🇵🇱 RADMOR S.A. PL

PCA AB 1132 • Gdynia, Poland • 53 methods

Electronics & EMC

RADMOR S.A. is a laboratory accredited by PCA under number AB 1132 (Gdynia, Poland). Its accreditation scope covers 53 test methods in the following areas: Electronics & EMC. Test objects include: Military equipment. Electrical, telecommunications and electronic p…, Military equipment. Electrical, telecommunications and electronic p…, Military equipment. Electrical, telecommunications and electronic p…, Military equipment. Electrical, telecommunications and electronic p…. Most frequently used techniques: Measurement in a 3 m SAC chamber, Direct measurement method, Method: single chamber.

At a glance

  • Accreditation number: PCA AB 1132
  • Methods in scope: 53
  • Types of test objects: 10
  • Techniques used: 4
  • City: Gdynia, Poland
Accreditation number
AB 1132
Accreditation body
PCA
Address
LABORATORIUM BADAWCZE, ul. Hutnicza 3, 81-212 Gdynia
City
Gdynia, Poland

What this laboratory tests (10)

Analytical techniques used (4)

Laboratory sections (2)

Laboratory locations

Certificate information

Issue date
12.10.2026
Issue no.
19

Accreditation scope — test methods (53)

No. Test object Methodology / Parameters Technique Reference document
Radiocommunication and Electromagnetic Compatibility Testing Laboratory
1 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Frequency deviation
Range up to 1 GHz
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.1
2 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Carrier power (conducted)
Range up to 1 GHz
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.2
3 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Frequency deviation
Range up to 1 GHz
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.4
4 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Adjacent channel power
Range up to 1 GHz
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.5
5 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Transmitter spurious emissions (power level into a defined load)
Range up to 12,75 GHz
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.6.2
6 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Conducted emissions, antenna terminals
Range from 10 kHz to 40 GHz
NO-06-A500:2012 (cl. 3.3 procedure PCE-03) | MIL-STD 461F (procedure CE106) | MIL-STD 461G (procedure CE106) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.13 (procedure NCE03)
7 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Intermodulation attenuation
Range up to 0,5 GHz
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.7
8 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Maximum usable sensitivity (applied signal)
Range up to 1 GHz
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.1
9 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Co-channel rejection
Range up to 1 GHz
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.3
10 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Adjacent channel selectivity
Range up to 1 GHz
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.4
11 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Selectivity against signals at unwanted frequencies
Range up to 2 GHz
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.5
12 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Immunity to intermodulation interference
Range up to 1 GHz
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.6
13 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Blocking or desensitization
Range up to 1 GHz
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.7
14 Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Spurious emissions (Conducted emission)
Range up to 12,75 GHz
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.8.2
15 Military equipment. Electrical, telecommunications and electronic products and equipment. Conducted disturbance voltage at the mains terminals and telecommunication ports
Frequency range From 150 kHz to 30 MHz
PN-EN 55022:2011, cl. 9 | PN-EN 55032:2015-09 | PN-EN 55016-2-1:2014-09
16 Military equipment. Electrical, telecommunications and electronic products and equipment. Conducted emissions, power supply leads
Range from 10 kHz to 10 MHz
NO-06-A500:2012 (cl. 3.2 procedure PCE-02) | MIL-STD 461F (procedure CE102) | MIL-STD 461G (procedure CE102) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.12 (procedure NCE02)
17 Military equipment. Electrical, telecommunications and electronic products and equipment. Level of radiated disturbances, electric field
Frequency range From 10 kHz to 18 GHz
NO-06-A500:2012, cl. 3.14 (procedure PRE-02) | MIL-STD 461F (procedure RE102) | MIL-STD 461G (procedure RE102) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.30 (procedure NRE02) | NO-A-STANAG-4370/AECTP-500-2:2021 cl. 3.12 (procedure NRE02.2)
18 Military equipment. Electrical, telecommunications and electronic products and equipment. Radiated emissions
Frequency range From 30 MHz to 6 GHz
Measurement in a 3 m SAC chamber PN-EN 55022:2011, cl. 10 | PN-EN 55032:2015-09 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 55016-2-3:2017-06/A2:2024-03
19 Military equipment. Electrical, telecommunications and electronic products and equipment. Conducted susceptibility, power leads
Frequency range from 30 Hz to 150 kHz
NO-06-A500:2012 cl. 3.4 (procedure PCS-01) | MIL-STD 461F (procedure CS101) | MIL-STD 461G (procedure CS101) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.16 (procedure NCS01)
20 Military equipment. Electrical, telecommunications and electronic products and equipment. Conducted susceptibility, all power and signal cables.
Frequency range From 4 kHz to 200 MHz
Direct measurement method NO-06-A500:2012 cl. 3.9 (procedure PCS-06) | MIL-STD 461F (procedure CS114) | MIL-STD 461G (procedure CS114) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.22 (procedure NCS07)
21 Military equipment. Electrical, telecommunications and electronic products and equipment. Immunity to conducted disturbances induced by radio-frequency fields.
Frequency range From 150 kHz to 80 MHz
PN-EN 61000-4-6:2014-04 | PN-EN 61000-4-6:2024-03 | PN-EN 55016-2-4:2005
22 Military equipment. Electrical, telecommunications and electronic products and equipment. Immunity to conducted disturbances, impulse excitation NO-06-A500:2012 cl. 3.10 (procedure PCS-07) | MIL-STD 461F (procedure CS115) | MIL-STD 461G (procedure CS115) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.23 (procedure NCS08)
23 Military equipment. Electrical, telecommunications and electronic products and equipment. Conducted susceptibility, damped sinusoidal transients, power and signal leads
Frequency range from 10 kHz to 100 MHz
NO-06-A500:2012 cl. 3.11 (procedure PCS-08) | MIL-STD 461F (procedure CS116) | MIL-STD 461G (procedure CS116) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.24 (procedure NCS09)
24 Military equipment. Electrical, telecommunications and electronic products and equipment. Radiated susceptibility, magnetic field
Frequency range from 30 Hz to 100 kHz
NO-06-A500:2012 cl. 3.16 (procedure PRS-01) | MIL-STD 461F (procedure RS101) | MIL-STD 461G (procedure RS101) | NO-A-STANAG-4370/AECTP-500- 1:2021 cl. 3.32 (procedure NRS01) | NO-A-STANAG-4370/AECTP-500- 2:2021 cl. 3.13 (procedure NRS01.2)
25 Military equipment. Electrical, telecommunications and electronic products and equipment. Immunity to radiated disturbances, electric field
Frequency range from 2 MHz to 18 GHz
NO-06-A500:2012 cl. 3.17 (procedure PRS-02) | MIL-STD 461F (procedure RS103) | MIL-STD 461G (procedure RS103) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.33 (procedure NRS02) | NO-A-STANAG-4370/AECTP-500-2:2021 cl. 3.14 (procedure NRS02.2)
26 Military equipment. Electrical, telecommunications and electronic products and equipment. Radiated radio-frequency electromagnetic field immunity test Measurement in a 3 m SAC chamber PN-EN 61000-4-3:2021-06 | PN-EN 55016-2-4:2005
27 Military equipment. Electrical, telecommunications and electronic products and equipment. Immunity to electrostatic discharge
Ranges up to ±15 kV (contact discharges) Ranges up to ±30 kV (air discharges)
PN-EN 61000-4-2:2011 | MIL-STD 461G (procedure CS118) | NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.27 (procedure NCS12) | NO-A-STANAG-4370/AECTP-500-2:2021 cl. 3.10 (procedure NCS12.2)
28 Electrical, telecommunications and electronic products and equipment. Surge immunity 1,2/50 µs, 8/20 µs for power supply ports PN-EN 61000-4-5:2014-10
29 Electrical, telecommunications and electronic products and equipment. Surge immunity 1,2/50 µs, 8/20 µs for signal and control ports PN-EN 61000-4-5:2014-10
30 Electrical, telecommunications and electronic products and equipment. Electrical fast transient/burst immunity, Power supply port
Range 5,5 kV
PN-EN 61000-4-4:2013-05
31 Electrical, telecommunications and electronic products and equipment. Electrical fast transient/burst immunity, Signal and control port
Range up to 2 kV
PN-EN 61000-4-4:2013-05
32 Electrical, telecommunications and electronic products and equipment. Immunity to voltage dips, short interruptions and voltage variations
Voltage dips 0 %, 40 %, 70 %, 80 % Voltage interruptions 0%
PN-EN 61000-4-11:2020-11
33 Military equipment. Electrical, telecommunication and electronic products and equipment Electrical insulation resistance
R from 50 kΩ to 200 GΩ Umeas (10 – 1000) VDC
NO-06-A108:2005, cl. 3.2 | NO-06-A108:2021, cl. 3.2
34 Military equipment. Electrical, telecommunication and electronic products and equipment Dielectric strength of the insulation
Up (0 - 5) kVAC Up (0 - 6) kVDC
NO-06-A108:2005, cl. 3.3 | NO-06-A108:2021, cl. 3.3
35 Electrical, telecommunications and electronic products and equipment Immunity to power-frequency magnetic field PN-EN 61000-4-8:2010
36 Electrical, telecommunications and electronic products and equipment Permissible levels of current harmonic emissions PN-EN IEC 61000-3-2:2019-04 | PN-EN 61000-3-12:2012 | PN-EN 61000-3-12:2012/A1:2024-11
37 Electrical, telecommunications and electronic products and equipment Voltage fluctuations and flicker in public low-voltage supply systems, caused by equipment with rated phase current 32 A PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN 61000-3-11:2020 -01
Environmental Testing Laboratory
38 Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm Strength, resistance, total resistance to low temperature
Minimum temperature -60 °C.
PN-EN 60068-2-1: 2009 | NO-06-A107:2005, cl. 4.3, 5.6 | NO-06-A107:2021, cl. 4.3, 5.6 | MIL-STD 810F, Method 502.4, procedures I and II | NO-A-STANAG-4370/AECTP-300-3:2022
39 Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm Strength, resistance, total resistance to high temperature
maximum temperature +170 °C minimum relative humidity 20 %.
PN-EN 60068-2-2:2009 | NO-06-A107:2005, cl. 4.2, 5.7 | NO-06-A107:2021, cl. 4.2, 5.7 | MIL-STD 810F, Method 501.4, procedures I and II | NO-A-STANAG-4370/AECTP-300-2:2022
40 Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm Strength, resistance, total resistance to damp heat, steady state/cyclic
relative humidity up to 95 % temp. from +20 °C to +85 °C
PN-EN 60068-2-30:2008 | PN-EN 60068-2-78:2013-11 | NO-06-A107:2005, cl. 4.4, Methods 1, 2 and Method 3, cl. 5.10 | NO-06-A107:2021, cl. 4.4, Methods 1, 2 and Method 3, cl. 5.10 | MIL-STD 810F, Method 507.4 | NO-A-STANAG-4370/AECTP-300-6:2022
41 Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm Strength and resistance to temperature changes
temp. min. -60 °C max. temp. +170 °C.
Method: single chamber. PN-EN IEC 60068-2-14:2024-04, test Nb | PN-EN 60068-2-14:2009, test Nb | NO-06-A107:2005, cl. 4.5, Method 2, cl. 5.9 | NO-06-A107:2021, cl. 4.5, Method 2, cl. 5.9
42 Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm Strength and resistance to temperature changes
temp. min. -60 °C max. temp. +170 °C.
Method: two chambers PN-EN IEC 60068-2-14:2024-04, test Na | PN-EN 60068-2-14:2009, test Na | NO-06-A107:2005, cl. 4.5, Method 1, cl. 5.8 | NO-06-A107:2021, cl. 4.5, Method 1, cl. 5.8 | MIL-STD 810F, Method 503.4, procedures I and II | NO-A-STANAG-4370/AECTP-300-4:2022
43 Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm Resistance to condensation atmospheric deposits (frost and dew) NO-06–A107:2005 + A1:2017, cl. 4.10. | NO-06–A107:2021, cl. 4.10.
44 Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Mechanical resonances of the structure.
frequency (5 – 40) Hz.
NO-06-A107:2005, cl. 2.2 | NO-06-A107:2021, cl. 2.2
45 Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Strength, resistance, total resistance to sinusoidal mechanical vibrations
Frequency (1 – 3000) Hz
PN-EN 60068-2-6:2008 | NO-06-A107:2005, cl. 2.3, 2.7, 2.12, 3.2 | NO-06-A107:2021, cl. 2.3, 2.7, 2.12, 3.2 | MIL-STD 810F, Method 514.5, procedure I
46 Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Strength, resistance, total resistance to mechanical shocks (half-sine / trapezoidal).
Peak acceleration amplitude respectively up to 1500 m/s² Surge duration (1 - 50) ms. Repetition frequency up to 3 Hz.
PN-EN 60068-2-27:2009 | NO-06-A107:2005, cl. 2.5, 2.9, 2.13, 3.4 | NO-06-A107:2021, cl. 2.5, 2.9, 2.13, 3.4
47 Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Strength, resistance, total resistance to broadband random vibrations
Frequency (10 – 2000) Hz Root mean square value GRMS up to 30 gn.
PN-EN 60068-2-64:2008 | NO-06-A107:2005, cl. 2.4, 2.8 | NO-06-A107:2021, cl. 2.4, 2.8 | MIL-STD- 810F, Method 514.5
48 Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Overall strength and resistance to transport NO-06-A107:2005, cl. 2.10 | NO-06-A107:2021, cl. 2.10
49 Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Resistance to free falls, drops and topples PN-EN 60068-2-31:2010 | NO-06-A107:2005, cl. 2.11 | NO-06-A107:2021, cl. 2.11 | MIL-STD 810F, Method 516.5, procedure IV
50 Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions: - horizontal cross-section Ǿ50 cm. Hermeticity. Resistance to immersion in water
Code IPX7 – IPX8
PN-EN 60529:2003, cl. 14.2.7 and 14.2.8 | NO-06-A107:2005, cl. 4.16, Method 2 | NO-06-A107:2021, cl. 4.16, Method 2 | MIL-STD 810F, Method 512.4, procedure I | NO-A-STANAG-4370/AECTP-300-7:2022
51 Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions up to: 50 cm x 50 cm x 50 cm Splash-proofness
Code IPX3 - IPX4
PN-EN 60529:2003, cl. 14.2.3 and cl. 14.2.4 | PN-EN 60529:2003/A2:2014-07
52 Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions up to: 50 cm x 50 cm x 50 cm Strength and resistance to rain (drip-proofness)
Code IPX1 – IPX2
PN-EN 60529:2003, cl. 14.2.1 and cl. 14.2.2 | PN-EN 60529:2003/A2:2014-07 | NO-06-A107:2005, cl. 4.18 | NO-06-A107:2021, cl. 4.18 | MIL-STD 810F, Method 506.4, procedure III
53 Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Dimensions: 67 cm x 67 cm x 20 cm Strength and resistance to dust (dust-tightness)
Code IP5X
PN-EN 60529:2003, cl. 13.4 and 13.5, category 2 | NO-06-A107:2005, cl. 4.12, Method 2, cl. 5.15 | NO-06-A107:2021, cl. 4.12, Method 2, cl. 5.15

Reference standards (144)

MIL-STD 461F (procedure CE102)
MIL-STD 461F (procedure CE106)
MIL-STD 461F (procedure CS101)
MIL-STD 461F (procedure CS114)
MIL-STD 461F (procedure CS115)
MIL-STD 461F (procedure CS116)
MIL-STD 461F (procedure RE102)
MIL-STD 461F (procedure RS101)
MIL-STD 461F (procedure RS103)
MIL-STD 461G (procedure CE102)
MIL-STD 461G (procedure CE106)
MIL-STD 461G (procedure CS101)
MIL-STD 461G (procedure CS114)
MIL-STD 461G (procedure CS115)
MIL-STD 461G (procedure CS116)
MIL-STD 461G (procedure CS118)
MIL-STD 461G (procedure RE102)
MIL-STD 461G (procedure RS101)
MIL-STD 461G (procedure RS103)
MIL-STD 810F, Method 501.4, procedures I and II
MIL-STD 810F, Method 502.4, procedures I and II
MIL-STD 810F, Method 503.4, procedures I and II
MIL-STD 810F, Method 506.4, procedure III
MIL-STD 810F, Method 507.4
MIL-STD 810F, Method 512.4, procedure I
MIL-STD 810F, Method 514.5, procedure I
MIL-STD 810F, Method 516.5, procedure IV
MIL-STD- 810F, Method 514.5
NO-06-A107:2005, cl. 2.10
NO-06-A107:2005, cl. 2.11
NO-06-A107:2005, cl. 2.2
NO-06-A107:2005, cl. 2.3, 2.7, 2.12, 3.2
NO-06-A107:2005, cl. 2.4, 2.8
NO-06-A107:2005, cl. 2.5, 2.9, 2.13, 3.4
NO-06-A107:2005, cl. 4.12, Method 2, cl. 5.15
NO-06-A107:2005, cl. 4.16, Method 2
NO-06-A107:2005, cl. 4.2, 5.7
NO-06-A107:2005, cl. 4.3, 5.6
NO-06-A107:2005, cl. 4.4, Methods 1, 2 and Method 3, cl. 5.10
NO-06-A107:2005, cl. 4.5, Method 1, cl. 5.8
NO-06-A107:2005, cl. 4.5, Method 2, cl. 5.9
NO-06-A107:2005, cl. 4.18
NO-06-A107:2021, cl. 2.10
NO-06-A107:2021, cl. 2.11
NO-06-A107:2021, cl. 2.2
NO-06-A107:2021, cl. 2.3, 2.7, 2.12, 3.2
NO-06-A107:2021, cl. 2.4, 2.8
NO-06-A107:2021, cl. 2.5, 2.9, 2.13, 3.4
NO-06-A107:2021, cl. 4.12, Method 2, cl. 5.15
NO-06-A107:2021, cl. 4.16, Method 2
NO-06-A107:2021, cl. 4.2, 5.7
NO-06-A107:2021, cl. 4.3, 5.6
NO-06-A107:2021, cl. 4.4, Methods 1, 2 and Method 3, cl. 5.10
NO-06-A107:2021, cl. 4.5, Method 1, cl. 5.8
NO-06-A107:2021, cl. 4.5, Method 2, cl. 5.9
NO-06-A107:2021, cl. 4.18
NO-06-A108:2005, cl. 3.2
NO-06-A108:2005, cl. 3.3
NO-06-A108:2021, cl. 3.2
NO-06-A108:2021, cl. 3.3
NO-06-A500:2012 (cl. 3.2 procedure PCE-02)
NO-06-A500:2012 (cl. 3.3 procedure PCE-03)
NO-06-A500:2012 cl. 3.10 (procedure PCS-07)
NO-06-A500:2012 cl. 3.11 (procedure PCS-08)
NO-06-A500:2012 cl. 3.16 (procedure PRS-01)
NO-06-A500:2012 cl. 3.17 (procedure PRS-02)
NO-06-A500:2012 cl. 3.4 (procedure PCS-01)
NO-06-A500:2012 cl. 3.9 (procedure PCS-06)
NO-06-A500:2012, cl. 3.14 (procedure PRE-02)
NO-06–A107:2005 + A1:2017, cl. 4.10.
NO-06–A107:2021, cl. 4.10.
NO-A-STANAG-4370/AECTP-300-2:2022
NO-A-STANAG-4370/AECTP-300-3:2022
NO-A-STANAG-4370/AECTP-300-4:2022
NO-A-STANAG-4370/AECTP-300-6:2022
NO-A-STANAG-4370/AECTP-300-7:2022
NO-A-STANAG-4370/AECTP-500- 1:2021 cl. 3.32 (procedure NRS01)
NO-A-STANAG-4370/AECTP-500- 2:2021 cl. 3.13 (procedure NRS01.2)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.12 (procedure NCE02)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.13 (procedure NCE03)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.16 (procedure NCS01)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.22 (procedure NCS07)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.23 (procedure NCS08)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.24 (procedure NCS09)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.27 (procedure NCS12)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.30 (procedure NRE02)
NO-A-STANAG-4370/AECTP-500-1:2021 cl. 3.33 (procedure NRS02)
NO-A-STANAG-4370/AECTP-500-2:2021 cl. 3.10 (procedure NCS12.2)
NO-A-STANAG-4370/AECTP-500-2:2021 cl. 3.12 (procedure NRE02.2)
NO-A-STANAG-4370/AECTP-500-2:2021 cl. 3.14 (procedure NRS02.2)
PN-EN 55016-2-1:2014-09
PN-EN 55016-2-3:2017-06
PN-EN 55016-2-3:2017-06/A1:2020-01
PN-EN 55016-2-3:2017-06/A2:2024-03
PN-EN 55016-2-4:2005
PN-EN 55022:2011, cl. 10
PN-EN 55022:2011, cl. 9
PN-EN 55032:2015-09
PN-EN 60068-2-14:2009, test Na
PN-EN 60068-2-14:2009, test Nb
PN-EN 60068-2-1: 2009
PN-EN 60068-2-27:2009
PN-EN 60068-2-2:2009
PN-EN 60068-2-30:2008
PN-EN 60068-2-31:2010
PN-EN 60068-2-64:2008
PN-EN 60068-2-6:2008
PN-EN 60068-2-78:2013-11
PN-EN 60529:2003, cl. 13.4 and 13.5, category 2
PN-EN 60529:2003, cl. 14.2.1 and cl. 14.2.2
PN-EN 60529:2003, cl. 14.2.3 and cl. 14.2.4
PN-EN 60529:2003, cl. 14.2.7 and 14.2.8
PN-EN 60529:2003/A2:2014-07
PN-EN 61000-3-11:2020 -01
PN-EN 61000-3-12:2012
PN-EN 61000-3-12:2012/A1:2024-11
PN-EN 61000-3-3:2013-10
PN-EN 61000-3-3:2013-10/A1:2019-10
PN-EN 61000-3-3:2013-10/A2:2022-04
PN-EN 61000-3-3:2013-10/AC:2022-05
PN-EN 61000-4-11:2020-11
PN-EN 61000-4-2:2011
PN-EN 61000-4-3:2021-06
PN-EN 61000-4-4:2013-05
PN-EN 61000-4-5:2014-10
PN-EN 61000-4-6:2014-04
PN-EN 61000-4-6:2024-03
PN-EN 61000-4-8:2010
PN-EN IEC 60068-2-14:2024-04, test Na
PN-EN IEC 60068-2-14:2024-04, test Nb
PN-EN IEC 61000-3-2:2019-04
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.1
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.2
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.4
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.5
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.6.2
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 7.7
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.1
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.3
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.4
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.5
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.6
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.7
PN-ETSI EN 300 086 V2.1.2:2017-02 cl. 8.8.2

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201132