🇵🇱 ”LAB-SERWIS” LABORATORIUM BADAŃ ŚRODOWISKA S.C. PL
EnvironmentMaterials & polymers
”LAB-SERWIS” LABORATORIUM BADAŃ ŚRODOWISKA S.C. is a laboratory accredited by PCA under number AB 1004 (Częstochowa, Poland). Its accreditation scope covers 105 test methods in the following areas: Environment, Materials & polymers. Test objects include: Waste gases, Workplace environment – air, Waste gases, General environment – waste gas samples, Workplace environment – emergency lighting. Most frequently used techniques: Spectrophotometric method, Direct measurement method, Potentiometric method.
At a glance
- Accreditation number: PCA AB 1004
- Methods in scope: 105
- Types of test objects: 18
- Techniques used: 17
- City: Częstochowa, Poland
- Accreditation number
- AB 1004
- Accreditation body
- PCA
- Address
- ARTUR KAŁA, TOMASZ POLAK, LESZEK SIEROCIŃSKI, ul. Rejtana 23, 42-200 Częstochowa
- City
- Częstochowa, Poland
What this laboratory tests (18)
- Waste gases — 44 methods
- Workplace environment – air — 18 methods
- Waste gases, General environment – waste gas samples — 11 methods
- Workplace environment – emergency lighting — 4 methods
- Workplace environment – air – air samples collected into absorbing solution — 3 methods
- General environment – noise from installations, equipment and industrial plants — 2 methods
- General environment – waste gas samples — 2 methods
- Waste gas dedusting equipment — 2 methods
- Workplace environment – cold microclimate — 2 methods
- Workplace environment – energy expenditure — 2 methods
- Workplace environment – hand-arm vibration — 2 methods
- Workplace environment – hot microclimate — 2 methods
- Workplace environment – indoor electric lighting — 2 methods
- Workplace environment – moderate microclimate — 2 methods
- Workplace environment – noise — 2 methods
- and 3 more
Analytical techniques used (17)
- Spectrophotometric method — 18 methods
- Direct measurement method — 12 methods
- Potentiometric method — 6 methods
- Gravimetric method — 5 methods
- Turbidimetric method — 2 methods
- Aspiration method using absorbing solutions and membrane filters — 1 method
- Aspiration method using activated carbon/ silica gel/ absorbing solutions — 1 method
- Chemiluminescence method (CLD) — 1 method
- Continuous flame ionization detection method (FID) — 1 method
- Electrochemical method — 1 method
- Electrochemical method; Non-dispersive infrared spectrometry (NDIR) — 1 method
- Fourier transform infrared spectrometry (FT-IR) — 1 method
- Impaction method — 1 method
- Non-dispersive infrared spectrometry (NDIR) — 1 method
- Personal dosimetry method — 1 method
- and 2 more
Laboratory locations
- ”LAB-SERWIS” LABORATORIUM BADAŃ ŚRODOWISKA S.C. (main site) — ul. Rejtana 23, 42-200 Częstochowa
- ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński
Certificate information
- Issue date
- 16.04.2026
- Issue no.
- 30
Accreditation scope — test methods (105)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| ”Lab-Serwis” Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński | |||||
| 1 | Workplace environment – air | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction asbestos – respirable fibres man-made mineral fibres excluding refractory ceramic fibres – respirable fibres silicon carbide fibrous – respirable fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres |
Personal dosimetry method | PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 | |
| 2 | Workplace environment – air | Exposure index (calculated) | PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 | ||
| 3 | Workplace environment – air | Concentration of harmful dust agents – inhalable fraction apatites and phosphorites portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous silicon carbide, fibrous man-made mineral fibres excluding refractory ceramic fibres Range (0,1–20,5) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 4 | Workplace environment – air | Concentration of harmful dust agents – respirable fraction apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts diesel engine exhaust talc coal (hard, brown) Range (0,05 – 40,7) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 5 | Workplace environment – air | Nitrogen monoxide concentration/content Range (0,23 – 9,12) mg/m3 Range (0,18 – 7,31) ppm Range (0,0013 – 0,052) mg in the sample |
Spectrophotometric method | PN-Z-04009-11:2008 | |
| 6 | Workplace environment – air | Nitrogen dioxide concentration/content Range (0,07 – 7,11) mg/m3 Range (0,037 – 3,715) ppm Range (0,0004 – 0,016) mg in the sample |
Spectrophotometric method | PN-Z-04009-11:2008 | |
| 7 | Workplace environment – air | Nitric acid concentration/content (calculated) | PN-Z-04009-11:2008 | ||
| 8 | Workplace environment – air | Concentration of manganese and its inorganic compounds calculated as Mn inhalable fraction respirable fraction Range (0,006 – 1,5) mg/m3 |
Spectrophotometric method | ILR 10 issue 4 of 01.08.2018 | |
| 9 | Workplace environment – air | Concentration of iron oxides calculated as Fe – inhalable fraction – respirable fraction Range (0,07 – 166,6) mg/m3 |
Spectrophotometric method | ILR 10 issue 4 of 01.08.2018 | |
| 10 | Workplace environment – air | Carbon monoxide concentration Range (2,3 – 243,6) mg/m3 Range (2,0 – 210) ppm |
Electrochemical method | ILR 11 issue 2 of 16.11.2021 | |
| 11 | Workplace environment – air | Exposure indices (calculated) | ILR 11 issue 2 of 16.11.2021 | ||
| 12 | Workplace environment – air | Ammonia concentration/content Range (1,3 – 450) mg/m3 Range (0,02 – 2,25) mg in the sample |
Spectrophotometric method | PN-71/Z-04041 | |
| 13 | Workplace environment – air | Hydrogen chloride concentration/content Range (0,5 – 125,0) mg/m3 Range (0,01 – 2,50) mg in the sample |
Turbidimetric method | PN-93/Z-04225/03 | |
| 14 | Workplace environment – air | Concentration/content of fluorides Range (0,1 – 500) mg/m3 Range (0,002 – 10) mg in the sample |
Potentiometric method | ISO 15713-2006 | |
| 15 | Workplace environment – air | Fluoride concentration expressed as hydrogen fluoride (calculated) | ISO 15713-2006 | ||
| 16 | Workplace environment – air | Ozone concentration/content Range (0,01 – 0,25) mg/m3 Range (0,001 – 0,01) mg in the sample |
Spectrophotometric method | PN-Z-04007-2:1994 | |
| 17 | Workplace environment – air | Concentration/content of chromium VI Range (0,002 – 1,6) mg/m3 Range (0,002 – 0,08) mg in the sample |
Spectrophotometric method | PN-87/Z-04126.03 | |
| 18 | Workplace environment – air | Formaldehyde concentration/content Range (0,05 – 10,0) mg/m3 Range (0,001 – 0,02) mg in the sample |
Spectrophotometric method | PN-Z-04045-04:1976 | |
| 19 | Workplace environment – air – air samples collected on filters | Crystalline silica (quartz, cristobalite) concentration/content respirable fraction Range (0,0063 – 1,26) mg/m3 Range (0,005 – 1,0) mg in the sample |
Fourier transform infrared spectrometry (FT-IR) | Principles and Methods of Assessing the Working Environment 2012, issue 4 (74), pp. 117-130 | |
| 20 | Workplace environment – air – air samples collected into absorbing solution | Concentration/content of hydrogen cyanide and cyanides calculated as CN- Range (0,1 – 20) mg/m3 Range (0,09 – 17,8) ppm Range (0,0005 – 0,1) mg in the sample |
Potentiometric method | PN-70/Z-04053 | ILR 16 issue 1 of 01.03.2021 | |
| 21 | Workplace environment – air – air samples collected into absorbing solution | Concentration/content of phosphorus decaoxide (phosphorus pentoxide) Range (0,1 – 5) mg/m3 Range (0,001 – 0,02) mg in the sample |
Spectrophotometric method | PN-Z-04073-1:2014-8 | |
| 22 | Workplace environment – air – air samples collected into absorbing solution | Phosphoric acid content (calculated) | PN-Z-04073-1:2014-8 | ||
| 23 | Workplace environment – indoor electric lighting | Illuminance Range (0,5 – 10000) lx |
Direct measurement method | PN-83/E-04040.03 | ILR 7 issue 2 of 30.10.2023 | |
| 24 | Workplace environment – indoor electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ILR 7 issue 2 of 30.10.2023 | ||
| 25 | Workplace environment – emergency lighting | Illuminance Range (0,5 – 500) lx |
Direct measurement method | PN-EN 1838:2013-11 excluding cl. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5 | |
| 26 | Workplace environment – emergency lighting | Closing time Range (4 – 9000) s |
Direct measurement method | PN-EN 1838:2013-11 excluding cl. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5 | |
| 27 | Workplace environment – emergency lighting | Ratio of minimum to maximum illuminance (calculated) | PN-EN 1838:2013-11 excluding cl. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5 | ||
| 28 | Workplace environment – emergency lighting | Illuminance uniformity for the high-risk zone (calculated) | PN-EN 1838:2013-11 excluding cl. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5 | ||
| 29 | Workplace environment – energy expenditure | Air temperature Range (5 – 35) °C Air flow Range (10 – 59) dm3/min |
Direct measurement method | ILR 14 issue 1 of 10.07.2018 | |
| 30 | Workplace environment – energy expenditure | Energy expenditure (calculated) | ILR 14 issue 1 of 10.07.2018 | ||
| 31 | Workplace environment – hot microclimate | Air temperature Range (15 – 60) °C Natural wet bulb temperature Range (15 – 42) °C Black globe temperature Range (15 – 60) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 32 | Workplace environment – hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | ||
| 33 | Workplace environment – moderate microclimate | Air temperature Range (10 – 42) °C Black globe temperature Range (10 – 42) °C Air humidity Range (13 – 85) % Air velocity Range (0,15 – 1,5) m/s |
Direct measurement method | PN-EN ISO 7730:2006 | |
| 34 | Workplace environment – moderate microclimate | PMV and PPD index (calculated) | PN-EN ISO 7730:2006 | ||
| 35 | Workplace environment – cold microclimate | Air temperature Range (-29 – 10) °C Black globe temperature Range (-29 – 15) °C Air humidity Range (13,0 – 85,0) % Air velocity Range (0,15 – 5,0) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 36 | Workplace environment – cold microclimate | IREQmin index, IREQneutral index, twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 37 | Workplace environment – hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,3 – 100) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 38 | Workplace environment – hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 39 | Workplace environment – whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,03 – 35,5) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 40 | Workplace environment – whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 41 | Workplace environment – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (30 – 135) dB C-weighted peak sound pressure level Range (60 – 138) dB |
Direct measurement method | PN-N-01307:1994 | PN-ISO 9612:2025-11 excluding the method covering strategy 3 - cl. 11 | |
| 42 | Workplace environment – noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-ISO 9612:2025-11 excluding the method covering strategy 3 - cl. 11 | ||
| 43 | Workplace environment – ultrasonic noise | Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz Range (40 – 140) dB |
Direct measurement method | PN-Z-01339:2020-12 | |
| 44 | Workplace environment – ultrasonic noise | Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-Z-01339:2020-12 | ||
| 45 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (24 – 135) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F | |
| 46 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F | ||
| 47 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa Velocity: Range (0,1 – 30) m/s Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Stagnation pressure method; Thermoanemometric method | PN-Z-04030-7:1994 | |
| 48 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 49 | Waste gases | Dust concentration Range (0,001 – 70) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-Z-04030-7:1994 | |
| 50 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 51 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13284-1:2018-02 | ||
| 52 | Waste gases | Dust concentration Range (0,0001 – 0,050) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 53 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13284-1:2018-02 | ||
| 54 | Waste gases | Concentration of oxygen, sulphur dioxide, carbon monoxide, carbon dioxide O2 (2,0 – 21) % SO2 (2,86 – 3000) mg/m3 CO2 (0,1 – 15) % Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Electrochemical method; Non-dispersive infrared spectrometry (NDIR) | PN-ISO 10396:2001 | |
| 55 | Waste gases | Emission of SO2, CO2 (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-ISO 10396:2001 | ||
| 56 | Waste gases | Nitrogen oxides concentration NOx (2,0 – 2000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Chemiluminescence method (CLD) | PN-EN 14792:2017-04 | PN-ISO 10396:2001 | |
| 57 | Waste gases | NOx emission (NO and NO2 expressed as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14792:2017-04 | PN-ISO 10396:2001 | ||
| 58 | Waste gases | Carbon monoxide concentration CO (1,25 – 3750) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2017-04 | PN-ISO 10396:2001 | |
| 59 | Waste gases | CO emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 15058:2017-04 | PN-ISO 10396:2001 | ||
| 60 | Waste gases | Sampling for determination of hydrogen chloride concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1911:2011 | ||
| 61 | Waste gases | Hydrogen chloride concentration Range (0,08 – 75) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Spectrophotometric method | PN-EN 1911:2011 | |
| 62 | Waste gases | HCl emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1911:2011 | ||
| 63 | Waste gases | Sampling for determination of hydrogen fluoride concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 15713:2006 | ||
| 64 | Waste gases | Hydrogen fluoride concentration Range (0,02 – 100) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Potentiometric method | ISO 15713:2006 | |
| 65 | Waste gases | HF emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 15713:2006 | ||
| 66 | Waste gases | Sampling for determination of total mercury concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13211+AC:2006 | ||
| 67 | Waste gases | Total mercury emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13211+AC:2006 | ||
| 68 | Waste gases | Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14385:2005 | ||
| 69 | Waste gases | Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14385:2005 | ||
| 70 | Waste gases | Sampling for the determination of organic compound concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Aspiration method using activated carbon/ silica gel/ absorbing solutions | PN-Z-04008-4:1999 | |
| 71 | Waste gases | Emission of organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04008-4:1999 | ||
| 72 | Waste gases | Sampling for determination of sulfur dioxide Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14791:2017-04 | ||
| 73 | Waste gases | Sulphur dioxide concentration Range (2,0 – 2000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Thoron method | PN-EN 14791:2017-04 | |
| 74 | Waste gases | Sulphur dioxide emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14791:2017-04 | ||
| 75 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (2,0 – 1000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013-05 | |
| 76 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 12619:2013-05 | ||
| 77 | Waste gases | Sampling for the determination of PCDD/PCDF concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1948-1:2006 | ||
| 78 | Waste gases | PCDD/PCDF emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1948-1:2006 | ||
| 79 | Waste gases | Sampling for determination of the concentration of PM 2,5 and PM 10 dust | PN-EN ISO 23210:2010 | ||
| 80 | Waste gases | PM 2,5 and PM 10 dust concentration Range (0,6 – 40) mg/m3 |
Impaction method | PN-EN ISO 23210:2010 | |
| 81 | Waste gases | PM 2,5 and PM 10 dust emission (calculated) | PN-EN ISO 23210:2010 | ||
| 82 | Waste gases | Sampling for determination of metal concentrations: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se | ILR 34 issue 1 of 04.04.2014 | ||
| 83 | Waste gases | Emission of metals: Sb, As, Ba, Cr, Zn, Sn, Al, Cd, Co, Mn, Cu, Mo, Ni, Pb, Ti, Ag, V, Fe, Bi, K, Li, Na, Se (calculated) | ILR 34 issue 1 of 04.04.2014 | ||
| 84 | Waste gases | Sampling for determination of the concentration of ammonia, chlorine, hydrogen cyanide, sulfuric acid, hydrogen sulfide, ozone | Aspiration method using absorbing solutions and membrane filters | ILR 33 issue 7 of 12.12.2022 | |
| 85 | Waste gases | Emission of ammonia, chlorine, hydrogen cyanide, sulphuric acid, hydrogen sulphide, ozone (calculated) | ILR 33 issue 7 of 12.12.2022 | ||
| 86 | Waste gases | Sampling for determination of the concentration of dioxin-like PCB (dioxins and furans) | PN-EN 1948-4:2013+A1:2014-03 | ||
| 87 | Waste gases | Emission of dioxin-like PCBs (dioxins and furans) (calculated) | PN-EN 1948-4:2013+A1:2014-03 | ||
| 88 | Waste gases | Sampling for determination of ammonia concentration | PN-EN ISO 21877:2020-03 | ||
| 89 | Waste gases | Ammonia concentration/content Range (0,08 – 83) mg/m3 Range (0,005 – 2,5) mg in the sample |
Spectrophotometric method | PN-EN ISO 21877:2020-03 | |
| 90 | Waste gases | Ammonia emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 91 | Waste gases, General environment – waste gas samples | Sampling for the determination of fluorine concentration | ISO 15713:2006 | ||
| 92 | Waste gases, General environment – waste gas samples | Concentration/content of fluorine Range (0,02– 100,00) mg/m3 Range (0,002 – 10,00) mg in the sample |
Potentiometric method | ISO 15713:2006 | |
| 93 | Waste gases, General environment – waste gas samples | Fluorine emission (calculated) | ISO 15713:2006 | ||
| 94 | Waste gases, General environment – waste gas samples | Concentration/content of hydrogen cyanide and cyanides calculated as CN- Range (0,02 – 33,33) mg/m3 Range (0,0005 – 0,1) mg in the sample |
Potentiometric method | PN-70/Z-04053 excluding cl. 7 | ILR 16 issue 1 of 01.03.2021 | |
| 95 | Waste gases, General environment – waste gas samples | Nitrogen monoxide concentration/content Range (0,07– 23,11) mg/m3 Range (0,0013-0,0104) mg in the sample |
Spectrophotometric method | PN-Z-04009-11:2008 excluding cl. 7 | |
| 96 | Waste gases, General environment – waste gas samples | Nitrogen dioxide concentration/content Range (0,02 – 7,11) mg/m3 Range (0,0004 – 0,016) mg in the sample |
Spectrophotometric method | PN-Z-04009-11:2008 excluding cl. 7 | |
| 97 | Waste gases, General environment – waste gas samples | Ammonia concentration/content Range (1,3 – 450) mg/m3 Range (0,02 – 2,25) mg in the sample |
Spectrophotometric method | PN-71/Z-04041 excluding cl. 7 | |
| 98 | Waste gases, General environment – waste gas samples | Concentration/content of sulfuric(VI) acid and sulfur trioxide Range (0,1 – 20) mg/m3 Range (0,1 – 10) mg in the sample |
Turbidimetric method | PN-91/Z-04056.02 excluding cl. 7 | |
| 99 | Waste gases, General environment – waste gas samples | Concentration/content of chromium (VI) Range (0,01 – 1,60) mg/m3 Range (0,002 – 0,08) mg in the sample |
Spectrophotometric method | PN-87/Z-04126.03 excluding cl. 7 | |
| 100 | Waste gases, General environment – waste gas samples | Formaldehyde concentration/content Range (0,03 – 10,0) mg/m3 Range (0,0005 – 0,20) mg in the sample |
Spectrophotometric method | PN-76/Z-04045.04 excluding cl. 7 | |
| 101 | Waste gases, General environment – waste gas samples | Ozone concentration/content Range (0,01 – 0,25) mg/m3 Range (0,001 – 0,01) mg in the sample |
Spectrophotometric method | PN-Z-04007-2:1994 excluding cl. 7 | |
| 102 | General environment – waste gas samples | Hydrogen chloride content Range (0,017 – 7,50) mg in the sample |
Spectrophotometric method | PN-EN 1911:2011 | |
| 103 | General environment – waste gas samples | Hydrogen fluoride content Range (0,002 – 10,00) mg in the sample |
Potentiometric method | ISO 15713:2006 | |
| 104 | Waste gas dedusting equipment | Dust concentration Range (0,001 – 100) g/m3 |
Gravimetric method | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129, Method A | |
| 105 | Waste gas dedusting equipment | Dust removal efficiency (calculated) | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129, Method A | ||
Reference standards (60)
ILR 10 issue 4 of 01.08.2018
ILR 11 issue 2 of 16.11.2021
ILR 14 issue 1 of 10.07.2018
ILR 16 issue 1 of 01.03.2021
ILR 33 issue 7 of 12.12.2022
ILR 34 issue 1 of 04.04.2014
ILR 7 issue 2 of 30.10.2023
ISO 15713-2006
ISO 15713:2006
PN-70/Z-04053
PN-70/Z-04053 excluding cl. 7
PN-71/Z-04041
PN-71/Z-04041 excluding cl. 7
PN-76/Z-04045.04 excluding cl. 7
PN-83/E-04040.03
PN-87/M-34129, Method A
PN-87/Z-04126.03
PN-87/Z-04126.03 excluding cl. 7
PN-91/Z-04056.02 excluding cl. 7
PN-93/Z-04225/03
PN-EN 12619:2013-05
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 14253+A1:2011
PN-EN 14385:2005
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 1838:2013-11 excluding cl. 4.2.3; 4.2.4; 4.2.7; 4.3.3; 4.3.4; 4.3.9; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 4.4.7; 5
PN-EN 1911:2011
PN-EN 1948-1:2006
PN-EN 1948-4:2013+A1:2014-03
PN-EN ISO 11079:2008
PN-EN ISO 21877:2020-03
PN-EN ISO 23210:2010
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-ISO 10396:2001
PN-ISO 9612:2025-11 excluding the method covering strategy 3 - cl. 11
PN-N-01307:1994
PN-Z-01339:2020-12
PN-Z-04007-2:1994
PN-Z-04007-2:1994 excluding cl. 7
PN-Z-04008-4:1999
PN-Z-04008-7:2002
PN-Z-04008-7:2002/Az1:2004
PN-Z-04009-11:2008
PN-Z-04009-11:2008 excluding cl. 7
PN-Z-04030-7:1994
PN-Z-04045-04:1976
PN-Z-04073-1:2014-8
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Principles and Methods of Assessing the Working Environment 2012, issue 4 (74), pp. 117-130
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F