🇵🇱 EWA NICGÓRSKA-DZIERKO „EQM” SYSTEM I ŚRODOWISKO PL

PCA AB 1115 • Wieliczka, Poland • 16 methods

EnvironmentMetrology & calibration

EWA NICGÓRSKA-DZIERKO „EQM” SYSTEM I ŚRODOWISKO is a laboratory accredited by PCA under number AB 1115 (Wieliczka, Poland). Its accreditation scope covers 16 test methods in the following areas: Environment, Metrology & calibration. Test objects include: Rooms in residential, collective residence and public utility build…, General environment – noise from installations, equipment and indus…, General environment – noise from roads, railway lines, tram lines, General environment – impulse noise from installations and equipment.

At a glance

  • Accreditation number: PCA AB 1115
  • Methods in scope: 16
  • Types of test objects: 6
  • City: Wieliczka, Poland
Accreditation number
AB 1115
Accreditation body
PCA
Address
ul. Tadeusza Kościuszki 36G lok. 16, 32-020 Wieliczka
City
Wieliczka, Poland

What this laboratory tests (6)

Certificate information

Issue date
05.12.2025
Issue no.
19

Accreditation scope — test methods (16)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (24 – 137) dB Direct measurement method No. 7 | …regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706); PN ISO 9613-2:2002
2 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
3 General environment – noise from installations, equipment and industrial plants Calculation method
4 General environment – impulse noise from installations and equipment A-weighted equivalent sound level Range: (24 – 137) dB Direct measurement method No. 8 | …regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706)
5 General environment – impulse noise from installations and equipment A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
6 General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Range: (24 – 137) dB Direct measurement method No. 3 | …regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws No. 140 | No. 288 | ISO 9613-2:2002 NMPB-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads 2011
7 General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
8 General environment – noise from roads, railway lines, tram lines Calculation method
9 Machinery and equipment – noise Sound pressure level in 1/3 octave bands Mid-band frequency range: (125 – 8 000) Hz Sound pressure level A-weighted sound pressure level A-weighted single event sound pressure level Range: (24 – 137) dB Direct measurement method PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09
10 Machinery and equipment – noise Sound power level Sound energy level (calculated)
11 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level A-weighted maximum sound level Range: (22 – 119) dB Direct measurement method PN-87/B-02156
12 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated)
13 Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms A-weighted equivalent sound level A-weighted maximum sound level Range: (22 – 119) dB Direct measurement method PN-EN ISO 10052:2007 PN-EN ISO 10052:2007/A1:2010
14 Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms Reference A-weighted equivalent sound level for the work cycle Reference A-weighted maximum sound level for the work cycle (calculated)
15 Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms A-weighted and C-weighted equivalent sound level A-weighted and C-weighted maximum sound level Range (22 – 119) dB Sound pressure level in 1/1 octave bands with centre frequency range: 31,5 – 8 000 Hz Direct measurement method PN-EN ISO 16032:2006
16 Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms Reverberation time in octave and 1/3-octave bands Engineering method PN-EN ISO 3382-2:2010

Reference standards (13)

ISO 9613-2:2002 NMPB-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads 2011
PN-87/B-02156
PN-EN ISO 10052:2007 PN-EN ISO 10052:2007/A1:2010
PN-EN ISO 16032:2006
PN-EN ISO 3382-2:2010
PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09
…regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706)
…regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706); PN ISO 9613-2:2002
…regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws No. 140
No. 288
No. 3
No. 7
No. 8

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201115