🇵🇱 PRACOWNIA SPECJALISTYCZNA OCHRONY ŚRODOWISKA PL

PCA AB 1066 • Zabrze, Poland • 71 methods

Environment

PRACOWNIA SPECJALISTYCZNA OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 1066 (Zabrze, Poland). Its accreditation scope covers 71 test methods in the following areas: Environment. Test objects include: Waste gases, Automated Measuring Systems (AMS), Ambient air - immission, Waste gas dedusting equipment. Most frequently used techniques: Non-dispersive infrared spectrometry NDIR, Gravimetric method, Potentiometric titration method.

At a glance

  • Accreditation number: PCA AB 1066
  • Methods in scope: 71
  • Types of test objects: 4
  • Techniques used: 18
  • City: Zabrze, Poland
Accreditation number
AB 1066
Accreditation body
PCA
Address
„SILECO” S. C. Kazimierz Bek, Przemysław Bek, Patrycja Tylutko, ul. Wolności 191, 41-800 Zabrze
City
Zabrze, Poland

What this laboratory tests (4)

Analytical techniques used (18)

Laboratory locations

Certificate information

Issue date
10.06.2026
Issue no.
20

Accreditation scope — test methods (71)

No. Test object Methodology / Parameters Technique Reference document
Specialist Environmental Protection Laboratory "SILECO" S. C.; Kazimierz Bek, Przemysław Bek, Patrycja Tylutko
1 Waste gases Gas volume flow rate for dynamic pressures > 10 Pa
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Stagnation pressure method PN-Z-04030-7:1994
2 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-Z-04030-7:1994
3 Waste gases Dust concentration
Range (0,001 – 100) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gravimetric method PN-Z-04030-7:1994
4 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-Z-04030-7:1994
5 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13284-1:2018-02
6 Waste gases Dust concentration
Range (1,0 – 50) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gravimetric method PN-EN 13284-1:2018-02
7 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13284-1:2018-02
8 Waste gases Concentration of carbon monoxide, nitrogen oxide, sulphur dioxide, carbon dioxide
CO (2,0 – 1250) mg/m3 SO2 (5,0 – 2860) mg/m3 CO2 (0,1 – 21) %
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Non-dispersive infrared spectrometry NDIR PN-ISO 10396:2001
9 Waste gases Nitrogen oxides concentration (NOx)
Range (3,0 – 1300) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Chemiluminescence method CLD PN-ISO 10396:2001
10 Waste gases Oxygen concentration
Range (0,1 – 25) %
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Paramagnetic method PMD PN-ISO 10396:2001
11 Waste gases Emission of CO, NO (calculated as NO2), SO2, CO2 (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-ISO 10396:2001
12 Waste gases Nitrogen oxides concentration (NOx)
Range (3 – 1300) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Chemiluminescence method PN-EN 14792:2006
13 Waste gases NOx emission (NO and NO2 expressed as NO2) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 14792:2006
14 Waste gases Sampling for determination of SO2 concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 14791:2017-04
15 Waste gases Sulphur dioxide concentration
Range (5 – 2000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Thoron method PN-EN 14791:2017-04
16 Waste gases SO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 14791:2017-04
17 Waste gases Oxygen concentration
Range (0,1 – 25) %
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Paramagnetic method PN-EN 14789:2006
18 Waste gases Carbon monoxide concentration
Range (0,15 – 1250) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Non-dispersive infrared spectrometry NDIR PN-EN 15058:2006
19 Waste gases Water vapour content
Range (29 – 250) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Condensation-adsorption method PN-EN 14790:2017-04
20 Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (5 – 250) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Continuous flame ionization detection method (FID) PN- EN 12619:2013-05
21 Waste gases Emission of organic substances in the form of gases and vapours expressed as total gaseous organic carbon (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN- EN 12619:2013-05
22 Waste gases Gas velocity and volume flow rate for differential pressures > 5 Pa
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Differential pressure measurement method PN-EN ISO 16911-1:2013-07
23 Waste gases Sampling for the determination of mercury concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13211+AC:2006
24 Waste gases Mercury emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13211+AC:2006
25 Waste gases Sampling for determination of concentrations of organic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Aspiration method using activated carbon / silica gel / absorbing solutions PN-Z-04008-4:1999
26 Waste gases Emission of organic compounds (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-Z-04008-4:1999
27 Waste gases Sampling for the determination of concentrations of individual gaseous organic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13649:2005
28 Waste gases Emission of individual gaseous organic compounds (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13649:2005
29 Waste gases Sampling for determination of hydrogen chloride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 1911:2011
30 Waste gases Hydrogen chloride concentration
Range (1 – 5000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Potentiometric titration method PN-EN 1911:2011
31 Waste gases Hydrogen chloride emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 1911:2011
32 Waste gases Sampling for determination of hydrogen fluoride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
ISO 15713:2006
33 Waste gases Hydrogen fluoride concentration
Range (0,1 – 200) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Potentiometric titration method ISO 15713:2006
34 Waste gases Hydrogen fluoride emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
ISO 15713:2006
35 Waste gases Sampling for determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 14385:2025-05
36 Waste gases Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 14385:2025-05
37 Automated Measuring Systems (AMS) AMS calibration (QAL2) for: dust, NOx, SO2, CO2, CO, O2, H2O, HCl, HF, organic substances in the form of gases and vapours expressed as total gaseous organic carbon, Hg
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 14181:2015-02
38 Automated Measuring Systems (AMS) Annual surveillance test (AST) for: dust, NOx, SO2, CO2, CO, O2, H2O, HCl, HF, organic substances in the form of gases and vapours expressed as total gaseous organic carbon, Hg
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 14181:2015-02
39 Automated Measuring Systems (AMS) Dust concentration
Range (0,001 – 100) g/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gravimetric method PN-Z-04030-7:1994
40 Automated Measuring Systems (AMS) NOx concentration
Range (3,0 – 1300) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Chemiluminescence method PN-EN 14792:2006
41 Automated Measuring Systems (AMS) SO2 concentration
Range (5,0 – 2000) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Thoron method PN-EN 14791:2017-04
42 Automated Measuring Systems (AMS) CO concentration
Range (0,15 – 1250) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Non-dispersive infrared spectrometry NDIR PN-EN 15058:2006
43 Automated Measuring Systems (AMS) CO2 concentration
Range (0,1 – 21) %
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Non-dispersive infrared spectrometry NDIR PN-ISO 10396:2001
44 Automated Measuring Systems (AMS) O2 concentration
Range (0,1 – 21) %
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Paramagnetic method PN-EN 14789:2006
45 Automated Measuring Systems (AMS) Water vapour content
Range (29 – 250) g/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Condensation-adsorption method PN-EN 14790:2017-04
46 Automated Measuring Systems (AMS) HCl concentration
Range (1 – 5000) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Potentiometric titration method PN-EN 1911:2011
47 Automated Measuring Systems (AMS) HF concentration
Range (0,1 – 200) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Potentiometric method ISO 15713:2006
48 Automated Measuring Systems (AMS) Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (5 – 250) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Continuous flame ionisation detection method (FID) PN-EN 12619:2013-05
49 Automated Measuring Systems (AMS) Sampling for the determination of mercury concentration
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13211+AC:2006
50 Ambient air - immission Dust sampling for testing ASTM D 1739:98 (2017)
51 Ambient air - immission Dust deposition
Range (0,5 – 980) g/m2
Deposition method (settling particulate matter) ASTM D 1739:98 (2017)
52 Waste gases Sampling for determination of NH3 concentration PN-EN ISO 21877:2020-03
53 Waste gases NH3 emission (calculated) PN-EN ISO 21877:2020-03
54 Waste gases Sampling for the determination of Se, Zn concentration Aspiration method using filters and absorbing solutions PN-EN 14385:2025-05 | PB-3 issue C of 03.04.2026
55 Waste gases Emission of metals: Se, Zn (calculated) PN-EN 14385:2025-05 | PB-3 issue C of 03.04.2026
56 Waste gases Sampling for determination of formaldehyde concentration Aspiration method using absorbing solutions PB-4 issue B of 26.05.2025
57 Waste gases Formaldehyde emission (calculated) PB-4 issue B of 26.05.2025
58 Waste gases Sampling for determination of hydrogen sulphide concentration PB-5 issue B of 26.05.2025
59 Waste gases Hydrogen sulphide emission (calculated) PB-5 issue B of 26.05.2025
60 Waste gases Nitrous oxide (N2O) concentration
Range ( 1 – 200 ) mg/m3
Non-dispersive infrared spectrometry NDIR PN-EN ISO 21258:2010
61 Waste gases N2O emission (calculated) PN-EN ISO 21258:2010
62 Waste gases Sampling for determination of SO3 VDI 2462-2:2011
63 Waste gases SO3 concentration
Range (5,0 - 50) mg/m3
Thoron method VDI 2462-2:2011
64 Waste gases SO3 emission (calculated) VDI 2462-2:2011
65 Automated Measuring Systems (AMS) Calibration of AMS (QAL2) for: NH3, N2O PN-EN 14181:2015
66 Automated Measuring Systems (AMS) Annual surveillance test (AST) for: NH3, N2O PN-EN 14181:2015
67 Automated Measuring Systems (AMS) Sampling for determination of NH3 concentration PN-EN ISO 21877:2020-03
68 Automated Measuring Systems (AMS) NH3 emission (calculated) PN-EN ISO 21877:2020-03
69 Automated Measuring Systems (AMS) Nitrous oxide (N2O) concentration
Range ( 1 – 200 ) mg/m3
Non-dispersive infrared spectrometry NDIR PN-EN ISO 21258:2010
70 Waste gas dedusting equipment Dust concentration
Range (0,001 – 100) g/m3
Gravimetric method PN-Z-04030-7:1994
71 Waste gas dedusting equipment Dust removal efficiency (calculated) PN-Z-04030-7:1994

Reference standards (26)

ASTM D 1739:98 (2017)
ISO 15713:2006
PB-3 issue C of 03.04.2026
PB-4 issue B of 26.05.2025
PB-5 issue B of 26.05.2025
PN- EN 12619:2013-05
PN-EN 12619:2013-05
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14181:2015
PN-EN 14181:2015-02
PN-EN 14385:2025-05
PN-EN 14789:2006
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2006
PN-EN 15058:2006
PN-EN 1911:2011
PN-EN ISO 16911-1:2013-07
PN-EN ISO 21258:2010
PN-EN ISO 21877:2020-03
PN-ISO 10396:2001
PN-Z-04008-4:1999
PN-Z-04030-7:1994
VDI 2462-2:2011

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201066