🇵🇱 PRZEDSIĘBIORSTWO USŁUG KOMUNALNYCH Sp. z o.o. PL

PCA AB 1063 • Gryfino, Poland • 46 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO USŁUG KOMUNALNYCH Sp. z o.o. is a laboratory accredited by PCA under number AB 1063 (Gryfino, Poland). Its accreditation scope covers 46 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Wastewater, Wastewater, water intended for human consumption, Sewage sludge, activated sludge. Most frequently used techniques: Spectrophotometric method, Gravimetric method, MPN method.

At a glance

  • Accreditation number: PCA AB 1063
  • Methods in scope: 46
  • Types of test objects: 5
  • Techniques used: 11
  • City: Gryfino, Poland
Accreditation number
AB 1063
Accreditation body
PCA
Address
ul. Targowa 16, 74-100 Gryfino, LABORATORIUM, ul. Łączna 1 AA
City
Gryfino, Poland

What this laboratory tests (5)

Analytical techniques used (11)

Laboratory sections (2)

Laboratory locations

Certificate information

Issue date
22.06.2026
Issue no.
20

Accreditation scope — test methods (46)

No. Test object Methodology / Parameters Technique Reference document
Physico-Chemical Testing Laboratory
1 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample (5 – 35) 0C
Manual and automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
2 Wastewater Ammonium nitrogen concentration
Range (0,05 – 100) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
3 Wastewater Ammonium nitrogen concentration
Ammonium nitrogen concentration (0,07 – 232) mg/l Ammonium ion concentration (0,10 – 300) mg/l
Spectrophotometric method PB-07.00 issue 4 of 17.12.2015 | based on HACH LANGE test LCK 304; LCK 305; LCK 302
4 Wastewater Total nitrogen concentration
Range (5,0 – 200) mg/l
Spectrophotometric method PB-01.00 issue 7 of 13.12.2017 | based on HACH LANGE test LCK 238; LCK 338
5 Wastewater Biochemical oxygen demand -BOD5
Range (0,50 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
6 Wastewater Biochemical oxygen demand -BOD5
Range (6 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
7 Wastewater Chemical oxygen demand - COD-Cr
Range (15 – 5000) mg/l O2
Spectrophotometric method PB-03.00 issue 5 of 17.12.2015 | based on HACH LANGE test LCK 314; LCK 514; LCK 014; LCK 1014
8 Wastewater Chemical oxygen demand (SP-COD)
Range (15,0 – 5000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
9 Wastewater Total phosphorus concentration
Total phosphorus concentration (0,32 – 19,5) mg/l Orthophosphate concentration (1,00 – 60) mg/l
Spectrophotometric method PB-04.00 issue 5 of 17.12.2015 | based on HACH LANGE test LCK 348; LCK 350
10 Wastewater Total phosphorus concentration
Range (0,06 – 19,5) mg/l
Spectrophotometric method PN-ISO 6878:2006 +Ap1:2010+Ap2:2010 cl. 7
11 Wastewater Total iron concentration
Range (0,20 – 100) mg/l
Spectrophotometric method PB-17.00 issue 2 of 17.12.2015 | based on HACH LANGE test LCK 321
12 Wastewater Sulfate concentration
Range (40 – 500) mg/l
Spectrophotometric method PB-05.00 issue 5 of 17.12.2015 | based on HACH LANGE test LCK 153; LCK 353
13 Wastewater Total suspended solids (TSS)
Range (5,0 – 5000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
14 Wastewater Anionic surfactants concentration
Range (0,10 – 40,0) mg/l
Spectrophotometric method PB-19.00 issue 3 of 17.12.2015 | based on HACH LANGE test LCK 332
15 Wastewater Concentration of non-ionic surfactants
Range (0,20 – 80) mg/l
Spectrophotometric method PB-16.00 issue 2 of 17.12.2015 | based on HACH LANGE test LCK 333
16 Wastewater Nitrate nitrogen concentration
Range (0,23 – 13,5) mg/l
Spectrophotometric method PB-21.00 issue 2 of 17.12.2015 | based on HACH LANGE test LCK 339
17 Wastewater Nitrite nitrogen concentration
Range (0,15 – 0,60) mg/l
Spectrophotometric method PB-22.00 issue 2 of 17.12.2015 | based on HACH LANGE test LCK 341
18 Wastewater Total iron concentration
Range (0,1 – 40) mg/l
Spectrophotometric method PN ISO 6332:2001 cl. 7.1.1
19 Wastewater, water intended for human consumption pH + Tests performed at and outside the laboratory premises
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
20 Wastewater, water intended for human consumption Chloride concentration
Range (5,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
21 Wastewater, water intended for human consumption Electrical conductivity + Tests performed at and outside the laboratory premises
Range (500 – 12900) µS/cm
Conductometric method PN-EN 27888:1999
22 Wastewater, water intended for human consumption Sulfate concentration
Range (10,0 – 500) mg/l
Gravimetric method PN-ISO 9280:2002
23 Sewage sludge, activated sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011
24 Sewage sludge, activated sludge pH
Range (4,0 – 10,0)
Potentiometric method PN-EN 12176:2004
25 Sewage sludge, activated sludge Dry residue/ water content
Range (1,0 – 50) %
Gravimetric method PN-EN 12880:2004
26 Activated sludge Total suspended solids (TSS)
Range (2000 – 10000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
27 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 excluding cl. 6.5
28 Water intended for human consumption Sulfate concentration
Range (40 – 500) mg/l
Spectrophotometric method PB-08.00 issue 4 of 09.07.2020 | based on HACH LANGE test LCK 153; LCK 353
29 Water intended for human consumption Ammonium ion concentration
Range (0,05 – 2,00) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
30 Water intended for human consumption Ammonium ion concentration
Range (0,10 – 2,0) mg/l
Spectrophotometric method PB-09.00 issue 4 of 09.07.2020 | based on HACH LANGE test LCK 304
31 Water intended for human consumption Free chlorine concentration
Range (0,15 – 0,75) mg/l
Colorimetric method PB-10.00 issue 4 of 09.07.2020 | based on the HACH LANGE method
32 Water intended for human consumption Nitrate concentration
Range (1,00 – 55) mg/l
Spectrophotometric method PB-11.00 issue 5 of 09.07.2020 | based on HACH LANGE test LCK 339
33 Water intended for human consumption Nitrite concentration
Range (0,020 – 1,0) mg/l
Spectrophotometric method PB-12.00 issue 4 of 14.07.2020 | based on HACH LANGE test LCK 341
34 Water intended for human consumption Iron concentration
Range (10 – 5000) µg/l
Spectrophotometric method PB-13.00 issue 4 of 14.07.2020 | based on HACH LANGE test LCK 521
35 Water intended for human consumption Manganese concentration
Range (20 – 1000) µg/l
Spectrophotometric method PB-14.00 issue 4 of 14.07.2020 | based on HACH LANGE test LCW 032
36 Water intended for human consumption Total hardness
Range (1,00 – 55,8) O dH Range (17,9 – 1000) mg/l CaCO3
Spectrophotometric method PB-15.00 issue 4 of 14.07.2020 | based on HACH LANGE test LCK 327
37 Water intended for human consumption Turbidity
Range (0,20 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
38 Water intended for human consumption Colour
Range (3,0 – 45,0) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 Method C
39 Water intended for human consumption Iron concentration
Range (10 – 2000) µg/l
Spectrophotometric method PN-ISO 6332:2001 cl. 7.2
40 Water intended for human consumption Permanganate index
Range (0,50 – 10,0) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
Microbiological Testing Laboratory
41 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 excluding cl. 4.4.3, 4.4.4, 4.4.5, 4.4.6
42 Water intended for human consumption MPN of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
43 Water intended for human consumption MPN of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
44 Water intended for human consumption MPN of enterococci MPN method PB-27.00 issue 3 of 03.04.2025
45 Water intended for human consumption Total count of microorganisms at 36 ⁰C Pour plate method PN-EN ISO 6222:2004
46 Water intended for human consumption Total count of microorganisms at 22 ⁰C Pour plate method PN-EN ISO 6222:2004

Reference standards (58)

PB-01.00 issue 7 of 13.12.2017
PB-03.00 issue 5 of 17.12.2015
PB-04.00 issue 5 of 17.12.2015
PB-05.00 issue 5 of 17.12.2015
PB-07.00 issue 4 of 17.12.2015
PB-08.00 issue 4 of 09.07.2020
PB-09.00 issue 4 of 09.07.2020
PB-10.00 issue 4 of 09.07.2020
PB-11.00 issue 5 of 09.07.2020
PB-12.00 issue 4 of 14.07.2020
PB-13.00 issue 4 of 14.07.2020
PB-14.00 issue 4 of 14.07.2020
PB-15.00 issue 4 of 14.07.2020
PB-16.00 issue 2 of 17.12.2015
PB-17.00 issue 2 of 17.12.2015
PB-19.00 issue 3 of 17.12.2015
PB-21.00 issue 2 of 17.12.2015
PB-22.00 issue 2 of 17.12.2015
PB-27.00 issue 3 of 03.04.2025
PN ISO 6332:2001 cl. 7.1.1
PN-77/C-04584
PN-EN 12176:2004
PN-EN 12880:2004
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 excluding cl. 4.4.3, 4.4.4, 4.4.5, 4.4.6
PN-EN ISO 5667-13:2011
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Method C
PN-EN ISO 8467:2001
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10 excluding cl. 6.5
PN-ISO 6332:2001 cl. 7.2
PN-ISO 6878:2006 +Ap1:2010+Ap2:2010 cl. 7
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
based on the HACH LANGE method
based on HACH LANGE test LCK 153; LCK 353
based on HACH LANGE test LCK 238; LCK 338
based on HACH LANGE test LCK 304
based on HACH LANGE test LCK 304; LCK 305; LCK 302
based on HACH LANGE test LCK 314; LCK 514; LCK 014; LCK 1014
based on HACH LANGE test LCK 321
based on HACH LANGE test LCK 327
based on HACH LANGE test LCK 332
based on HACH LANGE test LCK 333
based on HACH LANGE test LCK 339
based on HACH LANGE test LCK 341
based on HACH LANGE test LCK 348; LCK 350
based on HACH LANGE test LCK 521
based on HACH LANGE test LCW 032

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201063