-04374:2009
PN-Z-04437:2011
PN-Z-04450:2014-08
PN-Z-04460:2014-09
PN-Z-04461:2015-10
PN-Z-04467:2016-10
PN-Z-04476:2016-10
PN-Z-04479:2016
PN-Z-04481:2017-10
PN-Z-04486:2017-10
PN-Z-04491:2017-10
PN-Z-04501:2019-10
PN-Z-04506:2019-10
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
PN-Z-04523:2020-12
Principles and Methods of Assessing the Working Environment 1997, No. 17, pp. 55-59
Principles and Methods of Assessing the Working Environment 1999, No. 22, pp. 96 - 100
Principles and Methods of Assessing the Working Environment 2007, No. 1 (51), pp. 141–147
Principles and Methods of Assessing the Working Environment 2009, No. 1 (59), pp. 141–146
Principles and Methods of Assessing the Working Environment 2010, No. 1 (63), pp. 155–162
Principles and Methods of Assessing the Working Environment 2016, No. 17, pp. 97-100
Principles and Methods of Assessing the Working Environment 2020, No. 2 (104), pp. 63–77
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F
based on the HACH method No. 8051