🇵🇱 „LUKSLAB” PUNKT OBSŁUGI BHP s.c. PL
Environment
„LUKSLAB” PUNKT OBSŁUGI BHP s.c. is a laboratory accredited by PCA under number AB 1225 (Lublin, Poland). Its accreditation scope covers 44 test methods in the following areas: Environment. Test objects include: Workplace environment – non-laser optical radiation, Workplace environment - air, Workplace environment – emergency lighting, General environment − noise from installations, equipment and indus…. Most frequently used techniques: Direct measurement method, Electrochemical method, Gravimetric method.
At a glance
- Accreditation number: PCA AB 1225
- Methods in scope: 44
- Types of test objects: 15
- Techniques used: 11
- City: Lublin, Poland
- Accreditation number
- AB 1225
- Accreditation body
- PCA
- Address
- Agnieszka Zarzeka, Izabela Strachecka, Joanna Korzeniowska, LABORATORIUM, ul. Plac Zamkowy 6a/7, 20-121 Lublin
- City
- Lublin, Poland
What this laboratory tests (15)
- Workplace environment – non-laser optical radiation — 9 methods
- Workplace environment - air — 8 methods
- Workplace environment – emergency lighting — 4 methods
- General environment − noise from installations, equipment and industrial plants — 2 methods
- Rooms in residential, collective residence and public utility buildings − noise — 2 methods
- Workplace environment - cold microclimate — 2 methods
- Workplace environment - hand-transmitted vibration — 2 methods
- Workplace environment - hot microclimate — 2 methods
- Workplace environment - indoor electric lighting — 2 methods
- Workplace environment - moderate microclimate — 2 methods
- Workplace environment - noise — 2 methods
- Workplace environment - outdoor electric lighting — 2 methods
- Workplace environment - whole-body vibration — 2 methods
- Workplace environment – energy expenditure — 2 methods
- Workplace environment – air – air samples collected on filters — 1 method
Analytical techniques used (11)
- Direct measurement method — 13 methods
- Electrochemical method — 2 methods
- Gravimetric method — 2 methods
- Direct measurement method (method A) — 1 method
- Direct measurement method (method M) — 1 method
- Direct measurement method (method O) — 1 method
- Direct measurement method (method X) — 1 method
- Electrochemical method * — 1 method
- Fourier transform infrared spectrometry (FT-IR) — 1 method
- Personal dosimetry method — 1 method
- Spectrometry method in the infrared range (IR) — 1 method
Certificate information
- Issue date
- 04.09.2026
- Issue no.
- 19
Accreditation scope — test methods (44)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| LABORATORY | |||||
| 1 | Rooms in residential, collective residence and public utility buildings − noise | A-weighted equivalent sound level, A-weighted maximum sound level Range (23 – 135) dB |
Direct measurement method | PN-87/B-02156 | |
| 2 | Rooms in residential, collective residence and public utility buildings − noise | A-weighted equivalent sound level for reference time T (calculated) | PN-87/B-02156 | ||
| 3 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (24 – 135) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) excluding cl. F | |
| 4 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) excluding cl. F | ||
| 5 | Workplace environment - noise | A-weighted equivalent sound level, A-weighted maximum sound level Range (24 – 135) dB C-weighted peak sound pressure level Range (46 – 138) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the methods covering strategies 2 and 3 – cl. 10 and 11 | |
| 6 | Workplace environment - noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the methods covering strategies 2 and 3 – cl. 10 and 11 | ||
| 7 | Workplace environment - air | Sampling for the assessment of occupational exposure to: dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction metals and their compounds, including – inhalable fraction – respirable fraction inorganic substances, including – inhalable fraction – respirable fraction – thoracic fraction respirable asbestos fibres respirable man-made mineral fibres excluding refractory ceramic fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres |
Personal dosimetry method | PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | |
| 8 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | ||
| 9 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction apatites and phosphorites portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range (0,15 – 17,04) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05+Ap1:2022-08 | |
| 10 | Workplace environment - air | Concentration of harmful dust agents – respirable fraction apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts diesel engine exhaust talc coal (hard, brown) Range (0,10 – 15,7) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05+Ap1:2022-08 | |
| 11 | Workplace environment – air – air samples collected on filters | Concentration / content of crystalline silica – quartz, cristobalite – respirable fraction Range (0,09 – 0,438) mg/m3 Range (0,007 – 0,400) mg in the sample |
Fourier transform infrared spectrometry (FT-IR) | Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130 | |
| 12 | Workplace environment - air | Carbon monoxide concentration Range (2,32 – 232) mg/m3 Range (2 – 200) ppm |
Electrochemical method | Test procedure PB-01 edition 4 of 09.01.2026 | |
| 13 | Workplace environment - air | Nitrogen oxide concentration Range (0,38 – 8,75) mg/m3 Range (0,3 –7,0) ppm |
Electrochemical method | Test procedure PB-05 edition 2 of 09.01.2026 | |
| 14 | Workplace environment - air | Nitrogen dioxide concentration Range (0,19 – 2,87) mg/m3 |
Electrochemical method * | Test procedure PB-05 edition 2 of 09.01.2026 | |
| 15 | Workplace environment - air | Carbon dioxide concentration Range (549,0 – 27047) mg/m3 |
Spectrometry method in the infrared range (IR) | Test procedure PB-06 edition 2 of 26.07.2026 | |
| 16 | Workplace environment - hand-transmitted vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,2 - 50) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 17 | Workplace environment - hand-transmitted vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 18 | Workplace environment - whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,04 – 50) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 19 | Workplace environment - whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 20 | Workplace environment - moderate microclimate | Air temperature Range (10 – 30) °C Black globe temperature Range (0 – 30) °C Humidity Range (25 – 75) % Air velocity Range (0,15 – 5) m/s |
Direct measurement method | PN-EN ISO 7730:2006 | |
| 21 | Workplace environment - moderate microclimate | PMV index, PPD index (calculated) | PN-EN ISO 7730:2006 | ||
| 22 | Workplace environment - hot microclimate | Air temperature Range (10 – 60) °C Natural wet bulb temperature Range (0 – 30) °C Black globe temperature Range (10 – 60) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 23 | Workplace environment - hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | ||
| 24 | Workplace environment - cold microclimate | Air temperature Range (-20 – 10) °C Black globe temperature Range (-20 – 10) °C Air humidity Range (25 – 90) % Air velocity Range (0,4 – 5) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 25 | Workplace environment - cold microclimate | IREQmin index, IREQneutral index, twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 26 | Workplace environment – energy expenditure | Air temperature Range (0 – 60) °C Air flow Range (10 – 60) dm3/min |
Test procedure PB-07 edition 2 of 03.06.2013 | ||
| 27 | Workplace environment – energy expenditure | Energy expenditure (calculated) | Test procedure PB-07 edition 2 of 03.06.2013 | ||
| 28 | Workplace environment - indoor electric lighting | Illuminance Range (5 - 10 000) lx |
Direct measurement method | Test procedure PB-02 edition 2 of 06.05.2022 | PN-83/E-04040.03 | |
| 29 | Workplace environment - indoor electric lighting | Illuminance uniformity (calculated) | Test procedure PB-02 edition 2 of 06.05.2022 | PN-83/E-04040.03 | ||
| 30 | Workplace environment - outdoor electric lighting | Illuminance Range (0,5 - 6000) lx |
Direct measurement method | Test procedure PB-02 edition 2 of 06.05.2022 | PN-83/E-04040.03 | |
| 31 | Workplace environment - outdoor electric lighting | Illuminance uniformity (calculated) | Test procedure PB-02 edition 2 of 06.05.2022 | PN-83/E-04040.03 | ||
| 32 | Workplace environment – emergency lighting | Illuminance Range (0,5 - 200) lx |
Direct measurement method | PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.5, 4.3.3, 4.3.4, 4.3.5, 4.4.3, 4.4.4, 4.4.6, 5 | |
| 33 | Workplace environment – emergency lighting | Uniformity of lighting in the high-risk area (calculated) | PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.5, 4.3.3, 4.3.4, 4.3.5, 4.4.3, 4.4.4, 4.4.6, 5 | ||
| 34 | Workplace environment – emergency lighting | Ratio of minimum to maximum illuminance (calculated) | PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.5, 4.3.3, 4.3.4, 4.3.5, 4.4.3, 4.4.4, 4.4.6, 5 | ||
| 35 | Workplace environment – emergency lighting | Closing time Range (3 – 120) s |
Direct measurement method | PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.5, 4.3.3, 4.3.4, 4.3.5, 4.4.3, 4.4.4, 4.4.6, 5 | |
| 36 | Workplace environment – non-laser optical radiation | Effective irradiance UVA, UVB and UVC in the spectral range (180 ÷ 400) nm Range (0,0 – 39,9) W/m2 |
Direct measurement method (method A) | PN-EN 14255-1:2010 | |
| 37 | Workplace environment – non-laser optical radiation | Effective radiant exposure to hazardous ultraviolet in the spectral range (180 ÷ 400) nm (calculated) | PN-EN 14255-1:2010 | ||
| 38 | Workplace environment – non-laser optical radiation | UVA irradiance in the spectral range (315 ÷ 400) nm Range (0,0 – 3999) W/m2 |
Direct measurement method (method M) | PN-EN 14255-1:2010 | |
| 39 | Workplace environment – non-laser optical radiation | Radiant exposure of UVA radiation in the spectral range (315 ÷ 400) nm (calculated) | PN-EN 14255-1:2010 | ||
| 40 | Workplace environment – non-laser optical radiation | VIS irradiance in the spectral range (300÷700) nm Range (0,0 – 399) W/m2 |
Direct measurement method (method O) | PN-EN 14255-2:2010 | |
| 41 | Workplace environment – non-laser optical radiation | Effective radiance of VIS radiation in the spectral range (300÷700) nm (calculated) | PN-EN 14255-2:2010 | ||
| 42 | Workplace environment – non-laser optical radiation | Irradiance of VIS, IRA and IRB in the spectral range (380 ÷ 3000) nm Range (0,0 – 3999) W/m2 |
Direct measurement method (method X) | PN-EN 14255-2:2010 | |
| 43 | Workplace environment – non-laser optical radiation | Irradiance of IRA and IRB in the spectral range (780 ÷ 3000) nm | Direct measurement method | PN-EN 14255-2:2010 | |
| 44 | Workplace environment – non-laser optical radiation | Radiant exposure in the spectral range (780 ÷ 3000) nm (calculated) | PN-EN 14255-2:2010 | ||
Reference standards (27)
PN-83/E-04040.03
PN-87/B-02156
PN-EN 14253+A1:2011
PN-EN 14255-1:2010
PN-EN 14255-2:2010
PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.5, 4.3.3, 4.3.4, 4.3.5, 4.4.3, 4.4.4, 4.4.6, 5
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 9612:2011 excluding the methods covering strategies 2 and 3 – cl. 10 and 11
PN-N-01307:1994
PN-Z-04008-7:2002
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05+Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05+Ap1:2022-08
Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
Test procedure PB-01 edition 4 of 09.01.2026
Test procedure PB-02 edition 2 of 06.05.2022
Test procedure PB-05 edition 2 of 09.01.2026
Test procedure PB-06 edition 2 of 26.07.2026
Test procedure PB-07 edition 2 of 03.06.2013
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) excluding cl. F