🇵🇱 Laboratorium SMC Sp. z o.o. PL

PCA AB 1100 • Michałowice, Poland • 62 methods

Environment

Laboratorium SMC Sp. z o.o. is a laboratory accredited by PCA under number AB 1100 (Michałowice, Poland). Its accreditation scope covers 62 test methods in the following areas: Environment. Test objects include: Workplace environment - non-laser optical radiation, Workplace environment - air, Workplace environment – emergency lighting, Workplace environment − electromagnetic field. Most frequently used techniques: Direct measurement method, Direct measurement method; Sampling method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 1100
  • Methods in scope: 62
  • Types of test objects: 21
  • Techniques used: 12
  • City: Michałowice, Poland
Accreditation number
AB 1100
Accreditation body
PCA
Address
ul. Malownicza 16, 32-091 Michałowice, Laboratorium Badań Środowiskowych, ul. Leśna 85
City
Michałowice, Poland

What this laboratory tests (21)

Analytical techniques used (12)

Laboratory locations

Certificate information

Issue date
16.07.2026
Issue no.
23

Accreditation scope — test methods (62)

No. Test object Methodology / Parameters Technique Reference document
Environmental Testing Laboratory
1 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (25 - 135) dB C-weighted peak sound pressure level Range (35 - 138) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding cl. 10 (strategy 2)
2 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding cl. 10 (strategy 2)
3 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 - 137) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F
4 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F
5 Machinery and equipment – noise A-weighted equivalent sound pressure level
Range (25 - 137) dB
Direct measurement method PN-EN ISO 3746:2011 excluding cl. 8.4. | PN-EN ISO 3746:2011/Ap1:2017-09
6 Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3746:2011 excluding cl. 8.4. | PN-EN ISO 3746:2011/Ap1:2017-09
7 Workplace environment - air Sampling for the assessment of exposure to:
dust agents inhalable fraction respirable fraction
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
8 Workplace environment - air Sampling for the assessment of exposure to:
metals and their compounds, including inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction respirable fibres
Personal dosimetry method; Stationary method PN-Z-04008-7:2002+Az1:2004
9 Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
10 Workplace environment - air Concentration of harmful dust agents – inhalable fraction:
Apatites and phosphorites Portland cement Titanium dioxide Graphite: a) natural graphite b) synthetic graphite Kaolin Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Talc Calcium sulfate (VI) (gypsum) Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,14 - 17,0) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
11 Workplace environment - air Concentration of harmful dust agents – respirable fraction:
Apatites and phosphorites Portland cement Graphite a) natural graphite Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,10 - 7,9) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
12 Workplace environment - air Carbon monoxide concentration
CO (2,32 - 174) mg/m3 Range (2 - 150) ppm
Electrochemical method PB-01 issue 9 of 27.05.2026
13 Workplace environment - air Exposure index (calculated) PB-01 issue 9 of 27.05.2026
14 Workplace environment - indoor electric lighting Illuminance
Range (5 - 10 000) lx
Direct measurement method PN-83/E-04040-03
15 Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040-03
16 Workplace environment - outdoor electric lighting Illuminance
Range (5 - 10 000) lx
Direct measurement method PN-83/E-04040-03
17 Workplace environment - outdoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040-03
18 Workplace environment – emergency lighting Illuminance
Range (0,5 - 200) lx
Direct measurement method PN-EN 1838:2025-05 excluding cl. 5.1.3 - 5.1.5; 5.2.3 - 5.2.5; 5.3.4 - 5.3.7; 6
19 Workplace environment – emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2025-05 excluding cl. 5.1.3 - 5.1.5; 5.2.3 - 5.2.5; 5.3.4 - 5.3.7; 6
20 Workplace environment – emergency lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2025-05 excluding cl. 5.1.3 - 5.1.5; 5.2.3 - 5.2.5; 5.3.4 - 5.3.7; 6
21 Workplace environment – moderate microclimate Air temperature
Range (10 - 30) °C Black globe temperature Range (10 - 50) °C Air humidity Range (20 - 90) % Air velocity Range (0,15 - 1,5) m/s
Direct measurement method PN-EN ISO 7730:2006
22 Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006
23 Workplace environment – hot microclimate Air temperature
Range (10 - 40) °C Natural wet bulb temperature Range (10 - 40) °C Black globe temperature Range (10 - 50) °C
Direct measurement method PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04
24 Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04
25 Workplace environment − cold microclimate Air temperature
Range (-10) °C - 10 °C Black globe temperature Range (-10) °C - 10°C Air humidity Range (20 - 90) % Air velocity Range (0,15 - 1,5) m/s
Direct measurement method PN-EN ISO 11079:2008
26 Workplace environment − cold microclimate twc index, IREQ min and IREQneutral index (calculated) PN-EN ISO 11079:2008
27 Workplace environment – energy expenditure Air flow
Range (10 - 60 ) dm3/min
Direct measurement method PB-02 issue 5 of 01.06.2026
28 Workplace environment – energy expenditure Energy expenditure (calculated) PB-02 issue 5 of 01.06.2026
29 Workplace environment − whole-body vibration RMS frequency-weighted vibration acceleration.
Range (0,006 - 25) m/s2
Direct measurement method; Sampling method PN-EN 14253+A1:2011
30 Workplace environment − whole-body vibration Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes and less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
31 Workplace environment − local vibration acting on the human body Frequency-weighted r.m.s. vibration acceleration
Range (0,06 - 100) m/s2
Direct measurement method; Sampling method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015
32 Workplace environment − local vibration acting on the human body Daily exposure, expressed as the energy-equivalent for 8 hours of the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes and less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015
33 Environment – rooms intended for work and human occupancy Air flow measurement
- at terminal devices Range (0,3 - 20) m/s - in the cross-section of the ventilation duct Range (0,3 - 20) m/s Air volume flow Air change rate
Vane anemometer measurement method; Thermoanemometer measurement method PN-EN 12599:2013-04
34 Workplace environment - non-laser optical radiation Effective irradiance UVA, UVB, UVC in the spectral range (180 - 400) nm
Range (10-6 - 39.99) W/m2
Method A PN-EN 14255-1:2010
35 Workplace environment - non-laser optical radiation Effective radiant exposure for UV in the spectral range (180 - 400) nm (calculated) PN-EN 14255-1:2010
36 Workplace environment - non-laser optical radiation Irradiance for UVA in the spectral range (315 - 400) nm
Range (10-3 - 3990) W/m2
Direct measurement method (method M) PN-EN 14255-1:2010
37 Workplace environment - non-laser optical radiation Radiant exposure for UVA in the spectral range (315 - 400) nm (calculated) PN-EN 14255-1:2010
38 Workplace environment - non-laser optical radiation Effective irradiance for VIS in the spectral range (300 - 700) nm
Range (10-6 - 399) W/m2
Direct measurement method (method O) PN-EN 14255-2:2010 | PN-T-05687:2002 cl. 2.5.5
39 Workplace environment - non-laser optical radiation Effective radiance for VIS in the spectral range (300 - 700) nm (calculated) PN-EN 14255-2:2010 | PN-T-05687:2002 cl. 2.5.5
40 Workplace environment - non-laser optical radiation Irradiance of VIS, IRA, IRB in the spectral range (380 - 3000) nm
Range (30 - 3999) W/m2
Direct measurement method (method X) PN-EN 14255-2:2010 | PN-T-05687:2002 cl. 2.5.5
41 Workplace environment - non-laser optical radiation Radiant exposure for VIS, IRA, IRB in the spectral range (380 - 3000) nm (calculated) PN-EN 14255-2:2010 | PN-T-05687:2002 cl. 2.5.5
42 Workplace environment - non-laser optical radiation Effective irradiance for VIS, IRA in the spectral range (380 - 1400) nm
Range (10-6 - 39900) W/m2
Direct measurement method PN-T-05687:2002 cl. 2.5.5
43 Workplace environment - non-laser optical radiation Effective radiance for VIS, IRA in the spectral range (380 - 1400) nm (calculated) PN-T-05687:2002 cl. 2.5.5
44 Workplace environment - non-laser optical radiation Effective irradiance for IRA in the spectral range (780 - 1400) nm
Range (10-3 - 3990) W/m2
Direct measurement method PN-T-05687:2002 cl. 2.5.4 and 2.5.5 | PB-09 issue 1 of 06.07.2023
45 Workplace environment - non-laser optical radiation Effective radiance for IRA in the spectral range (780 - 1400) nm (calculated) PN-T-05687:2002 cl. 2.5.4 and 2.5.5 | PB-09 issue 1 of 06.07.2023
46 Workplace environment - non-laser optical radiation Effective irradiance for IRB in the spectral range (1400 - 3000) nm
Range (30 - 3999) W/m2
Direct measurement method PN-T-05687:2002 cl. 2.5.4 and 2.5.5 | PB-09 issue 1 of 06.07.2023
47 Workplace environment - non-laser optical radiation Effective radiance for IRB in the spectral range (1400 - 3000) nm (calculated) PN-T-05687:2002 cl. 2.5.4 and 2.5.5 | PB-09 issue 1 of 06.07.2023
48 Workplace environment - non-laser optical radiation Irradiance for IRA and IRB in the spectral range (780 - 3000) nm
Range (30 - 3999) W/m2
Direct measurement method (method R) PN-EN 14255-2:2010 | PN-T-05687:2002 cl. 2.5.4
49 Workplace environment - non-laser optical radiation Irradiance for the eye in the spectral range (780 - 3000) nm
Range (30 - 3999) W/m2 (calculated)
PN-EN 14255-2:2010 | PN-T-05687:2002 cl. 2.5.4
50 Rooms in residential, collective residence and public utility buildings - noise A-weighted equivalent sound level A-weighted maximum sound level
Range (24 - 110) dB
Direct measurement method PN-87/B-02156
51 Rooms in residential, collective residence and public utility buildings - noise A-weighted equivalent sound level for reference time T (calculated) PN-87/B-02156
52 Rooms in residential, collective residence and public buildings - noise from building service equipment penetrating into rooms A-weighted equivalent sound level A-weighted maximum sound level
Range (24 - 110) dB
Direct measurement method PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12
53 Rooms in residential, collective residence and public buildings - noise from building service equipment penetrating into rooms Reference A-weighted equivalent sound level for the work cycle, Reference A-weighted maximum sound level for the work cycle (calculated) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12
54 Workplace environment − electromagnetic field Electric field strength in the frequency range from 10 Hz to 40 MHz
Range (2 - 40 000) V/m
Direct measurement method PN-T-06580-3:2002 excluding cl. 2.1.4.2 Method adapted to the regulated area.
55 Workplace environment − electromagnetic field Magnetic flux density in the frequency range from 10 Hz to 30 MHz
Range (0,02 μT - 20 000 μT) Magnetic field strength in the frequency range from 10 Hz up to 30 MHz (calculated)
Direct measurement method PN-T-06580-3:2002 excluding cl. 2.1.4.2 Method adapted to the regulated area.
56 Workplace environment − electromagnetic field Magnetic flux density 0 Hz
Range (0,1 mT - 1 200 mT) Magnetic field strength in the frequency range 0 Hz (calculated)
Direct measurement method PN-T-06580-3:2002 excluding cl. 2.1.4.2 Method adapted to the regulated area.
57 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Electric field strength in the frequency range from 10 Hz to 1 kHz
Range (2 - 40 000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
58 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density in the frequency range from 10 Hz to 1 kHz
Range (0,4 - 20 000) μT Magnetic field strength in the frequency range from 10 Hz up to 1 kHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
59 Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Electric field strength in the 50 Hz frequency band
Range (100 - 40 000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
60 Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Magnetic flux density in the frequency range 50 Hz
Range (1 - 20 000) μT Magnetic field strength in the frequency range 50 Hz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
61 Environment − electromagnetic field in the vicinity of power substations and lines Electric field strength in the 50Hz frequency range
Range (100 - 20 000) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended)
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
62 Environment − electromagnetic field in the vicinity of power substations and lines Magnetic flux density in the frequency range 50 Hz
Range (1 - 20 000) μT Magnetic field strength in the frequency range 50 Hz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended)
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)

Reference standards (38)

PB-01 issue 9 of 27.05.2026
PB-02 issue 5 of 01.06.2026
PB-09 issue 1 of 06.07.2023
PN-83/E-04040-03
PN-87/B-02156
PN-EN 12599:2013-04
PN-EN 14253+A1:2011
PN-EN 14255-1:2010
PN-EN 14255-2:2010
PN-EN 1838:2025-05 excluding cl. 5.1.3 - 5.1.5; 5.2.3 - 5.2.5; 5.3.4 - 5.3.7; 6
PN-EN ISO 10052:2007
PN-EN ISO 10052:2007/A1:2010
PN-EN ISO 10052:2021-12
PN-EN ISO 11079:2008
PN-EN ISO 3746:2011 excluding cl. 8.4.
PN-EN ISO 3746:2011/Ap1:2017-09
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004+A1:2015
PN-EN ISO 7243:2018-01
PN-EN ISO 7243:2018-01/Ap2:2020-04
PN-EN ISO 7730:2006
PN-EN ISO 9612:2025-11 excluding cl. 10 (strategy 2)
PN-N-01307:1994
PN-T-05687:2002 cl. 2.5.5
PN-T-05687:2002 cl. 2.5.4
PN-T-05687:2002 cl. 2.5.4 and 2.5.5
PN-T-05687:2002 cl. 2.5.5
PN-T-06580-3:2002 excluding cl. 2.1.4.2 Method adapted to the regulated area.
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201100