🇵🇱 WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ – PL

PCA AB 1087 • Nowy Dwór Mazowiecki, Poland • 69 methods

EnvironmentWater & wastewaterMicrobiologyFood & beverages

WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ – is a laboratory accredited by PCA under number AB 1087 (Nowy Dwór Mazowiecki, Poland). Its accreditation scope covers 69 test methods in the following areas: Environment, Water & wastewater, Microbiology, Food & beverages. Test objects include: Water intended for human consumption, Meat and meat products, Milk and dairy products, Water intended for human consumption, Swimming pool water, Workplace environment - air. Most frequently used techniques: Direct measurement method, Membrane filtration method, Plate method (pour plate).

At a glance

  • Accreditation number: PCA AB 1087
  • Methods in scope: 69
  • Types of test objects: 25
  • Techniques used: 24
  • City: Nowy Dwór Mazowiecki, Poland
Accreditation number
AB 1087
Accreditation body
PCA
Address
MODLIN IM. PŁK LEK. MIKOŁAJA ZYGMUNTA, KWAŚNIEWSKIEGO, ZESPÓŁ LABORATORYJNY, ul. Leśna 4D
City
Nowy Dwór Mazowiecki, Poland

What this laboratory tests (25)

Analytical techniques used (24)

Laboratory sections (4)

Laboratory locations

Certificate information

Issue date
31.07.2026
Issue no.
19

Accreditation scope — test methods (69)

No. Test object Methodology / Parameters Technique Reference document
Laboratory Team; Food and Water Testing Laboratory
1 Meat and meat products, Milk and dairy products Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 + A1:2020-09
2 Meat and meat products, Milk and dairy products Presence of coagulase-positive staphylococci (Staphylococcus aureus and other species) Tube culture method with biochemical confirmation PN-EN ISO 6888-3:2004+AC:2005
3 Meat and meat products, Milk and dairy products Coagulase-positive staphylococci count (Staphylococcus aureus and other species) Plate method (pour plate) PN-EN ISO 6888-2:2022-03 + A1:2024-02
4 Meat and meat products, Milk and dairy products Presence of Listeria monocytogenes Culture method with biochemical confirmation PN-EN ISO 11290-1:2017-07
5 Meat and meat products, Milk and dairy products Listeria monocytogenes count Plate method (spread plate) PN-EN ISO 11290-2:2017-07
6 Meat products, canned meat and vegetable-meat products, Milk and dairy products, Fish products, canned fish Count of β-glucuronidase-positive Escherichia coli Plate method (pour plate) PN-ISO 16649-2:2004
7 Meat products, canned meat and vegetable-meat products, Milk and dairy products, Fish products, canned fish Coliform bacteria count Plate method (pour plate) PN-ISO 4832:2007
8 Meat products, canned meat and vegetable-meat products, Milk and dairy products, Fish products, canned fish Total aerobic viable count Plate method (pour plate) PN-EN ISO 4833-1: 2013-12+Ap1:2016-11+A1:2022-06
9 Canned products – meat and meat products Shelf stability of canned products Thermostatic method PN-A-82055-5: 1994
10 Canned products – meat and meat products Tightness of canned products Vacuum method PN-A-82055-4: 1997 cl. 2.4.1.2 + Az1:2002
11 Canned vegetable – meat, vegetable and fruit products Tightness of canned products Vacuum method PN -90/A-75052/02 cl. 2.2.2
12 Canned vegetable – meat, vegetable and fruit products Shelf stability of canned products Thermostatic method PN-90/A-75052/03
13 Canned fish Tightness of canned products Vacuum method PN-92/A-86732 cl. 2.3.10
14 Canned fish Shelf stability of canned products Thermostatic method PN-92/A-86732 cl. 2.3.11
15 Water intended for human consumption Total count of microorganisms at 22ºC Plate method (pour plate) PN-EN ISO 6222:2004
16 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
17 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
18 Water intended for human consumption, Swimming pool water Total count of microorganisms at 36ºC Plate method (pour plate) PN-EN ISO 6222:2004
19 Water intended for human consumption, Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
20 Water intended for human consumption, Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
21 Water intended for human consumption, Swimming pool water Number of Legionella bacteria, Matrix B, Procedure 7 (medium C-GVPC) Membrane filtration method PN-EN ISO 11731:2017-08 +AP1:2019-12
22 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PB-01-PM issue II of 06.06.2019 developed on the basis of the NIZP-PZH methodology ZHK:2007
23 Water intended for human consumption Colour
Range (2 – 70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015-06 Method C
24 Water intended for human consumption Turbidity
Range (0,10 – 10) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
25 Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
26 Water intended for human consumption Electrical conductivity
Range (84 – 2500) μS/cm
Conductometric method PN-EN 27888:1999
27 Water intended for human consumption Chloride concentration
Range (5 – 300) mg/l
Titrimetric method PN-ISO 9297:1994
28 Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (5 – 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
29 Water intended for human consumption Nitrite concentration
Range (0,010 -0,6) mg/l
Spectrophotometric method PN-EN 26777:1999
30 Water intended for human consumption Iron concentration
Range (30-3000) µg/l
Spectrophotometric method HACH LANGE method No. 8008 issue I of 09.2005
31 Water intended for human consumption Manganese concentration
Range (9 – 700) µg/l
Spectrophotometric method HACH LANGE method No. 8149 issue I of 04.2005
32 Water intended for human consumption Metal concentrations
Chromium (10 – 100) µg/l Manganese (10 – 500) µg/l Iron (20 – 700) µg/l Copper (0,030 – 2,0) mg/l Aluminium (30 – 500) µg/l Cadmium (1,0 – 10) µg/l Nickel (5 – 40) µg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
Laboratory Team; Working Environment Testing Laboratory
33 Workplace environment - electromagnetic field in the workspace originating from radar equipment Electric field strength:
in the frequency range from 800 MHz to 18 GHz Range (5 - 600) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
Direct measurement method NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
34 Workplace environment - electromagnetic field in the workspace originating from radar equipment Magnetic field strength:
in the frequency range from 800 MHz to 18 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
35 Workplace environment - electromagnetic field in the workspace originating from missile guidance stations Electric field strength:
in the frequency range from 800 MHz to 18 GHz Range (5 - 600) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
Direct measurement method NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
36 Workplace environment - electromagnetic field in the workspace originating from missile guidance stations Magnetic field strength:
in the frequency range from 800 MHz to 18 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
37 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Electric field strength:
in the frequency range from 0,1 MHz to 18 GHz Range (1 - 1000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
Direct measurement method NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
38 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength:
in the frequency range from 0,1 MHz to 800 MHz Range (0,01 – 15) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
Direct measurement method NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
39 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength:
in the frequency range from 800 MHz to 18 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
40 Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Electric field strength:
in the frequency range from 0,1 MHz to 18 GHz Range (1 - 1000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
Direct measurement method NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
41 Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Magnetic field strength:
in the frequency range from 0,1 MHz to 800 MHz Range (0,01 – 15) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
Direct measurement method NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
42 Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Magnetic field strength:
in the frequency range from 800 MHz to 18 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
43 Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Electric field strength:
in the frequency range from 0,1 MHz to 18 GHz Range (1 - 1000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
Direct measurement method NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
44 Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Magnetic field strength:
in the frequency range from 0,1 MHz to 800 MHz Range (0,01 – 15) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
Direct measurement method NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
45 Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Magnetic field strength:
in the frequency range from 800 MHz to 18 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
46 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Electric field strength:
in the frequency range from 0,1 MHz to 800 MHz Range (1 - 1000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
Direct measurement method NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
47 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Magnetic field strength:
in the frequency range from 0,1 MHz to 1 GHz Range (0,01 – 15) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
Direct measurement method NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
48 Workplace environment - electromagnetic field in the work space originating from control and measurement stations Electric field strength:
in the frequency range from 0,1 MHz to 18 GHz Range (1 - 1000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
Direct measurement method NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
49 Workplace environment - electromagnetic field in the work space originating from control and measurement stations Magnetic field strength:
in the frequency range from 0,1 MHz to 800 MHz Range (0,01 – 15) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
Direct measurement method NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
50 Workplace environment - electromagnetic field in the work space originating from control and measurement stations Magnetic field strength:
in the frequency range from 800 MHz to 18 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of Decision No. 171/MON of the Minister of National Defence of 27.10.2017 (Official Journal of the Ministry of National Defence of 2017, item 208, as amended).
NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
51 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic field strength:
in the frequency range from 20 Hz to 50 Hz Range (0,01 – 50) mT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method (simplified) Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
52 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (44 – 157) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 - cl. 10 and 11
53 Workplace environment - noise C-weighted peak sound pressure level
Range (44 – 157) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 - cl. 10 and 11
54 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 - cl. 10 and 11
55 Workplace environment - air Sampling for the assessment of occupational exposure to:
dust agents inhalable fraction respirable fraction inorganic substances respirable fraction metals and their compounds, including inhalable fraction respirable fraction organic substances
Personal dosimetry method PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Ap1:2004
56 Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Ap1:2004
57 Workplace environment - air Concentration of harmful dust agents – inhalable fraction
wood dusts coal (hard, brown) dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts Range (0,04 – 30,66) mg/m3
Gravimetric method PN-Z-04507:2022-05
58 Workplace environment - air Concentration of harmful dust agents – respirable fraction
coal (hard, brown) organic dusts of animal and plant origin, excluding wood and flour dusts Range (0,04 – 12,39) mg/m3
Gravimetric method PN-Z-04508:2022-05
59 Workplace environment - air - air samples collected on filters Concentration of iron oxides calculated as Fe
Iron(III) oxide Iron(II) oxide Triiron tetraoxide inhalable fraction (0,417 – 20,833) mg/m3 respirable fraction (0,189 – 9,470) mg/m3
Flame atomic absorption spectrometry (FAAS) PN-Z-04469:2015-10
60 Workplace environment - air - air samples collected on filters Concentration of manganese and its inorganic compounds calculated as Mn
inhalable fraction (0,017 – 0,444) mg/m3 respirable fraction (0,004 – 0,101) mg/m3
Flame atomic absorption spectrometry (FAAS) PN-Z-04472:2015-10 | PN-Z-04472:2015-10/AP1:2015-12
61 Workplace environment - air - air samples collected on filters Concentration of lead and its inorganic compounds, except lead(II) arsenate(V) and lead(II) chromate(VI) – expressed as Pb
inhalable fraction (0,0035 – 0,1389) mg/m3
Flame atomic absorption spectrometry (FAAS) PN-Z-04487:2017-10
62 Workplace environment - air - air samples collected on filters Crystalline silica (quartz, cristobalite) concentration/content
respirable fraction (0,013 – 0,505) mg/m3 respirable fraction (10 – 400) μg in the sample
Fourier transform infrared spectrometry (FT-IR) Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
63 Workplace environment - air - air samples collected into sorbent tubes Concentration / content of organic compounds
acetone (38,3 – 3833) mg/m3 acetone (0,03 – 3,45) mg in the sample butan-1-ol (4,5 – 450) mg/m3 butan-1-ol (0,03 – 3,24) mg in the sample 2-butoxyethanol (8,5 – 425) mg/m3 2-butoxyethanol (0,06 – 3,06) mg in the sample ethanol (84,2 – 4208) mg/m3 ethanol (0,02 – 0,95) mg in the sample 2-ethoxyethanol (0,5 – 26) mg/m3 2-ethoxyethanol (0,002 – 0,09) mg in the sample xylene (mixture of isomers 1,2; 1,3; 1,4) (4,3 – 433) mg/m3 xylene (mixture of isomers 1,2; 1,3; 1,4) (0,03 – 3,12) mg in the sample 2-Methylpropan-1-ol (4,9 – 490) mg/m3 2-Methylpropan-1-ol (0,04 – 3,53) mg in the sample n-butyl acetate (19,6 – 1960) mg/m3 n-butyl acetate (0,14 – 14,11) mg in the sample 2-ethoxyethyl acetate (1,0 – 49) mg/m3 2-ethoxyethyl acetate (0,01 – 0,35) mg in the sample ethyl acetate (20,0 – 3007) mg/m3 ethyl acetate (0,14 – 21,65) mg in the sample toluene (8,2 – 409) mg/m3 toluene (0,06 – 2,95) mg in the sample
Gas chromatography with mass spectrometry detection (GC-MS) PN-Z-04023-02:1989
64 Workplace environment - air - air samples collected into sorbent tubes Concentration / content of organic compounds
benzene (0,05 – 3,54) mg/m3 benzene (0,001 – 0,070) mg in the sample
Gas chromatography with mass spectrometry detection (GC-MS) PN-Z-04016:2005-10
Laboratory Team; Microbiological Laboratory
65 Faeces / faecal swab Presence of Salmonella and Shigella rods Culture method with biochemical and serological confirmation PB-01-LM, issue 5 of 10.05.2026, based on the publication by M. Jagielski, Aetiology, clinical picture and diagnosis of acute gastrointestinal infections and infestations and of food poisoning, edition I, 2010; White–Kauffmann–Le Minor scheme, 9th edition of 2007
66 Biological indicator for monitoring sterilisation effectiveness Sporal A Presence of the indicator microorganisms Geobacillus stearothermophilus Culture method PB-02-LM, issue 6 of 01.02.2026 based on the test manufacturer's instructions
67 Faeces / Rectal swab Presence of Salmonella and Shigella rods Culture method with biochemical and serological confirmation PB-04-LM, issue 3 of 10.05.2026, based on the publication by M. Jagielski, Aetiology, clinical picture and diagnosis of acute gastrointestinal infections and infestations and of food poisoning, edition I, 2010; White–Kauffmann–Le Minor scheme, 9th edition of 2007
68 Faecal swab, rectal swab / faeces Detection of nucleic acids specific to Salmonella sp., Shigella sp./enteroinvasive E. coli strains (EIEC), Yersinia enterocolitica, Campylobacter (jejuni, coli and upsaliensis) Nested multiplex PCR method FilmArray®Gastrointestrial (GI) Panel test manufacturer's instructions of 04.06.2017
Laboratory Team; Radiation Hygiene Laboratory
69 Dosimeters in an ionising radiation field Personal dose equivalent Hp(10) of photon radiation
Range (0,05 – 1500) mSv
Thermoluminescence dosimetry method (TLD) PB-03-LHR of 01.02.2022

Reference standards (50)

FilmArray®Gastrointestrial (GI) Panel test manufacturer's instructions of 04.06.2017
HACH LANGE method No. 8008 issue I of 09.2005
HACH LANGE method No. 8149 issue I of 04.2005
NO-06-A215-2:2022 Occupational Safety and Health. Protection against electromagnetic radiation. Part 2: Test methods
PB-01-LM, issue 5 of 10.05.2026, based on the publication by M. Jagielski, Aetiology, clinical picture and diagnosis of acute gastrointestinal infections and infestations and of food poisoning, edition I, 2010; White–Kauffmann–Le Minor scheme, 9th edition of 2007
PB-01-PM issue II of 06.06.2019 developed on the basis of the NIZP-PZH methodology ZHK:2007
PB-02-LM, issue 6 of 01.02.2026 based on the test manufacturer's instructions
PB-03-LHR of 01.02.2022
PB-04-LM, issue 3 of 10.05.2026, based on the publication by M. Jagielski, Aetiology, clinical picture and diagnosis of acute gastrointestinal infections and infestations and of food poisoning, edition I, 2010; White–Kauffmann–Le Minor scheme, 9th edition of 2007
PN -90/A-75052/02 cl. 2.2.2
PN-90/A-75052/03
PN-92/A-86732 cl. 2.3.10
PN-92/A-86732 cl. 2.3.11
PN-A-82055-4: 1997 cl. 2.4.1.2 + Az1:2002
PN-A-82055-5: 1994
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 11290-1:2017-07
PN-EN ISO 11290-2:2017-07
PN-EN ISO 11731:2017-08 +AP1:2019-12
PN-EN ISO 11885:2009
PN-EN ISO 16266:2009
PN-EN ISO 4833-1: 2013-12+Ap1:2016-11+A1:2022-06
PN-EN ISO 6222:2004
PN-EN ISO 6579-1:2017-04 + A1:2020-09
PN-EN ISO 6888-2:2022-03 + A1:2024-02
PN-EN ISO 6888-3:2004+AC:2005
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+Ap1:2015-06 Method C
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 - cl. 10 and 11
PN-ISO 16649-2:2004
PN-ISO 4832:2007
PN-ISO 6059:1999
PN-ISO 9297:1994
PN-N-01307:1994
PN-Z-04008-7:2002
PN-Z-04008-7:2002+Ap1:2004
PN-Z-04016:2005-10
PN-Z-04023-02:1989
PN-Z-04469:2015-10
PN-Z-04472:2015-10
PN-Z-04472:2015-10/AP1:2015-12
PN-Z-04487:2017-10
PN-Z-04507:2022-05
PN-Z-04508:2022-05
Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201087