🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL

PCA AB 106 • Warszawa, Poland • 34 methods

Water & wastewaterEnvironment

GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 106 (Warszawa, Poland). Its accreditation scope covers 34 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water, wastewater, Water, Environment – electromagnetic field in the vicinity of electric pow…, Soil. Most frequently used techniques: Spectrophotometric method, Direct measurement method, Optical method.

At a glance

  • Accreditation number: PCA AB 106
  • Methods in scope: 34
  • Types of test objects: 9
  • Techniques used: 16
  • City: Warszawa, Poland
Accreditation number
AB 106
Accreditation body
PCA
Address
ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W KIELCACH, Al. IX Wieków Kielc 3
City
Warszawa, Poland

What this laboratory tests (9)

Analytical techniques used (16)

Laboratory sections (3)

Laboratory locations

Certificate information

Issue date
17.04.2026
Issue no.
30

Accreditation scope — test methods (34)

No. Test object Methodology / Parameters Technique Reference document
FIELD LABORATORY
1 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 - 130) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws of 2023, item 1706) - excluding cl. F
2 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws of 2023, item 1706) - excluding cl. F
3 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength:
in the frequency range 50 Hz Range (1 - 30 000) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
4 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density:
in the frequency range 50 Hz Range 1 µT - 10 mT
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
5 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength
in the frequency range 50 Hz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
6 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Electric field strength:
in the frequency range from 10 MHz to 60 GHz Range (0,3 - 200) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
7 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength
in the frequency range from 10 MHz to 60 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
8 Water Water sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 excluding cl. 7.5; 7.6; 8.2
9 Wastewater Sampling of wastewater for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
10 Soil Sampling for chemical and physical testing PN-ISO 10381-5:2009
11 Soil pH in KCl
Range (4,0 - 9,0)
Potentiometric method PN-EN ISO 10390:2022-09
FIELD LABORATORY; tests performed outside the laboratory premises
12 Water Temperature
Range (0,0 - 50,0) 0C
PN-77/C-04584
13 Wastewater Temperature
Range (0,0 - 50,0) 0C
PN-77/C-04584
14 Water, wastewater pH
Range (2,0 - 12,0)
Potentiometric method PN-EN ISO 10523:2012
15 Water, wastewater Electrical conductivity
Range (10,0 - 10000) µS/cm
Conductometric method PN-EN 27888:1999
16 Water Dissolved oxygen concentration
Range (0,5 - 15,0) mg/l O2
Optical method ISO 17289:2014
LABORATORY IN KIELCE
17 Water, wastewater Nitrite nitrogen concentration
Range (0,002 - 20,0) mg/l
Spectrophotometric method PN-EN 26777:1999
18 Water, wastewater Kjeldahl nitrogen concentration
Range (0,30 - 500) mg/l
Titrimetric method PN-EN 25663:2001
19 Water, wastewater Kjeldahl nitrogen concentration
Range (1,00 - 500) mg/l
Potentiometric titration method PN-EN 25663:2001
20 Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14.
21 Water, wastewater Biochemical oxygen demand
BOD5, BOD2+5 Range (1 - 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
22 Water, wastewater Biochemical oxygen demand
BOD5, BOD2+5 Range (0,50 - 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
23 Water, wastewater Chemical oxygen demand - COD-Cr
Range (5,00 - 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005 excluding cl. 10.3
24 Water, wastewater Anion concentrations
nitrate nitrogen (0,10 - 100) mg/l fluorides (0,10 - 20) mg/l chlorides (10 - 1000) mg/l sulfates (10 - 1000) mg/l nitrite nitrogen (0,002 - 20) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
25 Water, wastewater Mineral oil index (petroleum hydrocarbons)
Range (0,10 - 5000) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
26 Water, wastewater Total phosphorus concentration
Range (0,010 - 50,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 cl. 7 +Ap1:2010+Ap2:2010
27 Water, wastewater Total suspended solids (TSS)
Range (2,0 - 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
28 Water, wastewater Ammonium nitrogen concentration
Range (0,04 - 100) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
29 Water Phosphate phosphorus concentration
Range (0,010 - 20,0) mg/l P
Spectrophotometric method PN-EN ISO 6878:2006 cl. 4. +Ap1:2010+Ap2:2010
30 Soil Water permeability – coefficient of permeability
Range (1,0·10-9 - 1,0·10-4) m/s
Hydraulic gradient method PN-EN ISO 17892-11:2019-05
31 Soil, ground Particle size distribution Sieve method PN-EN ISO 17892-4:2017-01
32 Soil, ground Particle size distribution Hydrometer method PN-EN ISO 17892-4:2017-01
33 Soil, ground Water permeability – coefficient of permeability
Range (9,0·10-8 - 1,8·10-2) m/s (calculated from the particle size distribution curve – USBSC formula)
PB-04/KI issue 2 of 09.12.2024
34 Water, wastewater *) Total organic carbon concentration
Range (2,0 - 1000) mg/l
Infrared spectrometry method (IR) PN-EN 1484:1999

Reference standards (26)

ISO 17289:2014
PB-04/KI issue 2 of 09.12.2024
PN-73/C-04576/14.
PN-77/C-04584
PN-EN 1484:1999
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 17892-11:2019-05
PN-EN ISO 17892-4:2017-01
PN-EN ISO 5667-6:2016-12 excluding cl. 7.5; 7.6; 8.2
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 cl. 4. +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 cl. 7 +Ap1:2010+Ap2:2010
PN-EN ISO 9377-2:2003
PN-ISO 10381-5:2009
PN-ISO 15705:2005 excluding cl. 10.3
PN-ISO 5667-10:2021-11
PN-ISO 7150-1:2002
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws of 2023, item 1706) - excluding cl. F

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20106