🇵🇱 MOBILNE LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o. PL

PCA AB 1054 • Wałbrzych, Poland • 58 methods

Construction

MOBILNE LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o. is a laboratory accredited by PCA under number AB 1054 (Wałbrzych, Poland). Its accreditation scope covers 58 test methods in the following areas: Construction. Test objects include: Windows and balcony doors E, Windows, balcony doors and external doors E, External doors E, Windows E. Most frequently used techniques: Calculation method, Method: measurement of the dynamic closing force using the weights….

At a glance

  • Accreditation number: PCA AB 1054
  • Methods in scope: 58
  • Types of test objects: 17
  • Techniques used: 2
  • City: Wałbrzych, Poland
Accreditation number
AB 1054
Accreditation body
PCA
Address
ul. Jana Kasprowicza 21 lok. 2, 58-300 Wałbrzych, ul. Wrocławska 142B, 58-306 Wałbrzych, (stacjonarna działalność techniczna)
City
Wałbrzych, Poland

What this laboratory tests (17)

Analytical techniques used (2)

Laboratory sections (2)

Laboratory locations

Certificate information

Issue date
09.04.2026
Issue no.
24

Accreditation scope — test methods (58)

No. Test object Methodology / Parameters Technique Reference document
MOBILNE LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o.; Stationary technical activity
1 Windows Casement hardware load test AAMA/WDMA/CSA 101/1.S.2/A440:22
2 Windows, shutters, balcony doors and doors, roller blinds, blinds, walls, gates E Dimensions
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Test procedure PB-01
3 Windows, balcony doors and external doors E Air permeability
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
PN-EN 1026 „N”
4 Windows, balcony doors and external doors E Watertightness
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
PN-EN 1027 „N”
5 Windows, balcony doors and external doors E Flexural strength by compression of welded corners
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 514
6 Windows, balcony doors and external doors E Thermal transmittance
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Calculation method PN-EN ISO 10077-1 „N” | PN-EN ISO 10077-2 „N”
7 Windows, balcony doors and external doors E Resistance to wind load
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
PN-EN 12211 „N”
8 Windows and balcony doors E Sound insulation
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Calculation method PN-EN 14351-1 „N”
9 Windows and balcony doors E Resistance to static torsion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 14609
10 Windows and balcony doors E Load-bearing capacity of safety devices
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
PN-EN 14609 „N” | PN-EN 14351-1
11 Windows and balcony doors E Operating forces
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 12046-1
12 Windows and balcony doors E Resistance to load in the plane of the leaf
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 14608
13 Doors E Operating forces
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Method: measurement of the dynamic closing force using the weights method PN-EN 12046-2
14 External doors E Resistance to static torsion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 948
15 External doors E Load-bearing capacity of safety devices
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
PN-EN 948 „N” | PN-EN 14351-1
16 Internal doors E Air permeability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 1026
17 Internal doors E Thermal transmittance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Calculation method PN-EN ISO 10077-1 | PN-EN ISO 10077-2
18 Sections of curtain wall frames E Thermal transmittance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Calculation method PN-EN ISO 12631 | PN-EN ISO 10077-2
19 Blinds E Thermal transmittance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Calculation method PN-EN ISO 10077-2
20 Windows, doors, balcony doors E Resistance to static load
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 1628
21 Windows, doors, balcony doors E Resistance to dynamic load
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 1629
22 Windows, doors, balcony doors E Resistance to manual burglary attempts
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 1630
23 External and internal doors, Windows, roof windows, shutters, blinds, glass panes, External walls, internal walls, gates and their components, Curtain walls, Building, ventilation and other components with an area of less than 1m2 E Sound insulation
Range of centre frequencies of 1/3 oct. bands (50 ÷ 5000) Hz
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
PN-EN ISO 10140-1 ,,N” | PN-EN ISO 10140-2 ,,N” | PN-EN ISO 10140-4 | PN-EN ISO 10140-5
24 External and internal doors, Windows, roof windows, shutters, blinds, glass panes, External walls, internal walls, gates and their components, Curtain walls, Building, ventilation and other components with an area of less than 1m2 E Single-number airborne sound reduction index together with the spectrum adaptation terms (calculated)
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
PN-EN ISO 717-1 ,,N”
25 Windows, external doors E Structural performance by uniform static air pressure difference
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
ASTM E330/E330M | AAMA/WDMA/CSA 101/1.S.2/A440
26 Windows, external doors E Determining the rate of air leakage under specified pressure differences across the specimen
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
ASTM E283/E283M | AAMA/WDMA/CSA 101/1.S.2/A440 | CSA A440S1
27 Windows, external doors E Water penetration by uniform static air pressure difference
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
ASTM E331 | AAMA/WDMA/CSA 101/1.S.2/A440 | CSA A440S1
28 Windows, external doors E Water penetration by cyclic static air pressure difference
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
ASTM E547 | AAMA/WDMA/CSA 101/1.S.2/A440 | CSA A440S1
29 Windows, external doors E Operating force
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
ASTM E2068 | AAMA/WDMA/CSA 101/1.S.2/A440 | CSA A440S1
30 Windows, external doors E Strength of welded PVC joints, Thermoplastic corner weld test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
AAMA/WDMA/CSA 101/1.S.2/A440
31 Windows E Deglazing test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
ASTM E987 | AAMA/WDMA/CSA 101/1.S.2/A440
32 Windows E Forced entry resistance test
Range Grade 10, 20, 30, 40 Scope Grade 10, 20, 30, 40
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
ASTM F588 | AAMA/WDMA/CSA 101/1.S.2/A440
33 Windows E Sash/leaf torsion test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
AAMA/WDMA/CSA 101/1.S.2/A440
34 Windows E Awning, hopper, projected hardware load test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
AAMA/WDMA/CSA 101/1.S.2/A440
35 Windows E Sash/leaf concentrated load test on the latch rail
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
AAMA/WDMA/CSA 101/1.S.2/A440
36 Windows E Stabilizing arm load test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
AAMA/WDMA/CSA 101/1.S.2/A440
37 External doors E Force-to-latch test procedure (for latch)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
AAMA/WDMA/CSA 101/1.S.2/A440
38 External doors E Force and torque required to throw the deadbolt, Force-to-engage test procedure (for deadbolt)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
AAMA/WDMA/CSA 101/1.S.2/A440
39 Windows, external doors, curtain walls E Missile impact resistance, Windborne debris in hurricanes (Impact test)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
ASTM E1996
40 Windows, external doors, curtain walls E Cyclic pressure differentials
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
ASTM E1886
41 Wall cladding, glass blocks, exterior doors, garage doors, skylights, exterior windows, storm shutters and any other external components which help maintain the integrity of the building envelope E Missile impact resistance, Impact test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Testing Application Standard (Tas) 201
42 Wall cladding, glass blocks, exterior doors, garage doors, skylights, exterior windows, storm shutters and any other external components which help maintain the integrity of the building envelope E Uniform static air pressure difference
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Testing Application Standard (Tas) 202
43 Wall cladding, glass blocks, exterior doors, garage doors, skylights, exterior windows, storm shutters and any other external components which help maintain the integrity of the building envelope E Cyclic wind pressure loading
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Testing Application Standard (Tas) 203
MOBILNE LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o.; Tests performed outside the Laboratory premises
44 Windows, shutters, balcony doors and doors, roller blinds, blinds, walls, gates E Dimensions
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Test procedure PB-01
45 Windows, balcony doors and external doors E Air permeability
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
PN-EN 1026 „N”
46 Windows, balcony doors and external doors E Watertightness
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
PN-EN 1027 „N”
47 Windows, balcony doors and external doors E Resistance to wind load
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
PN-EN 12211 „N”
48 Internal doors E Air permeability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 1026
49 Windows and balcony doors E Resistance to static torsion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 14609
50 Windows and balcony doors E Load-bearing capacity of safety devices
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
PN-EN 14609 „N” | PN-EN 14351-1
51 Windows and balcony doors E Operating forces
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 12046-1
52 Windows and balcony doors E Resistance to load in the plane of the leaf
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 14608
53 Doors E Operating forces
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Method: measurement of the dynamic closing force using the weights method PN-EN 12046-2
54 External doors E Resistance to static torsion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 948
55 External doors E Load-bearing capacity of safety devices
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. "N" – Test method used in activities relevant to notification under Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
PN-EN 948 „N” | PN-EN 14351-1
56 Curtain walls, external windows and doors E Watertightness
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
PN-EN 13051
Test methods
57 Doors, windows, shutters, blinds and related building hardware ASSESSMENT OF PERFORMANCE ON THE BASIS OF TESTS, CALCULATIONS AND TABULATED VALUES (System 3)
Commission decision number 99/93/WE Product(s) Doors, windows, shutters, blinds and related building hardware Harmonised technical specifications EN 14351-1:2006+A2:2016
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. The laboratory meets the requirements of Regulation No 305/2011 of 9 March 2011 for the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope. The current "List of subcontractors" is available on request at any time from the accredited body.
EN 14351-1:2006+A2:2016 | Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ L 88 of 4.4.2011 as amended)
58 ASSESSMENT OF PERFORMANCE
Essential characteristic Sound insulation Technical specification EN ISO 10140-1:2021-10
Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision 99/93/EC. The laboratory meets the requirements of Regulation No 305/2011 of 9 March 2011 for the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope.
EN ISO 10140-1:2021-10 | Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ L 88 of 4.4.2011 as amended)

Reference standards (47)

AAMA/WDMA/CSA 101/1.S.2/A440
AAMA/WDMA/CSA 101/1.S.2/A440:22
ASTM E1886
ASTM E1996
ASTM E2068
ASTM E283/E283M
ASTM E330/E330M
ASTM E331
ASTM E547
ASTM E987
ASTM F588
CSA A440S1
EN 14351-1:2006+A2:2016
EN ISO 10140-1:2021-10
PN-EN 1026
PN-EN 1026 „N”
PN-EN 1027 „N”
PN-EN 12046-1
PN-EN 12046-2
PN-EN 12211 „N”
PN-EN 13051
PN-EN 14351-1
PN-EN 14351-1 „N”
PN-EN 14608
PN-EN 14609
PN-EN 14609 „N”
PN-EN 1628
PN-EN 1629
PN-EN 1630
PN-EN 514
PN-EN 948
PN-EN 948 „N”
PN-EN ISO 10077-1
PN-EN ISO 10077-1 „N”
PN-EN ISO 10077-2
PN-EN ISO 10077-2 „N”
PN-EN ISO 10140-1 ,,N”
PN-EN ISO 10140-2 ,,N”
PN-EN ISO 10140-4
PN-EN ISO 10140-5
PN-EN ISO 12631
PN-EN ISO 717-1 ,,N”
Test procedure PB-01
Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ L 88 of 4.4.2011 as amended)
Testing Application Standard (Tas) 201
Testing Application Standard (Tas) 202
Testing Application Standard (Tas) 203

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201054