🇵🇱 ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. w OŁAWIE PL

PCA AB 1081 • Oława, Poland • 25 methods

Water & wastewaterMicrobiology

ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. w OŁAWIE is a laboratory accredited by PCA under number AB 1081 (Oława, Poland). Its accreditation scope covers 25 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Wastewater, Water, water intended for human consumption, wastewater, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, MPN method (Colilert 18 test).

At a glance

  • Accreditation number: PCA AB 1081
  • Methods in scope: 25
  • Types of test objects: 4
  • Techniques used: 11
  • City: Oława, Poland
Accreditation number
AB 1081
Accreditation body
PCA
Address
ul. 3 Maja 30, 55-200 Oława, LABORATORIUM WODNO-ŚCIEKOWE, ul. Rybacka 31, 55-200 Oława
City
Oława, Poland

What this laboratory tests (4)

Analytical techniques used (11)

Laboratory locations

Certificate information

Issue date
22.05.2026
Issue no.
17

Accreditation scope — test methods (25)

No. Test object Methodology / Parameters Technique Reference document
Water and Wastewater Laboratory
1 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
2 Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 excluding cl. 4.4.3 to 4.4.6
3 Water, water intended for human consumption Total iron concentration
Range (0,10 – 5,0) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
4 Water, water intended for human consumption Manganese concentration
Range (0,030 – 1,0) mg/l
Spectrophotometric method PN-92/C-04590.03
5 Water, water intended for human consumption Chloride concentration
Range (6 – 150) mg/l
Titrimetric method PN-ISO 9297:1994
6 Water, water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (0,06 – 6,00) mmol/l
Titrimetric method PN-ISO 6059:1999
7 Water, water intended for human consumption Electrical conductivity
Range (100 – 3000) μS/cm
Conductometric method PN-EN 27888:1999
8 Water, water intended for human consumption Turbidity
Range (0,5 – 10) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
9 Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04
10 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04
11 Water, water intended for human consumption Most probable number, Escherichia coli MPN method (Colilert 18 test) PN-EN-ISO 9308-2:2014-06
12 Water, water intended for human consumption Most probable number of coliform bacteria MPN method (Colilert 18 test) PN-EN-ISO 9308-2:2014-06
13 Water, water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
14 Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
15 Water, water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
16 Wastewater Sampling for chemical testing and physical properties Manual method; Automatic method PN-ISO 5667-10:2021-11
17 Wastewater Chemical oxygen demand - COD
Range (6 – 7000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
18 Wastewater Biochemical oxygen demand
BOD5 Range (3 – 2000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
19 Wastewater Total suspended solids (TSS)
Range (2 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
20 Wastewater Total nitrogen concentration
Range (1 – 200) mg/l
Spectrophotometric method PB-04 issue III of 11.04.2016 | based on the Hach Lange cuvette test No. LCK 138, LCK 238 and LCK 338
21 Wastewater Total phosphorus concentration
Range (0,06 – 20) mg/l
Spectrophotometric method PB-09 issue III of 11.04.2016 | based on the Hach Lange cuvette test No. LCK 348, LCK 349 and LCK 350
22 Water, water intended for human consumption, wastewater Ammonium nitrogen concentration
Range (0,08 – 100) mg/l Ammonium ion concentration Range (0,1 – 128,8) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
23 Water, water intended for human consumption, wastewater Nitrite nitrogen concentration
Range (0,036 – 1) mg/l Nitrite concentration Range (0,12 – 3,29) mg/l
Spectrophotometric method PN-EN 26777:1999
24 Water, water intended for human consumption, wastewater Nitrate nitrogen concentration
Range (0,04 – 11) mg/l Nitrate concentration Range (0,18 – 48,7) mg/l
Spectrophotometric method PN-82/C-04576.08
25 Water, water intended for human consumption, wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012

Reference standards (25)

PB-04 issue III of 11.04.2016
PB-09 issue III of 11.04.2016
PN-82/C-04576.08
PN-92/C-04590.03
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 excluding cl. 4.4.3 to 4.4.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12/A1:2017-04
PN-EN-ISO 9308-1:2014-12
PN-EN-ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994
based on the Hach Lange cuvette test No. LCK 348, LCK 349 and LCK 350
based on the Hach Lange cuvette test No. LCK 138, LCK 238 and LCK 338

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201081