🇵🇱 RADMOR S.A. PL
Electronics & EMC
RADMOR S.A. is a laboratory accredited by PCA under number AB 1132 (Gdynia, Poland). Its accreditation scope covers 53 test methods in the following areas: Electronics & EMC. Test objects include: Military equipment. Electrical, telecommunications and electronic p…, Military equipment. Electrical, telecommunications and electronic p…, Military equipment. Electrical, telecommunications and electronic p…, Military equipment. Electrical, telecommunications and electronic p…. Most frequently used techniques: Measurement in a 3 m SAC chamber, Direct measurement method, Method: single chamber.
At a glance
- Accreditation number: PCA AB 1132
- Methods in scope: 53
- Types of test objects: 10
- Techniques used: 4
- City: Gdynia, Poland
- Accreditation number
- AB 1132
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAWCZE, ul. Hutnicza 3, 81-212 Gdynia
- City
- Gdynia, Poland
What this laboratory tests (10)
- Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. — 14 methods
- Military equipment. Electrical, telecommunications and electronic products and equipment. — 13 methods
- Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. — 6 methods
- Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm — 6 methods
- Electrical, telecommunications and electronic products and equipment. — 5 methods
- Electrical, telecommunications and electronic products and equipment — 3 methods
- Military equipment. Electrical, telecommunication and electronic products and equipment — 2 methods
- Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions up to: 50 cm x 50 cm x 50 cm — 2 methods
- Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Dimensions: 67 cm x 67 cm x 20 cm — 1 method
- Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions: - horizontal cross-section Ǿ50 cm. — 1 method
Analytical techniques used (4)
- Measurement in a 3 m SAC chamber — 2 methods
- Direct measurement method — 1 method
- Method: single chamber. — 1 method
- Method: two chambers — 1 method
Laboratory sections (2)
- Radiocommunication and Electromagnetic Compatibility Testing Laboratory — 37 methods
- Environmental Testing Laboratory — 16 methods
Laboratory locations
- RADMOR S.A. (main site) — ul. Hutnicza 3, 81-212 Gdynia
- TESTING LABORATORY — ul. Hutnicza 3
- Radiocommunication and Electromagnetic Compatibility Testing Laboratory — ul. Hutnicza 3, 81-212 Gdynia
- Environmental Testing Laboratory — ul. Hutnicza 3, 81-212 Gdynia
Certificate information
- Issue date
- 12.10.2026
- Issue no.
- 19
Accreditation scope — test methods (53)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Radiocommunication and Electromagnetic Compatibility Testing Laboratory | |||||
| 1 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Frequency deviation Range up to 1 GHz |
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.1 | ||
| 2 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Carrier power (conducted) Range up to 1 GHz |
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.2 | ||
| 3 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Frequency deviation Range up to 1 GHz |
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.4 | ||
| 4 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Adjacent channel power Range up to 1 GHz |
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.5 | ||
| 5 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Transmitter spurious emissions (power level into a defined load) Range up to 12,75 GHz |
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.6.2 | ||
| 6 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Conducted emissions, antenna terminals Range from 10 kHz to 40 GHz |
NO-06-A500:2012 (cl. 3.3 procedure PCE-03) | MIL-STD 461F (procedure CE106) | MIL-STD 461G (procedure CE106) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.13 (procedure NCE03) | ||
| 7 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Intermodulation attenuation Range up to 0,5 GHz |
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.7 | ||
| 8 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Maximum usable sensitivity (applied signal) Range up to 1 GHz |
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.1 | ||
| 9 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Co-channel rejection Range up to 1 GHz |
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.3 | ||
| 10 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Adjacent channel selectivity Range up to 1 GHz |
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.4 | ||
| 11 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Selectivity against signals at unwanted frequencies Range up to 2 GHz |
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.5 | ||
| 12 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Immunity to intermodulation interference Range up to 1 GHz |
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.6 | ||
| 13 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Blocking or desensitization Range up to 1 GHz |
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.7 | ||
| 14 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Spurious emissions (Conducted emission) Range up to 12,75 GHz |
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.8.2 | ||
| 15 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Conducted disturbance voltage at the mains terminals and telecommunication ports Frequency range From 150 kHz to 30 MHz |
PN-EN 55022:2011, cl. 9 | PN-EN 55032:2015-09 | PN-EN 55016-2-1:2014-09 | ||
| 16 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Conducted emissions, power supply leads Range from 10 kHz to 10 MHz |
NO-06-A500:2012 (cl. 3.2 procedure PCE-02) | MIL-STD 461F (procedure CE102) | MIL-STD 461G (procedure CE102) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.12 (procedure NCE02) | ||
| 17 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Level of radiated disturbances, electric field Frequency range From 10 kHz to 18 GHz |
NO-06-A500:2012, cl. 3.14 (procedure PRE-02) | MIL-STD 461F (procedure RE102) | MIL-STD 461G (procedure RE102) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.30 (procedure NRE02) | NO-A-STANAG-4370/AECTP-500-2:2021 cl. 3.12 (procedure NRE02.2) | ||
| 18 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Radiated emissions Frequency range From 30 MHz to 6 GHz |
Measurement in a 3 m SAC chamber | PN-EN 55022:2011, cl. 10 | PN-EN 55032:2015-09 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 55016-2-3:2017-06/A2:2024-03 | |
| 19 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Conducted susceptibility, power leads Frequency range from 30 Hz to 150 kHz |
NO-06-A500:2012 cl. 3.4 (procedure PCS-01) | MIL-STD 461F (procedure CS101) | MIL-STD 461G (procedure CS101) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.16 (procedure NCS01) | ||
| 20 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Conducted susceptibility, all power and signal cables. Frequency range From 4 kHz to 200 MHz |
Direct measurement method | NO-06-A500:2012 cl. 3.9 (procedure PCS-06) | MIL-STD 461F (procedure CS114) | MIL-STD 461G (procedure CS114) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.22 (procedure NCS07) | |
| 21 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Immunity to conducted disturbances induced by radio-frequency fields. Frequency range From 150 kHz to 80 MHz |
PN-EN 61000-4-6:2014-04 | PN-EN 61000-4-6:2024-03 | PN-EN 55016-2-4:2005 | ||
| 22 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Immunity to conducted disturbances, impulse excitation | NO-06-A500:2012 cl. 3.10 (procedure PCS-07) | MIL-STD 461F (procedure CS115) | MIL-STD 461G (procedure CS115) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.23 (procedure NCS08) | ||
| 23 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Conducted susceptibility, damped sinusoidal transients, power and signal leads Frequency range from 10 kHz to 100 MHz |
NO-06-A500:2012 cl. 3.11 (procedure PCS-08) | MIL-STD 461F (procedure CS116) | MIL-STD 461G (procedure CS116) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.24 (procedure NCS09) | ||
| 24 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Radiated susceptibility, magnetic field Frequency range from 30 Hz to 100 kHz |
NO-06-A500:2012 cl. 3.16 (procedure PRS-01) | MIL-STD 461F (procedure RS101) | MIL-STD 461G (procedure RS101) | NO-A-STANAG-4370/AECTP-500- 1:2021 cl. 3.32 (procedure NRS01) | NO-A-STANAG-4370/AECTP-500- 2:2021 cl. 3.13 (procedure NRS01.2) | ||
| 25 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Immunity to radiated disturbances, electric field Frequency range from 2 MHz to 18 GHz |
NO-06-A500:2012 cl. 3.17 (procedure PRS-02) | MIL-STD 461F (procedure RS103) | MIL-STD 461G (procedure RS103) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.33 (procedure NRS02) | NO-A-STANAG-4370/AECTP-500-2:2021 cl. 3.14 (procedure NRS02.2) | ||
| 26 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Radiated radio-frequency electromagnetic field immunity test | Measurement in a 3 m SAC chamber | PN-EN 61000-4-3:2021-06 | PN-EN 55016-2-4:2005 | |
| 27 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Immunity to electrostatic discharge Ranges up to ±15 kV (contact discharges) Ranges up to ±30 kV (air discharges) |
PN-EN 61000-4-2:2011 | MIL-STD 461G (procedure CS118) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.27 (procedure NCS12) | NO-A-STANAG-4370/AECTP-500-2:2021 cl. 3.10 (procedure NCS12.2) | ||
| 28 | Electrical, telecommunications and electronic products and equipment. | Surge immunity 1,2/50 µs, 8/20 µs for power supply ports | PN-EN 61000-4-5:2014-10 | ||
| 29 | Electrical, telecommunications and electronic products and equipment. | Surge immunity 1,2/50 µs, 8/20 µs for signal and control ports | PN-EN 61000-4-5:2014-10 | ||
| 30 | Electrical, telecommunications and electronic products and equipment. | Electrical fast transient/burst immunity, Power supply port Range 5,5 kV |
PN-EN 61000-4-4:2013-05 | ||
| 31 | Electrical, telecommunications and electronic products and equipment. | Electrical fast transient/burst immunity, Signal and control port Range up to 2 kV |
PN-EN 61000-4-4:2013-05 | ||
| 32 | Electrical, telecommunications and electronic products and equipment. | Immunity to voltage dips, short interruptions and voltage variations Voltage dips 0 %, 40 %, 70 %, 80 % Voltage interruptions 0% |
PN-EN 61000-4-11:2020-11 | ||
| 33 | Military equipment. Electrical, telecommunication and electronic products and equipment | Electrical insulation resistance R from 50 kΩ to 200 GΩ Umeas (10 – 1000) VDC |
NO-06-A108:2005, cl. 3.2 | NO-06-A108:2021, cl. 3.2 | ||
| 34 | Military equipment. Electrical, telecommunication and electronic products and equipment | Dielectric strength of the insulation Up (0 - 5) kVAC Up (0 - 6) kVDC |
NO-06-A108:2005, cl. 3.3 | NO-06-A108:2021, cl. 3.3 | ||
| 35 | Electrical, telecommunications and electronic products and equipment | Immunity to power-frequency magnetic field | PN-EN 61000-4-8:2010 | ||
| 36 | Electrical, telecommunications and electronic products and equipment | Permissible levels of current harmonic emissions | PN-EN IEC 61000-3-2:2019-04 | PN-EN 61000-3-12:2012 | PN-EN 61000-3-12:2012/A1:2024-11 | ||
| 37 | Electrical, telecommunications and electronic products and equipment | Voltage fluctuations and flicker in public low-voltage supply systems, caused by equipment with rated phase current 32 A | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN 61000-3-11:2020 -01 | ||
| Environmental Testing Laboratory | |||||
| 38 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm | Strength, resistance, total resistance to low temperature Minimum temperature -60 °C. |
PN-EN 60068-2-1: 2009 | NO-06-A107:2005, cl. 4.3, 5.6 | NO-06-A107:2021, cl. 4.3, 5.6 | MIL-STD 810F, Method 502.4, procedures I and II | NO-A-STANAG-4370/AECTP-300-3:2022 | ||
| 39 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm | Strength, resistance, total resistance to high temperature maximum temperature +170 °C minimum relative humidity 20 %. |
PN-EN 60068-2-2:2009 | NO-06-A107:2005, cl. 4.2, 5.7 | NO-06-A107:2021, cl. 4.2, 5.7 | MIL-STD 810F, Method 501.4, procedures I and II | NO-A-STANAG-4370/AECTP-300-2:2022 | ||
| 40 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm | Strength, resistance, total resistance to damp heat, steady state/cyclic relative humidity up to 95 % temp. from +20 °C to +85 °C |
PN-EN 60068-2-30:2008 | PN-EN 60068-2-78:2013-11 | NO-06-A107:2005, cl. 4.4, Methods 1, 2 and Method 3, cl. 5.10 | NO-06-A107:2021, cl. 4.4, Methods 1, 2 and Method 3, cl. 5.10 | MIL-STD 810F, Method 507.4 | NO-A-STANAG-4370/AECTP-300-6:2022 | ||
| 41 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm | Strength and resistance to temperature changes temp. min. -60 °C max. temp. +170 °C. |
Method: single chamber. | PN-EN IEC 60068-2-14:2024-04, test Nb | PN-EN 60068-2-14:2009, test Nb | NO-06-A107:2005, cl. 4.5, Method 2, cl. 5.9 | NO-06-A107:2021, cl. 4.5, Method 2, cl. 5.9 | |
| 42 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm | Strength and resistance to temperature changes temp. min. -60 °C max. temp. +170 °C. |
Method: two chambers | PN-EN IEC 60068-2-14:2024-04, test Na | PN-EN 60068-2-14:2009, test Na | NO-06-A107:2005, cl. 4.5, Method 1, cl. 5.8 | NO-06-A107:2021, cl. 4.5, Method 1, cl. 5.8 | MIL-STD 810F, Method 503.4, procedures I and II | NO-A-STANAG-4370/AECTP-300-4:2022 | |
| 43 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm | Resistance to condensation atmospheric deposits (frost and dew) | NO-06–A107:2005 + A1:2017, cl. 4.10. | NO-06–A107:2021, cl. 4.10. | ||
| 44 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. | Mechanical resonances of the structure. frequency (5 – 40) Hz. |
NO-06-A107:2005, cl. 2.2 | NO-06-A107:2021, cl. 2.2 | ||
| 45 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. | Strength, resistance, total resistance to sinusoidal mechanical vibrations Frequency (1 – 3000) Hz |
PN-EN 60068-2-6:2008 | NO-06-A107:2005, cl. 2.3, 2.7, 2.12, 3.2 | NO-06-A107:2021, cl. 2.3, 2.7, 2.12, 3.2 | MIL-STD 810F, Method 514.5, procedure I | ||
| 46 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. | Strength, resistance, total resistance to mechanical shocks (half-sine / trapezoidal). Peak acceleration amplitude respectively up to 1500 m/s² Surge duration (1 - 50) ms. Repetition frequency up to 3 Hz. |
PN-EN 60068-2-27:2009 | NO-06-A107:2005, cl. 2.5, 2.9, 2.13, 3.4 | NO-06-A107:2021, cl. 2.5, 2.9, 2.13, 3.4 | ||
| 47 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. | Strength, resistance, total resistance to broadband random vibrations Frequency (10 – 2000) Hz Root mean square value GRMS up to 30 gn. |
PN-EN 60068-2-64:2008 | NO-06-A107:2005, cl. 2.4, 2.8 | NO-06-A107:2021, cl. 2.4, 2.8 | MIL-STD- 810F, Method 514.5 | ||
| 48 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. | Overall strength and resistance to transport | NO-06-A107:2005, cl. 2.10 | NO-06-A107:2021, cl. 2.10 | ||
| 49 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. | Resistance to free falls, drops and topples | PN-EN 60068-2-31:2010 | NO-06-A107:2005, cl. 2.11 | NO-06-A107:2021, cl. 2.11 | MIL-STD 810F, Method 516.5, procedure IV | ||
| 50 | Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions: - horizontal cross-section Ǿ50 cm. | Hermeticity. Resistance to immersion in water Code IPX7 – IPX8 |
PN-EN 60529:2003, cl. 14.2.7 and 14.2.8 | NO-06-A107:2005, cl. 4.16, Method 2 | NO-06-A107:2021, cl. 4.16, Method 2 | MIL-STD 810F, Method 512.4, procedure I | NO-A-STANAG-4370/AECTP-300-7:2022 | ||
| 51 | Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions up to: 50 cm x 50 cm x 50 cm | Splash-proofness Code IPX3 - IPX4 |
PN-EN 60529:2003, cl. 14.2.3 and cl. 14.2.4 | PN-EN 60529:2003/A2:2014-07 | ||
| 52 | Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions up to: 50 cm x 50 cm x 50 cm | Strength and resistance to rain (drip-proofness) Code IPX1 – IPX2 |
PN-EN 60529:2003, cl. 14.2.1 and cl. 14.2.2 | PN-EN 60529:2003/A2:2014-07 | NO-06-A107:2005, cl. 4.18 | NO-06-A107:2021, cl. 4.18 | MIL-STD 810F, Method 506.4, procedure III | ||
| 53 | Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Dimensions: 67 cm x 67 cm x 20 cm | Strength and resistance to dust (dust-tightness) Code IP5X |
PN-EN 60529:2003, cl. 13.4 and 13.5, category 2 | NO-06-A107:2005, cl. 4.12, Method 2, cl. 5.15 | NO-06-A107:2021, cl. 4.12, Method 2, cl. 5.15 | ||
Reference standards (144)
MIL-STD 461F (procedure CE102)
MIL-STD 461F (procedure CE106)
MIL-STD 461F (procedure CS101)
MIL-STD 461F (procedure CS114)
MIL-STD 461F (procedure CS115)
MIL-STD 461F (procedure CS116)
MIL-STD 461F (procedure RE102)
MIL-STD 461F (procedure RS101)
MIL-STD 461F (procedure RS103)
MIL-STD 461G (procedure CE102)
MIL-STD 461G (procedure CE106)
MIL-STD 461G (procedure CS101)
MIL-STD 461G (procedure CS114)
MIL-STD 461G (procedure CS115)
MIL-STD 461G (procedure CS116)
MIL-STD 461G (procedure CS118)
MIL-STD 461G (procedure RE102)
MIL-STD 461G (procedure RS101)
MIL-STD 461G (procedure RS103)
MIL-STD 810F, Method 501.4, procedures I and II
MIL-STD 810F, Method 502.4, procedures I and II
MIL-STD 810F, Method 503.4, procedures I and II
MIL-STD 810F, Method 506.4, procedure III
MIL-STD 810F, Method 507.4
MIL-STD 810F, Method 512.4, procedure I
MIL-STD 810F, Method 514.5, procedure I
MIL-STD 810F, Method 516.5, procedure IV
MIL-STD- 810F, Method 514.5
NO-06-A107:2005, cl. 2.10
NO-06-A107:2005, cl. 2.11
NO-06-A107:2005, cl. 2.2
NO-06-A107:2005, cl. 2.3, 2.7, 2.12, 3.2
NO-06-A107:2005, cl. 2.4, 2.8
NO-06-A107:2005, cl. 2.5, 2.9, 2.13, 3.4
NO-06-A107:2005, cl. 4.12, Method 2, cl. 5.15
NO-06-A107:2005, cl. 4.16, Method 2
NO-06-A107:2005, cl. 4.2, 5.7
NO-06-A107:2005, cl. 4.3, 5.6
NO-06-A107:2005, cl. 4.4, Methods 1, 2 and Method 3, cl. 5.10
NO-06-A107:2005, cl. 4.5, Method 1, cl. 5.8
NO-06-A107:2005, cl. 4.5, Method 2, cl. 5.9
NO-06-A107:2005, cl. 4.18
NO-06-A107:2021, cl. 2.10
NO-06-A107:2021, cl. 2.11
NO-06-A107:2021, cl. 2.2
NO-06-A107:2021, cl. 2.3, 2.7, 2.12, 3.2
NO-06-A107:2021, cl. 2.4, 2.8
NO-06-A107:2021, cl. 2.5, 2.9, 2.13, 3.4
NO-06-A107:2021, cl. 4.12, Method 2, cl. 5.15
NO-06-A107:2021, cl. 4.16, Method 2
NO-06-A107:2021, cl. 4.2, 5.7
NO-06-A107:2021, cl. 4.3, 5.6
NO-06-A107:2021, cl. 4.4, Methods 1, 2 and Method 3, cl. 5.10
NO-06-A107:2021, cl. 4.5, Method 1, cl. 5.8
NO-06-A107:2021, cl. 4.5, Method 2, cl. 5.9
NO-06-A107:2021, cl. 4.18
NO-06-A108:2005, cl. 3.2
NO-06-A108:2005, cl. 3.3
NO-06-A108:2021, cl. 3.2
NO-06-A108:2021, cl. 3.3
NO-06-A500:2012 (cl. 3.2 procedure PCE-02)
NO-06-A500:2012 (cl. 3.3 procedure PCE-03)
NO-06-A500:2012 cl. 3.10 (procedure PCS-07)
NO-06-A500:2012 cl. 3.11 (procedure PCS-08)
NO-06-A500:2012 cl. 3.16 (procedure PRS-01)
NO-06-A500:2012 cl. 3.17 (procedure PRS-02)
NO-06-A500:2012 cl. 3.4 (procedure PCS-01)
NO-06-A500:2012 cl. 3.9 (procedure PCS-06)
NO-06-A500:2012, cl. 3.14 (procedure PRE-02)
NO-06–A107:2005 + A1:2017, cl. 4.10.
NO-06–A107:2021, cl. 4.10.
NO-A-STANAG-4370/AECTP-300-2:2022
NO-A-STANAG-4370/AECTP-300-3:2022
NO-A-STANAG-4370/AECTP-300-4:2022
NO-A-STANAG-4370/AECTP-300-6:2022
NO-A-STANAG-4370/AECTP-300-7:2022
NO-A-STANAG-4370/AECTP-500- 1:2021 cl. 3.32 (procedure NRS01)
NO-A-STANAG-4370/AECTP-500- 2:2021 cl. 3.13 (procedure NRS01.2)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.12 (procedure NCE02)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.13 (procedure NCE03)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.16 (procedure NCS01)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.22 (procedure NCS07)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.23 (procedure NCS08)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.24 (procedure NCS09)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.27 (procedure NCS12)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.30 (procedure NRE02)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.33 (procedure NRS02)
NO-A-STANAG-4370/AECTP-500-2:2021 cl. 3.10 (procedure NCS12.2)
NO-A-STANAG-4370/AECTP-500-2:2021 cl. 3.12 (procedure NRE02.2)
NO-A-STANAG-4370/AECTP-500-2:2021 cl. 3.14 (procedure NRS02.2)
PN-EN 55016-2-1:2014-09
PN-EN 55016-2-3:2017-06
PN-EN 55016-2-3:2017-06/A1:2020-01
PN-EN 55016-2-3:2017-06/A2:2024-03
PN-EN 55016-2-4:2005
PN-EN 55022:2011, cl. 10
PN-EN 55022:2011, cl. 9
PN-EN 55032:2015-09
PN-EN 60068-2-14:2009, test Na
PN-EN 60068-2-14:2009, test Nb
PN-EN 60068-2-1: 2009
PN-EN 60068-2-27:2009
PN-EN 60068-2-2:2009
PN-EN 60068-2-30:2008
PN-EN 60068-2-31:2010
PN-EN 60068-2-64:2008
PN-EN 60068-2-6:2008
PN-EN 60068-2-78:2013-11
PN-EN 60529:2003, cl. 13.4 and 13.5, category 2
PN-EN 60529:2003, cl. 14.2.1 and cl. 14.2.2
PN-EN 60529:2003, cl. 14.2.3 and cl. 14.2.4
PN-EN 60529:2003, cl. 14.2.7 and 14.2.8
PN-EN 60529:2003/A2:2014-07
PN-EN 61000-3-11:2020 -01
PN-EN 61000-3-12:2012
PN-EN 61000-3-12:2012/A1:2024-11
PN-EN 61000-3-3:2013-10
PN-EN 61000-3-3:2013-10/A1:2019-10
PN-EN 61000-3-3:2013-10/A2:2022-04
PN-EN 61000-3-3:2013-10/AC:2022-05
PN-EN 61000-4-11:2020-11
PN-EN 61000-4-2:2011
PN-EN 61000-4-3:2021-06
PN-EN 61000-4-4:2013-05
PN-EN 61000-4-5:2014-10
PN-EN 61000-4-6:2014-04
PN-EN 61000-4-6:2024-03
PN-EN 61000-4-8:2010
PN-EN IEC 60068-2-14:2024-04, test Na
PN-EN IEC 60068-2-14:2024-04, test Nb
PN-EN IEC 61000-3-2:2019-04
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.1
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.2
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.4
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.5
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.6.2
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.7
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.1
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.3
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.4
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.5
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.6
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.7
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.8.2