🇵🇱 INSTYTUT ŁĄCZNOŚCI - PAŃSTWOWY INSTYTUT BADAWCZY PL
Electronics & EMCEnvironment
INSTYTUT ŁĄCZNOŚCI - PAŃSTWOWY INSTYTUT BADAWCZY is a laboratory accredited by PCA under number AB 121 (Warszawa, Poland). Its accreditation scope covers 76 test methods in the following areas: Electronics & EMC, Environment. Test objects include: Radio equipment E, Electrical and electronic equipment E, Electrical and electronic equipment, Environment – electromagnetic field in the vicinity of radiocommuni….
At a glance
- Accreditation number: PCA AB 121
- Methods in scope: 76
- Types of test objects: 9
- City: Warszawa, Poland
- Accreditation number
- AB 121
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAŃ URZĄDZEŃ TELEKOMUNIKACYJNYCH (LBUT), ul. Szachowa 1, 04-894 Warszawa
- City
- Warszawa, Poland
What this laboratory tests (9)
- Radio equipment E — 51 methods
- Electrical and electronic equipment E — 14 methods
- Electrical and electronic equipment — 3 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements — 2 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations: selective measurements — 2 methods
- Audio/video, information technology and telecommunication equipment together with their power supplies — 1 method
- Electrical measuring instruments, control equipment and laboratory equipment — 1 method
- Information technology equipment and power supply equipment in telecommunications — 1 method
- Workplace environment – electromagnetic field in the workspace during operation of transmitting equipment of radiocommunication systems (mobile telephony base stations; telecommunication and radiocommunication transmitting systems) — 1 method
Certificate information
- Issue date
- 16.01.2026
- Issue no.
- 26
Accreditation scope — test methods (76)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Radio equipment E | Transmitter power (conducted signal) | Standards | ||
| 2 | Radio equipment E | Radiated power of the transmitter | |||
| 3 | Radio equipment E | Transmitter magnetic field | |||
| 4 | Radio equipment E | Transmitter electric field | |||
| 5 | Radio equipment E | Power spectral density | |||
| 6 | Radio equipment E | Frequency deviation | |||
| 7 | Radio equipment E | Frequency deviation | |||
| 8 | Radio equipment E | Power in the adjacent channel | |||
| 9 | Radio equipment E | Power in the alternate channel | |||
| 10 | Radio equipment E | Out-of-band emissions | |||
| 11 | Radio equipment E | Transmitter conducted spurious emissions | |||
| 12 | Radio equipment E | Transmitter radiated spurious emissions | |||
| 13 | Radio equipment E | Radiated emissions from the equipment enclosure | |||
| 14 | Radio equipment E | Receiver conducted spurious emissions | |||
| 15 | Radio equipment E | Receiver spurious radiations | |||
| 16 | Radio equipment E | Unwanted conducted emissions, MS with an allocated radio channel | |||
| 17 | Radio equipment E | Unwanted conducted emissions, MS in control channel tracking mode | |||
| 18 | Radio equipment E | Unwanted radiated emissions, MS with an allocated radio channel | |||
| 19 | Radio equipment E | Unwanted radiated emissions, MS in control channel tracking mode | |||
| 20 | Radio equipment E | Spurious emissions in GPRS mode in multislot configuration | |||
| 21 | Radio equipment E | Transmitter intermodulation | |||
| 22 | Radio equipment E | Transmitter switch-on time | |||
| 23 | Radio equipment E | Transmitter switch-off time | |||
| 24 | Radio equipment E | Transient states of the transmitter frequency and power | |||
| 25 | Radio equipment E | Power under transient conditions | |||
| 26 | Radio equipment E | Permissible operating frequency range | |||
| 27 | Radio equipment E | Transmitter duty cycle | |||
| 28 | Radio equipment E | Occupied bandwidth (channel) | |||
| 29 | Radio equipment E | Modulation bandwidth | |||
| 30 | Radio equipment E | Behaviour of the transmitter under reduced supply voltage conditions | |||
| 31 | Radio equipment E | Adaptive channel access mechanisms | |||
| 32 | Radio equipment E | Inhibition of the audio transmitter operation | |||
| 33 | Radio equipment E | Receiver sensitivity | Standards | ||
| 34 | Radio equipment E | Maximum usable sensitivity of the receiver (applied signal) | |||
| 35 | Radio equipment E | Maximum / average usable sensitivity of the receiver (field strength) | |||
| 36 | Radio equipment E | Co-channel selectivity / Susceptibility to co-channel interference | |||
| 37 | Radio equipment E | Adjacent channel selectivity / Susceptibility to interference in the first adjacent channel | |||
| 38 | Radio equipment E | Receiver blocking | |||
| 39 | Radio equipment E | Susceptibility to interference in the second adjacent channel | |||
| 40 | Radio equipment E | Receiver blocking in the adjacent channel | |||
| 41 | Radio equipment E | Receiver blocking susceptibility by continuous wave | |||
| 42 | Radio equipment E | Spurious response rejection | |||
| 43 | Radio equipment E | Receiver intermodulation response rejection | |||
| 44 | Radio equipment E | Blocking or desensitization | |||
| 45 | Radio equipment E | BER as a function of received signal level (RSL) | |||
| 46 | Radio equipment E | Transmission error characteristics at high input signal levels | |||
| 47 | Radio equipment E | Receiver desensitization due to simultaneous transmission and reception | |||
| 48 | Radio equipment E | Spurious response rejection in duplex operation | |||
| 49 | Radio equipment E | Control and monitoring functions of the equipment | |||
| 50 | Radio equipment E | Gain outside the operating frequency ranges | |||
| 51 | Radio equipment E | Protection against radio frequency electromagnetic radiation | |||
| 52 | Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements | Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (2 – 150) V/m - in the frequency range from 100 MHz to 60 GHz Range: (0,8 – 340) V/m Direct measurement method | …regulation of the Minister of Climate of 17.02.2020 (Journal of Laws of 2022, item 2630) | ||
| 53 | Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements | Magnetic field strength: - in the frequency range from 10 MHz to 6 GHz (calculated) - in the frequency range from 100 MHz to 60 GHz (calculated) | …regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630) | ||
| 54 | Environment – electromagnetic field in the vicinity of radiocommunication installations: selective measurements | Electric field strength: - in the frequency range from 27 MHz to 6 GHz Range: (0,05 - 200) V/m Direct measurement method with calculations | …regulation of the Minister of Climate of 17.02.2020 (Journal of Laws of 2022, item 2630) | ||
| 55 | Environment – electromagnetic field in the vicinity of radiocommunication installations: selective measurements | Magnetic field strength: - in the frequency range from 27 MHz to 6 GHz (calculated) | …regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630) | ||
| 56 | Workplace environment – electromagnetic field in the workspace during operation of transmitting equipment of radiocommunication systems (mobile telephony base stations; telecommunication and radiocommunication transmitting systems) | Electric field strength: - in the frequency range from 800 MHz to 60 GHz Range: (0,8 – 340) V/m Direct measurement method | Principles and Methods of Assessing the Working Environment, No. 2(92), 2017 pp. 89-131 | ||
| 57 | Electrical and electronic equipment E | Emission of electromagnetic disturbances | Standards | ||
| 58 | Electrical and electronic equipment E | Conducted disturbance voltage Frequency range: 9 kHz ÷ 30 MHz | |||
| 59 | Electrical and electronic equipment E | Current harmonic emissions | |||
| 60 | Electrical and electronic equipment E | Voltage changes, voltage fluctuations and flicker in public low-voltage supply systems | |||
| 61 | Electrical and electronic equipment E | Radiated disturbance field strength Frequency range: 30 MHz ÷1 GHz (GTEM cell) | |||
| 62 | Electrical and electronic equipment E | Radiated disturbance field strength Frequency range: 1 GHz ÷ 40 GHz (open area test site) | |||
| 63 | Electrical and electronic equipment E | Immunity to radiated radio-frequency electromagnetic fields Frequency range: 30 MHz ÷ 6 GHz and field strength up to 20 V/m (GTEM cell) | |||
| 64 | Electrical and electronic equipment E | Immunity to conducted disturbances induced by radio-frequency fields | |||
| 65 | Electrical and electronic equipment E | Immunity to electrostatic discharge | |||
| 66 | Electrical and electronic equipment E | Immunity to electrical fast transients/bursts | |||
| 67 | Electrical and electronic equipment E | Immunity to surges | |||
| 68 | Electrical and electronic equipment E | Immunity to power-frequency magnetic field | |||
| 69 | Electrical and electronic equipment E | Immunity to pulse magnetic field | |||
| 70 | Electrical and electronic equipment E | Immunity to voltage dips, short interruptions and voltage variations | |||
| 71 | Information technology equipment and power supply equipment in telecommunications | Features and properties for the purposes of assessing the safety of use: - marking; legibility, durability - protection against electric shock - voltages in SELV circuits and TNV circuits - limited current circuits - power of limited power sources - overcurrent protection - materials and electrical insulation class - clearances, creepage distances and distances through insulation - testing of wiring and supply cords - mechanical strength - temperature of materials and components - touch current and protective conductor current - electric strength of voltages in the cable distribution system | PN-EN 60950-1:2007+A1:2011 +A11:2009+A12:2011+A2:2014 | ||
| 72 | Audio/video, information technology and telecommunication equipment together with their power supplies | Features and properties for the purposes of assessing the safety of use: – marking, legibility, durability; – protection against electric shock; – classification of energy sources; – voltages in circuits; – overcurrent protection; – limited current circuits; – batteries; – clearances, creepage distances and distances through insulation; – electrical insulation classes; – touch current and protective conductor current; – wiring and supply cords; – operation under abnormal conditions; – temperature of materials and components; – flammability classes of materials; – mechanical strength; – mechanical stability and mechanical fixings; – enclosure classes. | PN-EN 62368-1:2015-03 +A11:2017-09 (EN 62368-1:2014 +A11:2017 | PN-EN IEC 62368-1:2020-11 +A11:2020-12 (EN IEC 62368-1:2020 +A11:2020 | …excluding cl. 9.6 | ||
| 73 | Electrical measuring instruments, control equipment and laboratory equipment | Features and properties for the purposes of assessment: – marking, durability of marking; – documentation; – protection against electric shock: under normal conditions and under single fault conditions, clearances and creepage distances, dielectric strength, mains connections and connections between parts of the equipment, – protection against mechanical hazards; – resistance to mechanical impact; – protection against the spread of fire; – limit temperature values of the equipment and resistance to heat; – protection against hazards related to fluids; – protection against radiation, including microwave radiation and laser sources, and against sound pressure; – protection against liberated gases, explosion and implosion; – protection by means of interlocks. | PN-EN 61010-1:2011 +A1:2019-04 (EN 61010-1:2010 +A1:2019 | ||
| 74 | Electrical and electronic equipment | Strength and resistance to cold (Test A) Minimum temperature – 40 ºC | EN 60068-2-1:2009 | ||
| 75 | Electrical and electronic equipment | Strength and resistance to dry heat (Test B) Maximum temperature + 85 ºC | PN-EN 60068-2-2:2009 | ||
| 76 | Electrical and electronic equipment | Strength and resistance to damp heat, steady state (Tests Ca and Cb) Humidity up to 93 % Temperature range: + 20 ºC - + 55 ºC | PN-EN 60068-2-78:2013-11 | ||
Reference standards (12)
EN 60068-2-1:2009
Standards
PN-EN 60068-2-2:2009
PN-EN 60068-2-78:2013-11
PN-EN 60950-1:2007+A1:2011 +A11:2009+A12:2011+A2:2014
PN-EN 61010-1:2011 +A1:2019-04 (EN 61010-1:2010 +A1:2019
PN-EN 62368-1:2015-03 +A11:2017-09 (EN 62368-1:2014 +A11:2017
PN-EN IEC 62368-1:2020-11 +A11:2020-12 (EN IEC 62368-1:2020 +A11:2020
Principles and Methods of Assessing the Working Environment, No. 2(92), 2017 pp. 89-131
…regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630)
…regulation of the Minister of Climate of 17.02.2020 (Journal of Laws of 2022, item 2630)
…excluding cl. 9.6