🇵🇱 PRO-INFO s.c. PL

PCA AB 1121 • Bielsko-Biała, Poland • 46 methods

Environment

PRO-INFO s.c. is a laboratory accredited by PCA under number AB 1121 (Bielsko-Biała, Poland). Its accreditation scope covers 46 test methods in the following areas: Environment. Test objects include: Workplace environment − air, Workplace environment - electromagnetic field from equipment used i…, Workplace environment − electromagnetic field from industrial insta…, Workplace environment - electromagnetic field in the workspace duri…. Most frequently used techniques: Direct measurement method, Gravimetric method, Electrochemical method.

At a glance

  • Accreditation number: PCA AB 1121
  • Methods in scope: 46
  • Types of test objects: 16
  • Techniques used: 5
  • City: Bielsko-Biała, Poland
Accreditation number
AB 1121
Accreditation body
PCA
Address
Wojciech Kliś, Maciej Kliś, ZAKŁAD BADAŃ ŚRODOWISKA, ul. Wita Stwosza 11b, 43-300 Bielsko-Biała
City
Bielsko-Biała, Poland

What this laboratory tests (16)

Analytical techniques used (5)

Laboratory locations

Certificate information

Issue date
07.08.2026
Issue no.
24

Accreditation scope — test methods (46)

No. Test object Methodology / Parameters Technique Reference document
Environmental Testing Department
1 Workplace environment − air Air sampling for occupational exposure assessment to:
dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction metals and their compounds, including – inhalable fraction – respirable fraction asbestos respirable fibres man-made mineral fibres, excluding refractory ceramic fibres respirable fibres respirable ceramic fibres
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
2 Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
3 Workplace environment − air Air sampling for occupational exposure assessment to:
inorganic substances, including – inhalable fraction – thoracic fraction – respirable fraction
Stationary method; Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
4 Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
5 Workplace environment − air Concentration of harmful dust agents - inhalable fraction
Apatites and phosphorites Petroleum bitumen Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,07 – 17) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
6 Workplace environment − air Concentration of dust agents harmful to health- respirable fraction
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,07 - 17) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
7 Workplace environment − air Carbon monoxide concentration
Range (2,3 – 272 mg/m3 Range (2,0 – 235) ppm
Electrochemical method Test procedure PB-04 issue 11 of 26.05.2026
8 Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (22-137) dB C-weighted peak sound pressure level Range (30-140) dB
Direct measurement method PN-94/N-01307 | PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10
9 Workplace environment − noise Noise exposure level normalised to: (calculated)
an 8-hour daily working time average weekly working time
PN-94/N-01307 | PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10
10 Workplace environment − indoor electric lighting Illuminance
Range (5 – 9000) lx
Direct measurement method PN-83/E-04040.03 | Test procedure PB-03 issue 6 of 28.02.2025
11 Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03 | Test procedure PB-03 issue 6 of 28.02.2025
12 Workplace environment − emergency lighting Illuminance
Range (0,5 – 500) lx
Direct measurement method PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
13 Workplace environment − emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
14 Workplace environment − emergency lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
15 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (22-136) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) excluding cl. F
16 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) excluding cl. F
17 Workplace environment − hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,3 – 100) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
18 Workplace environment − hand-arm vibration Daily exposure, expressed as the 8-hour energy-equivalent vector sum of the effective frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz); Exposure lasting 30 minutes or less, expressed as the vector sum of the effective frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
19 Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,03 – 10) m/s2
Direct measurement method PN-EN 14253+A1:2011
20 Workplace environment − whole-body vibration Daily exposure, expressed as the 8-hour energy-equivalent effective frequency-weighted vibration acceleration, dominant among the vibration accelerations determined for the three directional components, taking into account the appropriate coefficients (1,4awx, 1,4awy, awz); Exposure lasting 30 minutes or less, expressed as the effective frequency-weighted vibration acceleration, dominant among the vibration accelerations determined for the three directional components, taking into account the appropriate coefficients (1,4awx, 1,4awy, awz) (calculated) PN-EN 14253+A1:2011
21 Workplace environment- energy expenditure Air temperature
Range (5,0 - 35,0) °C Air flow Range (10,1 – 60,4) dm3/min
Direct measurement method Test procedure PB-01 issue 5 of 28.02.2025
22 Workplace environment- energy expenditure Energy expenditure (calculated) Test procedure PB-01 issue 5 of 28.02.2025
23 Workplace environment – ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz
Range (54-143) dB
Direct measurement method PN-Z-01339-2020-12
24 Workplace environment – ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz normalized to: (calculated)
an 8-hour daily working time average weekly working time
PN-Z-01339-2020-12
25 Workplace environment – cold microclimate Air temperature
Range (-30 – 10) °C Black globe temperature Range (-30 – 10) °C Air humidity Range (20 – 90) % Air velocity Range (0,4 – 5,0) m/s
Direct measurement method PN-EN ISO 11079:2008
26 Workplace environment – cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008
27 Workplace environment – hot microclimate Air temperature
Range (10 – 50) °C Natural wet bulb temperature Range (10 – 50) °C Black globe temperature Range (10 – 50) °C
Direct measurement method PN-EN ISO 7243:2018-01
28 Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01
29 Workplace environment – moderate microclimate Air temperature
Range (10 – 30) °C Black globe temperature Range (10 – 40) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 1,0) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
30 Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
31 Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Electric field strength:
in the frequency range from 10 Hz up to 500 kHz Range 1 V/m – 50 kV/m in the frequency range from 0,2 MHz up to 30 MHz Range (1-288) V/m in the frequency range from 800 MHz up to 3 GHz Range (1-288) V/m
Regulated area: Method adapted to the regulated area
Direct measurement method PN-T-06580-3:2002 excluding cl. 2.1.4.2 | Working instruction No. IR-65 issue 1 of 12.06.2025
32 Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Magnetic flux density:
in the frequency range 0 Hz Range (0,1 – 1000) mT in the frequency range from 10 Hz up to 500 kHz Range 50 nT – 19 mT
Regulated area: Method adapted to the regulated area
Direct measurement method PN-T-06580-3:2002 excluding cl. 2.1.4.2 | Working instruction No. IR-65 issue 1 of 12.06.2025
33 Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Magnetic field strength:
in the frequency range from 0,2 MHz up to 30 MHz Range (0,01-16) A/m
Regulated area: Method adapted to the regulated area
Direct measurement method PN-T-06580-3:2002 excluding cl. 2.1.4.2 | Working instruction No. IR-65 issue 1 of 12.06.2025
34 Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Magnetic field strength: in the frequency range (calculated)
0 Hz from 10 Hz – 500 kHz from 800 MHz up to 3 GHz
Regulated area: Method adapted to the regulated area
PN-T-06580-3:2002 excluding cl. 2.1.4.2 | Working instruction No. IR-65 issue 1 of 12.06.2025
35 Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Electric field strength:
in the frequency range from 30 MHz up to 800 MHz Range (1-288) V/m
Direct measurement method PN-T-06580-3:2002 excluding cl. 2.1.4.2
36 Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Electric field strength:
in the frequency range from 10 Hz up to 500 kHz Range 1 V/m – 50 kV/m in the frequency range from 0,2 MHz up to 30 MHz Range (1-288) V/m in the frequency range from 800 MHz up to 3 GHz Range (1-288) V/m
Regulated area: Method adapted to the regulated area
Direct measurement method PN-T-06580-3:2002 excluding cl. 2.1.4.2 | Working instruction No. IR-66 issue 1 of 12.06.2025
37 Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Magnetic flux density:
in the frequency range 0 Hz Range (0,1 – 1000) mT in the frequency range from 10 Hz up to 500 kHz Range 50 nT – 19 mT
Regulated area: Method adapted to the regulated area
Direct measurement method PN-T-06580-3:2002 excluding cl. 2.1.4.2 | Working instruction No. IR-66 issue 1 of 12.06.2025
38 Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Magnetic field strength:
in the frequency range from 0,2 MHz up to 30 MHz Range (0,01-16) A/m
Regulated area: Method adapted to the regulated area
Direct measurement method PN-T-06580-3:2002 excluding cl. 2.1.4.2 | Working instruction No. IR-66 issue 1 of 12.06.2025
39 Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Magnetic field strength: in the frequency range (calculated)
0 Hz from 10 Hz – 500 kHz from 800 MHz up to 3 GHz
Regulated area: Method adapted to the regulated area
PN-T-06580-3:2002 excluding cl. 2.1.4.2 | Working instruction No. IR-66 issue 1 of 12.06.2025
40 Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Electric field strength:
in the frequency range from 30 MHz up to 800 MHz Range (1-288) V/m
Direct measurement method PN-T-06580-3:2002 excluding cl. 2.1.4.2
41 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Electric field strength:
in the frequency range from 10 Hz up to 500 kHz Range (1 – 50000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
42 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic flux density:
in the frequency range from 10 Hz up to 500 kHz Range 50 nT – 19 mT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
43 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic field strength: (calculated)
in the frequency range from 10 Hz up to 500 kHz
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331)
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
44 Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices Electric field strength:
in the frequency range from 10 Hz up to 1 kHz Range (1 – 50000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
45 Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices Magnetic flux density:
in the frequency range from 10 Hz up to 1 kHz Range 50 nT – 19 mT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
46 Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices Magnetic field strength: (calculated)
in the frequency range from 10 Hz up to 1 kHz
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331)
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180

Reference standards (27)

Working instruction No. IR-65 issue 1 of 12.06.2025
Working instruction No. IR-66 issue 1 of 12.06.2025
PN-83/E-04040.03
PN-94/N-01307
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10
PN-T-06580-3:2002 excluding cl. 2.1.4.2
PN-Z-01339-2020-12
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Test procedure PB-01 issue 5 of 28.02.2025
Test procedure PB-03 issue 6 of 28.02.2025
Test procedure PB-04 issue 11 of 26.05.2026
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) excluding cl. F

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201121