🇵🇱 WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ PL

PCA AB 1042 • Wrocław, Poland • 48 methods

EnvironmentWater & wastewaterAutomotive

WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ is a laboratory accredited by PCA under number AB 1042 (Wrocław, Poland). Its accreditation scope covers 48 test methods in the following areas: Environment, Water & wastewater, Automotive. Test objects include: Water intended for human consumption, Workplace environment - air, Workplace environment - electromagnetic field in the workspace from…, Workplace environment - electromagnetic field in the workspace orig….

At a glance

  • Accreditation number: PCA AB 1042
  • Methods in scope: 48
  • Types of test objects: 20
  • City: Wrocław, Poland
Accreditation number
AB 1042
Accreditation body
PCA
Address
WE WROCŁAWIU, ZESPÓŁ LABORATORYJNY, ul. Ślężna 158
City
Wrocław, Poland

What this laboratory tests (20)

Accreditation scope — test methods (48)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - indoor electric lighting Illuminance Range: (5-10 000) lx Direct measurement method PN-83/E-4040.03 PB-01/LBŚP issue 3 of 07.03.2023
2 Workplace environment - indoor electric lighting Lighting uniformity ( calculated)
3 Workplace environment - noise A-weighted equivalent sound level A-weighted maximum sound level Range: (35 – 135) dB C-weighted peak sound level Range: (35 – 135) dB Direct measurement method PN-N-01307:1994 PN-ISO 9612:2011 excluding the method covering strategy 2
4 Workplace environment - noise Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)
5 Workplace environment - air Air sampling for occupational exposure assessment to dust agents - inhalable fraction Personal dosimetry method PN-Z-04008-7:2002
6 Workplace environment - air Exposure index (calculated)
7 Workplace environment - air Concentration of harmful dust agents - inhalable fraction - wood dust Range (0,30 – 30,0) mg/m3 Gravimetric method PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
8 Workplace environment - moderate microclimate Air temperature Range: (5 – 40) °C Black globe temperature Range: (5 – 40) °C Air humidity Range: (25 – 80) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method PN-EN ISO 7730:2006 + Ap:2016-04
9 Workplace environment - moderate microclimate PMV index PPD index (calculated)
10 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Electric field strength: - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 600 MHz range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | …Health at Work. Protection against electromagnetic radiation. Part 2: Test methods
11 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength - from 1,6 MHz to 600 MHz Range: (0,01 – 15,0) A/m Direct measurement method
12 Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Electric field strength: - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 18 GHz range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | …Health at Work. Protection against electromagnetic radiation. Part 2: Test methods
13 Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Magnetic field strength from 1,6 MHz to 1 GHz Range: (0,01 – 15,0) A/m Direct measurement method
14 Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Magnetic field strength from 1 GHz to 18 GHz (calculated)
15 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Electric field strength - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 600 MHz range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | …Health at Work. Protection against electromagnetic radiation. Part 2: Test methods
16 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Magnetic field strength - from 1,6 MHz to 10 MHz range: (0,02 - 110) A/m - from 10 MHz to 30 MHz range: (0,02 - 15) A/m - from 27 MHz to 600 MHz range: (0,01 – 2,0) A/m Direct measurement method
17 Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Electric field strength - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 1 GHz Range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | …Health at Work. Protection against electromagnetic radiation. Part 2: Test methods
18 Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Magnetic field strength from 1,6 MHz to 1 GHz range: (0,015 – 15) A/m Direct measurement method
19 Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Electric field strength: - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 18 GHz range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | …Health at Work. Protection against electromagnetic radiation. Part 2: Test methods
20 Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Magnetic field strength from 1,6 MHz to 1 GHz Range: (0,01 – 15,0) A/m Direct measurement method
21 Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Magnetic field strength from 1 GHz to 18 GHz (calculated)
22 Workplace environment - electromagnetic field in the workspace from medical magnetotherapy equipment Magnetic flux density in the frequency range - from 20 Hz to 50 Hz range: (0,020 – 50,0) mT Direct (simplified) measurement method Magnetic field strength in the frequency range from 20 Hz to 50 Hz (calculated) Principles and Methods of Assessing the Working Environment 2016, No. 4, pp. 151- 180
23 Canned products in metal packaging – meat and meat products Shelf stability of canned products Incubation method PN-A-82055-5:1994 excluding cl. 2.5.3., excluding sampling
24 Canned products in metal packaging – meat and meat products Leak tightness of cans Vacuum method PN-A-82055-4:1997+Az1:2002 excluding cl. 2.4.1.3
25 Canned products in tin packaging – fruit, vegetable and vegetable-meat preserves Shelf stability of canned products Incubation method PN-90/A-75052/03
26 Canned products in tin packaging – fruit, vegetable and vegetable-meat preserves Leak tightness of cans Vacuum method PN-90/A-75052/02 excluding cl. 2.2.3
27 Canned products in tin packaging – canned fish Shelf stability of canned products Incubation method PN – 92/A-86732 cl. 2.3.11, excluding sampling
28 Canned products in tin packaging – canned fish Leak tightness of cans Vacuum method PN – 92/A-86732 cl. 2.3.10. excluding sampling
29 Canned products in hermetically sealed packaging Sterilised soups Shelf stability of canned products Incubation method NO-89-A208:2015 cl. 4.6 PN – 90/A – 75052 -03
30 Canned products in hermetically sealed packaging Sterilised soups Leak tightness of cans Vacuum method NO-89-A208:2015 cl. 4.7
31 Canned products in hermetically sealed packaging Sterilised canned poultry Shelf stability of canned products Incubation method NO-89-A203 | PN-A-82055-5:1994 excluding cl. 2.5.3., excluding sampling
32 Canned products in hermetically sealed packaging Sterilised canned poultry Leak tightness of cans Vacuum method NO-89-A203 | PN-A-82055-4:1997 + Az1:2002 excluding cl. 2.4.1.3.
33 Canned products in hermetically sealed packaging Sterilised canned vegetable – meat and meatless products Shelf stability of canned products Incubation method NO-89-A202:2015 cl. 4.6 PN - 90/A - 75052-03:1990
34 Canned products in hermetically sealed packaging Sterilised canned vegetable – meat and meatless products Leak tightness of cans Vacuum method NO-89-A202:2015 cl. 4.7
35 Canned products in hermetically sealed packaging Sterilised canned meat Shelf stability of canned products Incubation method NO-89-A201 | PN-A-82055-5:1994 excluding cl. 2.5.3, excluding sampling
36 Canned products in hermetically sealed packaging Sterilised canned meat Leak tightness of cans Vacuum method NO-89-A201 | PN-A-82055 - 4:1997 + Az1:2002 excluding cl. 2.4.1.3
37 Water intended for human consumption pH Range: 4 – 10 Potentiometric method EN ISO 10523:2012
38 Water intended for human consumption Specific conductivity Range: (100 – 1500) μS/cm Conductometric method PN-EN 27888:1999
39 Water intended for human consumption Turbidity Range: (0, 1 – 40) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
40 Water intended for human consumption Iron concentration Range: (0,02– 1,0) mg/l Spectrophotometric method PB - 07/ LBŻiW issue 7 of 22.11.2016
41 Water intended for human consumption Manganese concentration Range: (0,02 – 0,1) mg/l Spectrophotometric method PB - 06/ LBŻiW issue 7 of 22.11.2016
42 Water intended for human consumption Nitrite nitrogen concentration Range: (0,01 – 0,15) mg/l Spectrophotometric method PB - 04/LBŻiW issue 8 of 22.03.2024
43 Water intended for human consumption Nitrite concentration Range: (0,033 – 0,495) mg/l (calculated)
44 Water intended for human consumption Ammonium nitrogen concentration Range: (0,03 – 0,40) mg/l Spectrophotometric method PB - 02/LBŻiW issue 8 of 22.03.2024
45 Water intended for human consumption Ammonium ion concentration Range: (0,04– 0,52) mg/l (calculated)
46 Water intended for human consumption Total count of microorganisms at 22ºC Plate method (pour plate) PN-EN ISO 6222:2004
47 Swimming pool water Total count of microorganisms at 36ºC Plate method (pour plate) PN-EN ISO 6222:2004
48 Faeces, rectal swab Presence of rods of the genus Salmonella, Shigella Culture method with biochemical and serological confirmation Test procedure No. PB – 01/LM issue No. 7 of 15.03.2022, based on the Recommendations of the National Institute of Public Health, PZH and KIDL, Warsaw 2015

Reference standards (32)

EN ISO 10523:2012
NO-06-A215-2
NO-89-A201
NO-89-A202:2015 cl. 4.6 PN - 90/A - 75052-03:1990
NO-89-A202:2015 cl. 4.7
NO-89-A203
NO-89-A208:2015 cl. 4.6 PN – 90/A – 75052 -03
NO-89-A208:2015 cl. 4.7
PB - 02/LBŻiW issue 8 of 22.03.2024
PB - 04/LBŻiW issue 8 of 22.03.2024
PB - 06/ LBŻiW issue 7 of 22.11.2016
PB - 07/ LBŻiW issue 7 of 22.11.2016
PN – 92/A-86732 cl. 2.3.10. excluding sampling
PN – 92/A-86732 cl. 2.3.11, excluding sampling
PN-83/E-4040.03 PB-01/LBŚP issue 3 of 07.03.2023
PN-90/A-75052/02 excluding cl. 2.2.3
PN-90/A-75052/03
PN-A-82055 - 4:1997 + Az1:2002 excluding cl. 2.4.1.3
PN-A-82055-4:1997 + Az1:2002 excluding cl. 2.4.1.3.
PN-A-82055-4:1997+Az1:2002 excluding cl. 2.4.1.3
PN-A-82055-5:1994 excluding cl. 2.5.3, excluding sampling
PN-A-82055-5:1994 excluding cl. 2.5.3., excluding sampling
PN-EN 27888:1999
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7730:2006 + Ap:2016-04
PN-N-01307:1994 PN-ISO 9612:2011 excluding the method covering strategy 2
PN-Z-04008-7:2002
PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
Principles and Methods of Assessing the Working Environment 2016, No. 4, pp. 151- 180
Test procedure No. PB – 01/LM issue No. 7 of 15.03.2022, based on the Recommendations of the National Institute of Public Health, PZH and KIDL, Warsaw 2015
…Health at Work. Protection against electromagnetic radiation. Part 2: Test methods

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201042