🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL

PCA AB 085 • Warszawa, Poland • 100 methods

Water & wastewaterEnvironment

GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 085 (Warszawa, Poland). Its accreditation scope covers 100 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water Wastewater, Water, Sewage sludge Waste O): code 19 08 05, Soil.

At a glance

  • Accreditation number: PCA AB 085
  • Methods in scope: 100
  • Types of test objects: 13
  • City: Warszawa, Poland
Accreditation number
AB 085
Accreditation body
PCA
Address
ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W ŁODZI, ul. Lipowa 16
City
Warszawa, Poland

What this laboratory tests (13)

Laboratory locations

Certificate information

Issue date
21.10.2025
Issue no.
24

Accreditation scope — test methods (100)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water Chromium (Cr+6) concentration Range: (0,003 – 0,50) mg/l Spectrophotometric method PN-EN ISO 18412:2007
2 Water Dissolved phosphate concentration Range: (0,03 – 50,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 cl. 4 + Ap1:2010+Ap2:2010
3 Water Mercury concentration: Range: (0,0200 – 0,300) µg/l Cold vapour atomic spectrometry method with fluorescence detection (CVAFS) PN-EN ISO 17852:2009
4 Water Cyanide concentration Range: Total cyanides (0,008 – 0,10) mg/l Free cyanides (0,008 – 0,10) mg/l Flow analysis method with spectrophotometric detection (CFA) PN-EN ISO 14403-2:2012
5 Water Element concentrations Range: Antimony (0,10 – 100) µg/l Arsenic (1,00 – 100) µg/l Barium (1,00 – 1000) µg/l Beryllium (0,10 – 100) µg/l Boron (5,00 – 10000) µg/l Total chromium (1,00 – 100) µg/l Tin (1,00 – 100) µg/l Zinc (1,00 – 1000) µg/l Aluminium (5,00 – 10000) µg/l Cadmium (0,020 – 100) µg/l Cobalt (1,00 – 100) µg/l Magnesium (0,050 – 100) mg/l Manganese (1,00 – 10000) µg/l Copper (1,00 – 1000) µg/l Molybdenum (1,00 – 100) µg/l Nickel (1,00 – 1000) µg/l Lead (0,30 – 100) µg/l Potassium (0,050 – 100) mg/l Selenium (5,00 – 100) µg/l Sodium (0,050 – 100) mg/l Silver (1,00 – 100) µg/l Thallium (0,10 – 100) µg/l Vanadium (1,00 – 100) µg/l Calcium (0,10 – 200) mg/l Iron (5,00 – 10000) µg/l Titanium (1,00 – 100) µg/l Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
6 Water Concentration of polycyclic aromatic hydrocarbons Range: Benzo(a)pyrene (0,00012 – 2,0) µg/l Benzo(b)fluoranthene (0,0013 – 2,0) µg/l Benzo(k)fluoranthene (0,0013 – 2,0) µg/l Anthracene (0,003 – 2,0) µg/l Fluoranthene (0,002 – 2,0) µg/l Naphthalene (0,002 – 2,0) µg/l Benzo(g,h,i)perylene (0,0012 – 2,0) µg/l Indeno(1,2,3-cd)pyrene (0,0011 – 2,0) µg/l Dibenzo(a,h)anthracene (0,003 – 2,0) µg/l High performance liquid chromatography method with fluorescence detection (HPLC–FLD) Sum of PAH (calculated) PN-EN ISO 17993:2005
7 Wastewater Concentration of polycyclic aromatic hydrocarbons Range: Benzo(a)pyrene (0,003 – 2,0) µg/l Benzo(b)fluoranthene (0,003 – 2,0) µg/l Benzo(k)fluoranthene (0,003 – 2,0) µg/l Benzo(g,h,i)perylene (0,003 – 2,0) µg/l Indeno(1,2,3-cd)pyrene (0,003 – 2,0) µg/l Dibenzo(a,h)anthracene (0,003 – 2,0) µg/l High performance liquid chromatography method with fluorescence detection (HPLC–FLD) Sum of PAH (calculated) PN-EN ISO 17993:2005
8 Wastewater Mercury concentration Range: (0,000200 – 1,00) mg/l Atomic absorption spectrometry with amalgamation technique EPA METHOD 7473 02.2007
9 Wastewater Element concentrations Range: Antimony (0,0100 – 10,0) mg/l Arsenic (0,0100 – 10,0) mg/l Barium (0,0100 – 10,0) mg/l Beryllium (0,0100 – 10,0) mg/l Boron (0,0500 – 10,0) mg/l Total chromium (0,0100 – 10,0) mg/l Tin (0,0100 – 10,0) mg/l Zinc (0,0500 – 10,0) mg/l Aluminium (0,100 – 10,0) mg/l Cadmium (0,0010 – 10,0) mg/l Cobalt (0,0100 – 10,0) mg/l Manganese (0,0100 – 10,0) mg/l Copper (0,0100 – 10,0) mg/l Molybdenum (0,0100 – 10,0) mg/l Nickel (0,0100 – 10,0) mg/l Lead (0,0100 – 10,0) mg/l Selenium (0,0500 – 10,0) mg/l Silver (0,0100 – 10,0) mg/l Thallium (0,0100 – 10,0) mg/l Vanadium (0,0100 – 10,0) mg/l Iron (0,100 – 10,0) mg/l Titanium (0,0100 – 10,0) mg/l Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
10 Water Wastewater Total organic carbon (TOC) concentration Range: (1,00 – 500) mg/l Infrared range spectrometry method IR PN-EN 1484:1999
11 Water Wastewater Nitrite nitrogen concentration − N NO2 Range: (0,004 – 2,0) mg/l Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
12 Water Wastewater Nitrite concentration – NO2 (calculated)
13 Water Wastewater Kjeldahl nitrogen concentration Range: (0,5 – 50,0) mg/l Titrimetric method PN-EN 25663:2001
14 Water Wastewater Total nitrogen concentration Sum of N , N and N kjeld NO2 NO3 (calculated) PB-21/LO, issue 3 of 01.08.2025
15 Water Wastewater Phosphate concentration Range: (0,03 – 20,0) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
16 Water Wastewater Phosphate phosphorus concentration – P (calculated)
17 Water Wastewater Total suspended solids Range: (2 – 1000) mg/l Gravimetric method PN-EN 872:2007 + Ap1:2007
18 Water Wastewater Chromium (Cr+6) concentration Range: (0,02 – 2,0) mg/l Spectrophotometric method PN-77/C-04604/08
19 Water Wastewater Anion concentrations: Range: Chlorides (3,5 – 500) mg/l Sulfates (2,0 – 500) mg/l Nitrites (0,25 – 20,0) mg/l Nitrite nitrogen concentration – NNO2 (calculated) Nitrates (1,7 – 100) mg/l Nitrate nitrogen concentration – NNO3 (calculated) Fluorides (0,15 – 10,0) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012
20 Water Wastewater Total phosphorus concentration Range: (0,05 – 25,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
21 Water Wastewater Biochemical oxygen demand - BOD5 Range: (3,0 – 6000) mg/l O2 Electrochemical method PN-EN ISO 5815-1:2019-12
22 Water Wastewater Biochemical oxygen demand - BOD5 Range: (0,50 – 8,0) mg/l O2 Electrochemical method PN-EN 1899-2:2002
23 Water Wastewater Chemical oxygen demand COD-Cr Range: (10,0 – 1000) mg/l Spectrophotometric method PN-ISO 15705:2005
24 Water Wastewater Mineral oil index Range: (0,06 – 500) mg/l Gas chromatography with flame ionisation detection (GC-FID) PN-ISO 9377-2:2003
25 Soil Mercury content Range: (0,0300 – 2,00) mg/kg Atomic absorption spectrometry with amalgamation technique EPA METHOD 7473 02.2007
26 Soil Content of elements Range: Arsenic (0,2 – 400) mg/kg Barium (2,0 – 400) mg/kg Total chromium (0,2 – 400) mg/kg Zinc (2,0 – 400) mg/kg Cadmium (0,2 – 400) mg/kg Cobalt (0,2 – 400) mg/kg Copper (2,0 – 400) mg/kg Molybdenum (0,2 – 400) mg/kg Nickel (0,2 – 400) mg/kg Lead (0,2 – 400) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) method PN-EN 16173:2012 PN-EN 16171:2017-02
27 Soil Tin content Range: (2,0 – 400) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 16174:2012 PN-EN 16171:2017-02
28 Sewage sludge Waste O): code 19 08 05 Mercury content Range: (0,0300 – 2,00) mg/kg Atomic absorption spectrometry with amalgamation technique EPA METHOD 7473 02.2007
29 Sewage sludge Waste O): code 19 08 05 Content of elements Range: Arsenic (0,2 – 400) mg/kg Total chromium (0,2 – 400) mg/kg Zinc (2,0 – 400) mg/kg Cadmium (0,2 – 400) mg/kg Copper (2,0 – 400) mg/kg Nickel (0,2 – 400) mg/kg Lead (0,2 – 400) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) method PN-EN 16171:2017-02
30 Sewage sludge Waste O): code 19 08 05 Calcium content Range: (0,2 – 200) g/kg (0,02 – 20,0) % Magnesium content Range: (0,02 – 20,0) g/kg (0,002 – 2,0) % Inductively coupled plasma mass spectrometry (ICP-MS) method PN-EN 16171:2017-02
31 Water Biochemical oxygen demand - BOD5 Range: (3,0 – 200) mg/l O2 Electrochemical method PN-EN ISO 5815-1:2019-12
32 Water Permanganate index Range: (0,5 – 100) mg/l O2 Titrimetric method PN-EN ISO 8467:2001
33 Water Colour Range: (5 – 70) mg/l Pt Visual method PN-EN ISO 7887:2012 Method D
34 Water Total phosphorus concentration Range: (0,02 – 4,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010
35 Wastewater Biochemical oxygen demand - BOD5 Range: (3,0 – 6000) mg/l O2 Electrochemical method PN-EN ISO 5815-1:2019-12
36 Wastewater Total phosphorus concentration Range: (0,02 – 400) mg/l Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
37 Water Wastewater Biochemical oxygen demand - BOD5 Range: (0,5 – 6,0) mg/l O2 Electrochemical method PN-EN 1899-2:2002
38 Water Wastewater Total nitrogen concentration (calculated) PB-28/LO, issue 3 of 01.08.2025
39 Water Wastewater Concentration of substances extractable with petroleum ether Range: (1,0 – 2500) mg/l Gravimetric method PB-27/LO, issue 3 of 01.08.2025
40 Water Wastewater Total suspended solids Range: (2 – 2000) mg/l Gravimetric method PN-EN 872:2007 +Ap1:2007
41 Water Wastewater Phosphate concentration Range: (0,05 – 12) mg/l Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
42 Water Wastewater Phosphate concentration Range: (0,06 – 10) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
43 Water Wastewater Nitrate nitrogen concentration Range: (0,30 – 50) mg/l Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
44 Water Wastewater Nitrate concentration – NO 3 (calculated)
45 Water Wastewater Ammonium nitrogen concentration Range: (0,10 – 10) mg/l Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 11732:2007
46 Water Wastewater Concentration of ammonium ion, ammonia (calculated)
47 Water Wastewater Nitrite nitrogen concentration Range: (0,007 – 1,0) mg/l Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
48 Water Wastewater Un-ionised ammonia concentration (calculated) PB-29/LO, issue 3 of 01.08.2025
49 Water Wastewater Ammonium nitrogen concentration Range: (0,040 – 100) mg/l Spectrophotometric method PN-ISO 7150-1:2002
50 Water Wastewater Kjeldahl nitrogen concentration Range: (0,5 – 250) mg/l Spectrophotometric method PN-EN 25663:2001
51 Water Wastewater Chemical oxygen demand - COD-Cr Range: (30,0 – 6000) mg/l O2 Titrimetric method PN-ISO 6060:2006
52 Water Wastewater Chemical oxygen demand - COD-Cr Range: (9,0 – 150) mg/l O2 Spectrophotometric method PN-ISO 15705:2005
53 Water Wastewater Phenol concentration (phenol index) Range: (0,0015 – 5,00) mg/l Continuous flow analysis method (CFA) with spectrophotometric detection PN-EN ISO 14402:2004
54 Soil, waste O): code 19 08 05 Kjeldahl nitrogen content Range: (0,12 – 64) g/kg Spectrophotometric method PB-35/LO, issue 3 of 01.08.2025
55 Soil Content of organic substances, mineral substances Range: (100 – 850) g/kg (10 – 85) % Gravimetric method PB-34/LO, issue 3 of 01.08.2025
56 Soil Dry matter content / water content Range: (10 – 95) % Gravimetric method PN-ISO 11465:1999
57 Soil pH – in KCl, pH - in H2O Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10390:2022-09
58 Sewage sludge, waste O): code 19 08 05 pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10390:2022-09
59 Sewage sludge, waste O): code 19 08 05 Kjeldahl nitrogen content Range: (3,0 – 64) g/kg (0,3 – 6,4) % Spectrophotometric method PN-EN 13342:2002
60 Sewage sludge, waste O): code 19 08 05 Dry matter content / water content Range:(10 – 90) % (100 – 900) g/kg Gravimetric method PN-EN 12880:2004
61 Sewage sludge, waste O): code 19 08 05 Total phosphorus content Range: (1,0 – 20,0) g/kg (0,1 – 2,0) % Spectrophotometric method PN-EN 14672:2006 PN-EN ISO 6878:2006
62 Sewage sludge, waste O): code 19 08 05 Loss on ignition (organic matter content) Range: (5,0 – 90,0)% Gravimetric method PN-EN 15935:2022-01
63 Sewage sludge, waste O): code 19 08 05 Ammonium nitrogen content Range: (0,40 – 20,0) g/kg (0,04 – 2,00) % Spectrophotometric method PB-42/LO, issue 2 of 01.08.2025
64 Water Colour Range: (5 – 70) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 Method C
65 Water Wastewater Ammonium nitrogen concentration Range: (0,030 – 100) mg/l Spectrophotometric method PN-ISO 7150-1:2002
66 Water Wastewater Nitrite nitrogen concentration Range: (0,001 – 5) mg/l Spectrophotometric method PN-EN 26777:1999
67 Water Wastewater Kjeldahl nitrogen concentration Range: (1 – 150) mg/l Titrimetric method PN-EN 25663:2001
68 Water Wastewater Total nitrogen concentration (calculated) PB-08/LO, issue 3 of 01.08.2025
69 Water Wastewater Total phosphorus concentration Range: (0,005 – 50) mg/l Spectrophotometric method PN-EN ISO 6878:2006 cl. 7
70 Water Wastewater Dissolved orthophosphate concentration Range: (0,005 – 50,0) mg/l P Spectrophotometric method PN-EN ISO 6878:2006 cl. 4 +Ap2:2010
71 Water Wastewater Total suspended solids Range: 2 mg/l – 3 g/l Gravimetric method PN-EN 872:2007 + Ap1:2007
72 Water Wastewater Anionic surfactants (MBAS index) Range: (0,06 – 5) mg/l Spectrophotometric method PN-EN 903:2002
73 Water Wastewater Chemical oxygen demand COD-Cr Range: 7,5 mg/l O2 - 5 g/l O2 Spectrophotometric method PN-ISO 15705:2005
74 Soil Dry matter Range: (60,0 – 99,9)% Water content Range: (0,1 – 40,0)% Gravimetric method PN-ISO 11465:1999
75 Soil pH - in KCl Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10390:2022-09
76 Sewage sludge Waste O): code 19 08 05 Total phosphorus content Range: (0,1 – 2,5) % (1,0 – 25) g/kg Spectrophotometric method PN-EN14672:2006 PN-EN ISO 6878:2006 cl. 8 +Ap1:2010+Ap2:2010
77 Sewage sludge Waste O): code 19 08 05 Ammonium nitrogen content Range: (0,050 – 1,5) % Spectrophotometric method PB-14/LO, issue 4 of 01.08.2025
78 Sewage sludge Waste O): code 19 08 05 Kjeldahl nitrogen content Range: (0,01 – 5)% Spectrophotometric method PN-EN 13342:2002
79 Sewage sludge Waste O): code 19 08 05 pH - in H2O Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10390:2022-09
80 Sewage sludge Waste O): code 19 08 05 Dry residue, water content Range: (5 – 95)% Gravimetric method PN-EN 12880:2004
81 Sewage sludge Waste O): code 19 08 05 Loss on ignition of dry matter (LOI) / residue on ignition Range: (5,0 – 90,0)% Gravimetric method PN-EN 15935:2022-01
82 Sewage sludge Waste O): code 19 08 05 Presence and number of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp. Range: from 10 ATT eggs/kg d.m. Microscopic method PB-19/LO, issue 3 of 01.08.2025
83 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (26 - 135) dB Direct measurement method No. 7 | …regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding clause F
84 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
85 General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (26 - 135) dB Direct measurement method No. 8 | …regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023
86 General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
87 General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Range: (26 - 135) dB Direct measurement method No. 3 | …regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140 | No. 288 | …excluding clause H
88 General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
89 Water Sampling for physical and chemical testing Manual method Temperature of water/of the water sample taken Range: (0,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 PN-77/C-04584
90 Wastewater Sampling for physical and chemical testing Manual/ automatic method Temperature of wastewater/of the wastewater sample taken Range: (0,0 – 50,0) °C PN-ISO 5667-10:2021:11 PN-77/C-04584
91 Water Wastewater pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012
92 Water Wastewater Electrical conductivity Range: (10 - 20000) μS/cm Conductometric method PN-EN 27888:1999
93 Water Wastewater Dissolved oxygen concentration Range: (0,2 – 15,0) mg/l Electrochemical method PN-EN ISO 5814:2013-04
94 Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007 PN-ISO 10381-5:2009
95 Sewage sludge, Waste O): code 19 08 05 Sampling for physical, chemical and biological testing PN-EN ISO 5667-13:2011 excluding cl. 6.3.3
96 Environment - electromagnetic field in the vicinity of electric power substations and power lines Electric field strength: - in the frequency range 50 Hz Range: 1,0 V/m – 50 kV/m Direct measurement method …regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022
97 Environment - electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density: - in the frequency range 50 Hz Range 0,1 µT – 10 mT Direct measurement method
98 Environment - electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength: - in the frequency range 50 Hz (calculated)
99 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: - in the frequency range from 10 MHz to 3 GHz Range: (0,3 – 300) V/m - in the frequency range from 80 MHz to 60 GHz Range: (0,8 – 300) V/m Direct measurement method …regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022
100 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: - in the frequency range from 10 MHz to 60 GHz (calculated) …regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022

Reference standards (70)

EPA METHOD 7473 02.2007
No. 3
No. 8
PB-08/LO, issue 3 of 01.08.2025
PB-14/LO, issue 4 of 01.08.2025
PB-19/LO, issue 3 of 01.08.2025
PB-21/LO, issue 3 of 01.08.2025
PB-27/LO, issue 3 of 01.08.2025
PB-28/LO, issue 3 of 01.08.2025
PB-29/LO, issue 3 of 01.08.2025
PB-34/LO, issue 3 of 01.08.2025
PB-35/LO, issue 3 of 01.08.2025
PB-42/LO, issue 2 of 01.08.2025
PN-77/C-04604/08
PN-EN 12880:2004
PN-EN 13342:2002
PN-EN 14672:2006 PN-EN ISO 6878:2006
PN-EN 1484:1999
PN-EN 15935:2022-01
PN-EN 16171:2017-02
PN-EN 16173:2012 PN-EN 16171:2017-02
PN-EN 16174:2012 PN-EN 16171:2017-02
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007 + Ap1:2007
PN-EN 872:2007 +Ap1:2007
PN-EN 903:2002
PN-EN ISO 10304-1:2009 +AC:2012
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11732:2007
PN-EN ISO 13395:2001
PN-EN ISO 14402:2004
PN-EN ISO 14403-2:2012
PN-EN ISO 15681-2:2019-02
PN-EN ISO 17294-2:2024-04
PN-EN ISO 17852:2009
PN-EN ISO 17993:2005
PN-EN ISO 18412:2007
PN-EN ISO 5667-13:2011 excluding cl. 6.3.3
PN-EN ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 PN-77/C-04584
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 cl. 7
PN-EN ISO 6878:2006 cl. 4 + Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 cl. 4 +Ap2:2010
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 7887:2012 Method C
PN-EN ISO 7887:2012 Method D
PN-EN ISO 8467:2001
PN-EN14672:2006 PN-EN ISO 6878:2006 cl. 8 +Ap1:2010+Ap2:2010
PN-ISO 10381-4:2007 PN-ISO 10381-5:2009
PN-ISO 11465:1999
PN-ISO 15705:2005
PN-ISO 5667-10:2021:11 PN-77/C-04584
PN-ISO 6060:2006
PN-ISO 7150-1:2002
PN-ISO 9377-2:2003
…regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding clause F
…regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023
…regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022
…regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140
…excluding clause H
No. 288
No. 7