🇵🇱 WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ - KRAKÓW PL
EnvironmentWater & wastewaterMicrobiology
WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ - KRAKÓW is a laboratory accredited by PCA under number AB 1197 (Kraków, Poland). Its accreditation scope covers 54 test methods in the following areas: Environment, Water & wastewater, Microbiology. Test objects include: Water, Water (including swimming pool water), Workplace environment - air, Faeces, rectal swab. Most frequently used techniques: Direct measurement method, Membrane filtration method, Spectrophotometric method.
At a glance
- Accreditation number: PCA AB 1197
- Methods in scope: 54
- Types of test objects: 16
- Techniques used: 18
- City: Kraków, Poland
- Accreditation number
- AB 1197
- Accreditation body
- PCA
- Address
- ZESPÓŁ LABORATORYJNY, ul. Iwona Odrowąża 7, 30-901 Kraków
- City
- Kraków, Poland
What this laboratory tests (16)
- Water — 10 methods
- Water (including swimming pool water) — 6 methods
- Workplace environment - air — 6 methods
- Faeces, rectal swab — 4 methods
- Water intended for human consumption — 3 methods
- Working environment - electromagnetic field from equipment used in medical technology: - surgical diathermy units, - physiotherapy diathermy units — 3 methods
- Workplace environment – electromagnetic field in the workspace from control and measuring apparatus. — 3 methods
- Workplace environment – electromagnetic field in the workspace from hand-held and portable communication devices. — 3 methods
- Workplace environment – electromagnetic field in the workspace from mobile communication devices — 3 methods
- Workplace environment – electromagnetic field in the workspace from stationary communication devices — 3 methods
- Workplace environment – electromagnetic field in the workspace from vehicles with communication equipment — 3 methods
- Workplace environment - indoor electric lighting — 2 methods
- Workplace environment - noise — 2 methods
- Biological indicators for the control of sterilization efficacy — 1 method
- Faeces — 1 method
- and 1 more
Analytical techniques used (18)
- Direct measurement method — 14 methods
- Membrane filtration method — 5 methods
- Spectrophotometric method — 4 methods
- Culture method with biochemical confirmation — 3 methods
- Ion chromatography method — 3 methods
- Gravimetric method — 2 methods
- MPN method — 2 methods
- Plate method (pour plate) — 2 methods
- Conductometric method — 1 method
- Culture method — 1 method
- Culture method with biochemical and serological confirmation — 1 method
- Direct measurement method (simplified). — 1 method
- Gas chromatography with flame ionisation detection (GC– FID) — 1 method
- Gas chromatography with flame ionization detection (GC – FID) — 1 method
- Microscopic method — 1 method
- and 3 more
Laboratory sections (3)
- Workplace Environment Testing Laboratory — 29 methods
- Food and Water Testing Laboratory — 19 methods
- Microbiology Laboratory — 6 methods
Laboratory locations
- WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ - KRAKÓW (main site) — ul. Iwona Odrowąża 7, 30-901 Kraków
- LABORATORY TEAM — ul. Iwona Odrowąża 7
- Microbiology Laboratory — ul. Iwona Odrowąża 7, 30-901 Kraków
- Workplace Environment Testing Laboratory — ul. Iwona Odrowąża 7, 30-901 Kraków
- Food and Water Testing Laboratory — ul. Iwona Odrowąża 7, 30-901 Kraków
Certificate information
- Issue date
- 08.07.2026
- Issue no.
- 19
Accreditation scope — test methods (54)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Microbiology Laboratory | |||||
| 1 | Faeces | Presence of intestinal parasites | Microscopic method | PB-LM-02 issue 2 of 04.01.2012, based on “Standardy w zakresie laboratoryjnych czynności w parazytologii medycznej, oceny ich jakości i wartości diagnostycznej oraz laboratoryjnej interpretacji i autoryzacji wyników badań (propozycje)” (Standards for laboratory procedures in medical parasitology, assessment of their quality and diagnostic value, and laboratory interpretation and authorisation of test results – proposals), Journal of Laboratory Diagnostics 2011; 47: 341-351 | |
| 2 | Faeces, rectal swab | Presence of enteric rods of the genera Salmonella and Shigella | Culture method with biochemical and serological confirmation | PB-LM-01 issue 3 of 01.03.2016, based on the Recommendations of the National Institute of Public Health – National Institute of Hygiene and the National Chamber of Laboratory Diagnosticians | |
| 3 | Faeces, rectal swab | Presence of enteric rods of the genus Yersinia | Culture method with biochemical confirmation | PB-LM-07 issue 3 of 10.01.2019, based on the Recommendations of the National Institute of Public Health – National Institute of Hygiene and the National Chamber of Laboratory Diagnosticians | |
| 4 | Faeces, rectal swab | Presence of enteric rods of the genus Campylobacter | Culture method with biochemical confirmation | PB-LM-09 issue 3 of 10.01.2019, based on the Recommendations of the National Institute of Public Health – National Institute of Hygiene and the National Chamber of Laboratory Diagnosticians | |
| 5 | Faeces, rectal swab | Presence of enteric rods Plesiomonas shigelloides and of the genus Aeromonas. | Culture method with biochemical confirmation | PB-LM-18 issue 2 of 10.01.2019, based on the Recommendations of the National Institute of Public Health – National Institute of Hygiene and the National Chamber of Laboratory Diagnosticians | |
| 6 | Biological indicators for the control of sterilization efficacy | Presence of indicator microorganisms Geobacillus stearothermophilus, Bacillus subtilis | Culture method | PB-LM-03 issue 5. of 23.01.2023 based on the test manufacturer's instructions | |
| Workplace Environment Testing Laboratory | |||||
| 7 | Workplace environment - noise | A-weighted equivalent sound pressure level Maximum sound level A, Range (55 – 136) dB C-weighted peak sound pressure level, Range (55 – 136) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 strategy 3 - cl. 11 | |
| 8 | Workplace environment - noise | Noise exposure level with reference to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 strategy 3 - cl. 11 | ||
| 9 | Workplace environment - indoor electric lighting | Illuminance Range (10-5000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 10 | Workplace environment - indoor electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 11 | Workplace environment - air | Benzene concentration Range (0,16-40) mg/m3 |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04016-10:2005 | |
| 12 | Workplace environment - air | Toluene concentration Range (10-200) mg/m3 |
Gas chromatography with flame ionisation detection (GC– FID) | PN-Z-04115-01:1978 | |
| 13 | Workplace environment - air | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction inorganic substances, including respirable fraction organic substances, including inhalable fraction metals and their compounds, including inhalable fraction respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002 | PN-Z-04008-7:2002/AZ1:2004 | |
| 14 | Workplace environment - air | Exposure indices (calculated) | PN-Z-04008-7:2002 | PN-Z-04008-7:2002/AZ1:2004 | ||
| 15 | Workplace environment - air | Concentration of harmful dust agents inhalable fraction wood dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts Range (0,07– 20,42) mg/m3 |
Gravimetric method | PN-Z-04504:2022-05 | |
| 16 | Workplace environment - air | Concentration of harmful dust agents respirable fraction organic dusts of animal and plant origin, excluding wood and flour dusts Range (0,02 – 18,56) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | |
| 17 | Working environment - electromagnetic field from equipment used in medical technology: - surgical diathermy units, - physiotherapy diathermy units | Electric field strength in the frequency band: 10Hz – 400kHz Range 1V/m - 30kV/m in the frequency band 100 kHz – 50 GHz Range 0,5 V/m – 250 V/m |
Direct measurement method | PN-T-06580-3:2002 | Method adapted to the regulated area | IR-LBŚP-05/PO-10 issue 2 of 16.01.2020 | |
| 18 | Working environment - electromagnetic field from equipment used in medical technology: - surgical diathermy units, - physiotherapy diathermy units | Magnetic field strength in the frequency band: 10Hz – 400kHz Range 0,8 A/m - 8kA/m in the frequency band 100kHz - 1GHz Range 0,015 A/m - 8 A/m |
Direct measurement method | PN-T-06580-3:2002 | Method adapted to the regulated area | IR-LBŚP-05/PO-10 issue 2 of 16.01.2020 | |
| 19 | Working environment - electromagnetic field from equipment used in medical technology: - surgical diathermy units, - physiotherapy diathermy units | Magnetic field strength in the frequency band: 1GHz – 3GHz (calculated) |
PN-T-06580-3:2002 | Method adapted to the regulated area | IR-LBŚP-05/PO-10 issue 2 of 16.01.2020 | ||
| 20 | Workplace environment – electromagnetic field in the workspace from stationary communication devices | Electric field strength: in the frequency range from 10 Hz – 400 kHz Range 1 V/m – 50 kV/m in the frequency range from 100 kHz – 18 GHz Range (0,5 – 800) V/m in the frequency range from 27 MHz – 60 GHz Range (1 – 300) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
Direct measurement method | NO-06-A215-2:2022 | |
| 21 | Workplace environment – electromagnetic field in the workspace from stationary communication devices | Magnetic field strength from 100 kHz – 30 MHz Range (0,01 – 16) A/m from 20 MHz – 1 GHz Range (0,01 – 12) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
Direct measurement method | NO-06-A215-2:2022 | |
| 22 | Workplace environment – electromagnetic field in the workspace from stationary communication devices | Magnetic field strength from 1 GHz – 3 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
NO-06-A215-2:2022 | ||
| 23 | Workplace environment – electromagnetic field in the workspace from mobile communication devices | Electric field strength: in the frequency range from 10 Hz – 400 kHz Range 1 V/m – 50 kV/m in the frequency range from 100 kHz – 18 GHz Range (0,5 – 800) V/m in the frequency range from 27 MHz – 60 GHz Range (1 – 300) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
Direct measurement method | NO-06-A215-2:2022 | |
| 24 | Workplace environment – electromagnetic field in the workspace from mobile communication devices | Magnetic field strength from 100 kHz – 30 MHz Range (0,01 – 16) A/m from 20 MHz – 1 GHz Range (0,01 – 12) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
Direct measurement method | NO-06-A215-2:2022 | |
| 25 | Workplace environment – electromagnetic field in the workspace from mobile communication devices | Magnetic field strength from 1 GHz – 3 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
NO-06-A215-2:2022 | ||
| 26 | Workplace environment – electromagnetic field in the workspace from vehicles with communication equipment | Electric field strength: in the frequency range from 10 Hz – 400 kHz Range 1 V/m – 50 kV/m in the frequency range from 100 kHz – 18 GHz Range (0,5 – 800) V/m in the frequency range from 27 MHz – 60 GHz Range (1 – 300) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
Direct measurement method | NO-06-A215-2:2022 | |
| 27 | Workplace environment – electromagnetic field in the workspace from vehicles with communication equipment | Magnetic field strength from 100 kHz – 30 MHz Range (0,01 – 16) A/m from 20 MHz – 1 GHz Range (0,01 – 12) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
Direct measurement method | NO-06-A215-2:2022 | |
| 28 | Workplace environment – electromagnetic field in the workspace from vehicles with communication equipment | Magnetic field strength from 1 GHz – 3 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
NO-06-A215-2:2022 | ||
| 29 | Workplace environment – electromagnetic field in the workspace from hand-held and portable communication devices. | Electric field strength: in the frequency range from 10 Hz – 400 kHz Range 1 V/m – 50 kV/m in the frequency range from 100 kHz – 18 GHz Range (0,5 – 800) V/m in the frequency range from 27 MHz – 60 GHz Range (1 – 300) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
Direct measurement method | NO-06-A215-2:2022 | |
| 30 | Workplace environment – electromagnetic field in the workspace from hand-held and portable communication devices. | Magnetic field strength from 100 kHz – 30 MHz Range (0,01 – 16) A/m from 20 MHz – 1 GHz Range (0,01 – 12) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
Direct measurement method | NO-06-A215-2:2022 | |
| 31 | Workplace environment – electromagnetic field in the workspace from hand-held and portable communication devices. | Magnetic field strength from 1 GHz – 3 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
NO-06-A215-2:2022 | ||
| 32 | Workplace environment – electromagnetic field in the workspace from control and measuring apparatus. | Electric field strength: in the frequency range from 10 Hz – 400 kHz Range 1 V/m – 50 kV/m in the frequency range from 100 kHz – 18 GHz Range (0,5 – 800) V/m in the frequency range from 27 MHz – 60 GHz Range (1 – 300) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
Direct measurement method | NO-06-A215-2:2022 | |
| 33 | Workplace environment – electromagnetic field in the workspace from control and measuring apparatus. | Magnetic field strength from 100 kHz – 30 MHz Range (0,01 – 16) A/m from 20 MHz – 1 GHz Range (0,01 – 12) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
Direct measurement method | NO-06-A215-2:2022 | |
| 34 | Workplace environment – electromagnetic field in the workspace from control and measuring apparatus. | Magnetic field strength from 1 GHz – 3 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended). |
NO-06-A215-2:2022 | ||
| 35 | Workplace environment – electromagnetic field in the workspace from magnetotherapy devices | Magnetic flux density in the frequency range from 10 Hz to 400 Hz range 1 µT – 19 mT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area Confirmed competence of the laboratory taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018 item 331). |
Direct measurement method (simplified). | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| Food and Water Testing Laboratory | |||||
| 36 | Water (including swimming pool water) | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 37 | Water (including swimming pool water) | Total viable count at 22°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 38 | Water (including swimming pool water) | Total viable count at 36°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 39 | Water (including swimming pool water) | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 40 | Water (including swimming pool water) | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 41 | Water (including swimming pool water) | Most probable number of Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 42 | Water intended for human consumption | Clostridium perfringens count | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 43 | Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 | |
| 44 | Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 | |
| 45 | Water | Total iron concentration Range (0,05-0,5) mg/l |
Spectrophotometric method | PB-LBŻiW -02 issue 4 of 05.02.2020 | based on the HACH method 8008 | |
| 46 | Water | Ammonia (ammonium ion) concentration Range (0,05-1,03) mg/l |
Spectrophotometric method | PB-LBŻiW -01 issue 4 of 05.02.2020 | based on the HACH method 8038 | |
| 47 | Water | Colour Range (5 – 40) mg/l Pt |
Spectrophotometric method | PB-LBŻiW-08 issue 4 of 05.02.2020 | based on the HACH method 8025 | |
| 48 | Water | pH Range (4,0 – 10,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 49 | Water | Turbidity Range (0,10 – 20) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 50 | Water | Nitrite concentration Range (0,050-0,800) mg/l |
Spectrophotometric method | PB-LBŻiW-04 issue 5 of 05.02.2020 | based on the HACH method 8507 | |
| 51 | Water | Electrical conductivity Range (148-2500) µS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 52 | Water | Nitrate concentration Range (0,50-50) mg/l |
Ion chromatography method | PN-EN ISO 10304-1:2009+AC:2012 | |
| 53 | Water | Nitrite concentration Range (0,010-0,50) mg/l |
Ion chromatography method | PN-EN ISO 10304-1:2009+AC:2012 | |
| 54 | Water | Chloride concentration Range (5,0 -250) mg/l |
Ion chromatography method | PN-EN ISO 10304-1:2009+AC:2012 | |
Reference standards (39)
IR-LBŚP-05/PO-10 issue 2 of 16.01.2020
Method adapted to the regulated area
NO-06-A215-2:2022
PB-LBŻiW -01 issue 4 of 05.02.2020
PB-LBŻiW -02 issue 4 of 05.02.2020
PB-LBŻiW-04 issue 5 of 05.02.2020
PB-LBŻiW-08 issue 4 of 05.02.2020
PB-LM-01 issue 3 of 01.03.2016, based on the Recommendations of the National Institute of Public Health – National Institute of Hygiene and the National Chamber of Laboratory Diagnosticians
PB-LM-02 issue 2 of 04.01.2012, based on “Standardy w zakresie laboratoryjnych czynności w parazytologii medycznej, oceny ich jakości i wartości diagnostycznej oraz laboratoryjnej interpretacji i autoryzacji wyników badań (propozycje)” (Standards for laboratory procedures in medical parasitology, assessment of their quality and diagnostic value, and laboratory interpretation and authorisation of test results – proposals), Journal of Laboratory Diagnostics 2011; 47: 341-351
PB-LM-03 issue 5. of 23.01.2023 based on the test manufacturer's instructions
PB-LM-07 issue 3 of 10.01.2019, based on the Recommendations of the National Institute of Public Health – National Institute of Hygiene and the National Chamber of Laboratory Diagnosticians
PB-LM-09 issue 3 of 10.01.2019, based on the Recommendations of the National Institute of Public Health – National Institute of Hygiene and the National Chamber of Laboratory Diagnosticians
PB-LM-18 issue 2 of 10.01.2019, based on the Recommendations of the National Institute of Public Health – National Institute of Hygiene and the National Chamber of Laboratory Diagnosticians
PN-83/E-04040.03
PN-EN 27888:1999
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12/A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 strategy 3 - cl. 11
PN-N-01307:1994
PN-T-06580-3:2002
PN-Z-04008-7:2002
PN-Z-04008-7:2002/AZ1:2004
PN-Z-04016-10:2005
PN-Z-04115-01:1978
PN-Z-04504:2022-05
PN-Z-04508:2022-05
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
based on the HACH method 8008
based on the HACH method 8025
based on the HACH method 8038
based on the HACH method 8507