🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO ENERGETYKI CIEPLNEJ PL
Water & wastewaterMicrobiology
MIEJSKIE PRZEDSIĘBIORSTWO ENERGETYKI CIEPLNEJ is a laboratory accredited by PCA under number AB 1193 (Środa Wielkopolska, Poland). Its accreditation scope covers 27 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, water, Wastewater, Water, water intended for human consumption, wastewater, Water, wastewater. Most frequently used techniques: Spectrophotometric method, MPN method, Colorimetric method.
At a glance
- Accreditation number: PCA AB 1193
- Methods in scope: 27
- Types of test objects: 5
- Techniques used: 13
- City: Środa Wielkopolska, Poland
- Accreditation number
- AB 1193
- Accreditation body
- PCA
- Address
- WODOCIĄGÓW I KANALIZACJI Sp. z o.o. w Środzie Wlkp., ul. Harcerska 16, 63-000 Środa Wielkopolska, LABORATORIUM, Chwałkowo 25
- City
- Środa Wielkopolska, Poland
What this laboratory tests (5)
- Water intended for human consumption, water — 11 methods
- Wastewater — 7 methods
- Water, water intended for human consumption, wastewater — 5 methods
- Water, wastewater — 3 methods
- Water intended for human consumption — 1 method
Analytical techniques used (13)
- Spectrophotometric method — 12 methods
- MPN method — 2 methods
- Colorimetric method — 1 method
- Conductometric method — 1 method
- Electrochemical method — 1 method
- Gravimetric method — 1 method
- Manual method; Automatic method — 1 method
- Membrane filtration method — 1 method
- Nephelometric method — 1 method
- Plate method (pour plate) — 1 method
- Potentiometric method — 1 method
- Titrimetric method — 1 method
- Visual method — 1 method
Laboratory locations
- MIEJSKIE PRZEDSIĘBIORSTWO ENERGETYKI CIEPLNEJ (main site) — ul. Harcerska 16, 63-000 Środa Wielkopolska
- Laboratory; Chwałkowo 25, 63-000 Środa Wielkopolska
Certificate information
- Issue date
- 26.05.2026
- Issue no.
- 15
Accreditation scope — test methods (27)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory; Chwałkowo 25, 63-000 Środa Wielkopolska | |||||
| 1 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 excluding cl. 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6 | ||
| 2 | Water intended for human consumption, water | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 excluding cl. 10.3; 10.4;11 | ||
| 3 | Water intended for human consumption, water | Turbidity Range (0,50 – 40) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 excluding cl. 5.4 | |
| 4 | Water intended for human consumption, water | Colour Range (5 – 70) mg/l Pt |
Visual method | PN-EN ISO 7887:2012 Method D | |
| 5 | Water intended for human consumption, water | Electrical conductivity Range (5 – 3000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 6 | Water intended for human consumption, water | Free chlorine Range (0,05 – 1,50) mg/l |
Colorimetric method | PB/04 issue 1 of 02.01.2012 | |
| 7 | Water intended for human consumption, water | Manganese concentration Range (0,030 – 1,00) mg/l |
Spectrophotometric method | Hach Lange method LCW 032 issue of 11.2019 | |
| 8 | Water intended for human consumption, water | Total content of calcium and magnesium (total hardness) Range (10 - 600) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059-1999 | |
| 9 | Water intended for human consumption, water | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 10 | Water intended for human consumption, water | Most probable number, Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 11 | Water intended for human consumption, water | Total viable count at 22 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 12 | Water intended for human consumption, water | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 13 | Water, wastewater | Total phosphorus concentration Range (0,050 – 2,00) mg/l Phosphate concentration Range (0,150 – 5,00) mg/l |
Spectrophotometric method | PB/02 issue 1 of 01.12.2017 | based on the Hach Lange method LCK 349 | |
| 14 | Water, wastewater | Ammonium ion concentration Range (2,50 – 60,0) mg/l Ammonium nitrogen concentration Range (2,00 – 47,0) mg/l |
Spectrophotometric method | Hach Lange method LCK 303 issue of 10.2019 | |
| 15 | Water, wastewater | Iron concentration Range (0,200 – 6,00) mg/l |
Spectrophotometric method | Hach Lange method LCK 321 issue of 07.2019 | |
| 16 | Wastewater | Sampling for chemical and physical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | |
| 17 | Wastewater | Chemical oxygen demand - COD-Cr Range (15,0 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 18 | Wastewater | Biochemical oxygen demand BOD5 Range (1 – 6 000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 19 | Wastewater | Total suspended solids (TSS) Range (3,0 – 3000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 20 | Wastewater | Total nitrogen concentration Range (1,00 – 500) mg/l |
Spectrophotometric method | PB/06 issue 2 of 01.12.2017 based on the Hach Lange method LCK 138 and LCK 338 | |
| 21 | Wastewater | Ammonium nitrogen concentration Range (47,0 – 130) mg/l |
Spectrophotometric method | Hach Lange method LCK 302 issue of 10.2019 | |
| 22 | Wastewater | Total phosphorus concentration Range (2,00 – 60,0) mg/l |
Spectrophotometric method | PB/01 issue 01 of 01.12.2017 based on the Hach Lange method LCK 350 | |
| 23 | Water, water intended for human consumption, wastewater | Ammonium ion concentration Range (0,050 – 2,50) mg/l Ammonium nitrogen concentration Range (0,039 – 2,00) mg/l |
Spectrophotometric method | Hach Lange method LCK 304 issue of 10.2019 | |
| 24 | Water, water intended for human consumption, wastewater | Nitrate concentration Range (1,00 – 60,0) mg/l Nitrate nitrogen concentration Range (0,230 – 13,5) mg/l |
Spectrophotometric method | Hach Lange method LCK 339 issue of 10.2019 | |
| 25 | Water, water intended for human consumption, wastewater | Nitrite concentration Range (0,050 – 2,00) mg/l Nitrite nitrogen concentration Range (0,015 – 0,600) mg/l |
Spectrophotometric method | Hach Lange method LCK 341 issue of 10.2019 | |
| 26 | Water, water intended for human consumption, wastewater | Iron concentration Range (0,100 – 1,00) mg/l |
Spectrophotometric method | Hach Lange method LCK 521 issue of 06.2019 | |
| 27 | Water, water intended for human consumption, wastewater | pH Range 4,0 –10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
Reference standards (27)
Hach Lange method LCK 302 issue of 10.2019
Hach Lange method LCK 303 issue of 10.2019
Hach Lange method LCK 304 issue of 10.2019
Hach Lange method LCK 321 issue of 07.2019
Hach Lange method LCK 339 issue of 10.2019
Hach Lange method LCK 341 issue of 10.2019
Hach Lange method LCK 521 issue of 06.2019
Hach Lange method LCW 032 issue of 11.2019
PB/01 issue 01 of 01.12.2017 based on the Hach Lange method LCK 350
PB/02 issue 1 of 01.12.2017
PB/04 issue 1 of 02.01.2012
PB/06 issue 2 of 01.12.2017 based on the Hach Lange method LCK 138 and LCK 338
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 excluding cl. 4.4.2; 4.4.3; 4.4.4; 4.4.5; 4.4.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09 excluding cl. 5.4
PN-EN ISO 7887:2012 Method D
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10 excluding cl. 10.3; 10.4;11
PN-ISO 6059-1999
based on the Hach Lange method LCK 349