🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL

PCA AB 075 • Warszawa, Poland • 110 methods

Water & wastewaterEnvironmentMaterials & polymers

GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 075 (Warszawa, Poland). Its accreditation scope covers 110 test methods in the following areas: Water & wastewater, Environment, Materials & polymers. Test objects include: Water, wastewater, Waste gases, Sewage sludge, Soil.

At a glance

  • Accreditation number: PCA AB 075
  • Methods in scope: 110
  • Types of test objects: 21
  • City: Warszawa, Poland
Accreditation number
AB 075
Accreditation body
PCA
Address
ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ WE WROCŁAWIU
City
Warszawa, Poland

What this laboratory tests (21)

Laboratory locations

Certificate information

Issue date
13.01.2026
Issue no.
29

Accreditation scope — test methods (110)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Surface water Sampling for chemical and physical testing Temperature of water and of the water sample taken Range: (0,0 – 50,0) 0C PN-EN ISO 5667-6:2016-12 PN-77/C-04584
2 Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of wastewater and of the wastewater sample taken Range: (0,0 – 50,0) 0C PN-ISO 5667-10:2021-11 PN-77/C-04584
3 Rainwater Snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
4 Groundwater Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,0 – 50,0) 0C PN-EN ISO 5667-11:2017-10 excluding cl. 5.2 | PN-77/C-04584
5 Soil Sampling for chemical and physical testing ISO 10381-4:2007 PN ISO 10381-5:2009
6 Sewage sludge WasteO: code 19 08 05 Sampling for chemical, physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011
7 Water, wastewater pH Range: (2,0 – 12,0) Potentiometric method PN-EN ISO 10523:2012
8 Water, wastewater Electrical conductivity Range: (10 – 20000) μS/cm Conductometric method PN-EN 27888:1999
9 Water, wastewater Dissolved oxygen concentration Range: (0,3 – 20,0) mg/l O2 Electrochemical method PN-EN ISO 5814:2013-04
10 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (25 – 135) dB Measurement method: direct No. 7 | …regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 | …excluding clause F
11 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)
12 General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Range: (25 – 135) dB Measurement method: direct No. 3 | …regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140 | …excluding point H (Journal of Laws 2011 No. 288
13 General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)
14 General environment – impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level A-weighted maximum sound level A-weighted sound exposure level Range: (25 – 135) dB Direct measurement method No. 8 | …regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023
15 General environment – impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)
16 Waste Intervention testing (according to Programme DAB-11) PB-11/CLB issue 1 of 25.09.2023
17 WasteO): code 10 09 10, 19 01 12 Sampling for chemical and physical testing PB-05/WR issue 1 of 01.04.2021
18 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength at a frequency of 50 Hz Range: (100 – 50000) V/m Direct measurement method …regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630)
19 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density at a frequency of 50 Hz Range: 0,1 µT – 10 mT Direct measurement method
20 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength at 50 Hz frequency (calculated)
21 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: in the frequency range from 80 MHz to 60 GHz Range: (0,3 – 300) V/m Direct measurement method …regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630)
22 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: in the frequency range
23 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) from 80 MHz to 60 GHz
24 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) (calculated)
25 Waste gases Concentration of sulphur dioxide, nitrogen oxides, carbon monoxide, carbon dioxide and oxygen Range: SO (5,0 – 2860) mg/m3 2 CO (7,0 – 2500) mg/m3 CO (0,2 – 18,0) % 2 Non-dispersive infrared spectrometry method (NDIR) NO (2,0 – 925) mg/m3 x Chemiluminescence method O (0,2 – 21,0) % 2 Paramagnetic method PN-ISO 10396:2001
26 Waste gases Emission of SO , NO2 (NO x and NO2 calculated as NO2 ), CO, CO2 (calculated)
27 Waste gases Sampling for determination of dust concentration PN-Z-04030-7:1994
28 Waste gases Dust concentration Range: (0,001 – 10,0) g/m3 Gravimetric method
29 Waste gases Dust emission (calculated)
30 Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method Velocity Range: (1,0 – 10,0) m/s Thermoanemometric method
31 Waste gases Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005
32 Waste gases Emission of individual gaseous organic compounds (calculated)
33 Waste gases Sampling for determination of the concentrations of organic compounds Aspiration method using activated carbon/ silica gel PN-Z-04008-4:1999
34 Waste gases Emission of organic compounds (calculated)
35 Waste gases Concentration of organic substances in gaseous and vapour form expressed as total gaseous organic carbon Range: (2,0 – 1000) mg/m3 Continuous flame ionisation detection method (FID) PN-EN 12619:2013-05
36 Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)
37 Water, wastewater Total dissolved solids (TDS) Range: (20 – 10000) mg/l Gravimetric method PN-EN 15216:2022-03
38 Water, wastewater Total suspended solids (TSS) Range: (5,0 – 6000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
39 Water, wastewater Dissolved oxygen concentration Range: (0,3 – 20,0) mg/l O2 Titrimetric method PN-EN 25813:1997
40 Water, wastewater Biochemical oxygen demand - BOD , BOD5 2+5 Range: (1,0 – 6,0) mg/l O2 Electrochemical method PN-EN 1899-2:2002
41 Water, wastewater Biochemical oxygen demand - BOD , BOD5 2+5 Range: (5,0 – 6000) mg/l O2 Electrochemical method PN-EN ISO 5815-1:2019-12
42 Water, wastewater Chemical oxygen demand - COD-Cr Range: (5,0 – 9000) mg/l O2 Spectrophotometric method PN-ISO 15705:2005
43 Water, wastewater Anion concentrations Range: - chlorides (1,00 – 1000) mg/l - sulfates (1,0 – 1000) mg/l - nitrate nitrogen (0,113 – 50) mg/l - nitrates (0,50 – 221) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
44 Water, wastewater Ammonium nitrogen concentration Range: (0,050 – 250) mg/l N-NH4 (0,064 – 322) mg/l NH4 Flow analysis (CFA) with spectrometric detection PN-EN ISO 11732:2007
45 Water, wastewater Cation concentration Range: - sodium (1,0 – 1000) mg/l - potassium (0,50 – 1000) mg/l - magnesium (0,50 – 1000) mg/l - calcium (1,0 – 1000) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 14911:2002
46 Water, wastewater Total hardness (calculated) PB-03/WR issue 1 of 01.06.2021
47 Water, wastewater Nitrite nitrogen concentration Range: (0,005 – 5,00) mg/l N-NO2 (0,016 – 16,4) mg/l NO2 Flow analysis (CFA) with spectrometric detection PN-EN ISO 13395:2001
48 Water, wastewater Kjeldahl nitrogen concentration Range: (0,40 – 500) mg/l Titrimetric method PN-EN 25663:2001
49 Water, wastewater Total nitrogen concentration (calculated) PB-02/WR issue 1 of 01.06.2021
50 Water, wastewater Ammonium nitrogen concentration Range: (0,40 – 500) mg/l Ammonium ion concentration Range: (0,50 – 644) mg/l Titrimetric method PN-ISO 5664:2002
51 Water, wastewater Phenol index Range: (0,001 – 1,00) mg/l Flow analysis method (CFA) with spectrometric detection PN-EN ISO 14402:2004
52 Water, wastewater Total phosphorus concentration Range: (0,010 – 100) mg/l Flow analysis method (CFA) with spectrometric detection PN-EN 15681-2:2019-02
53 Water, wastewater Mineral oil index Range: (0,20 – 15,0) mg/l Gas chromatography with flame ionisation detection (GC-FID) PN-EN ISO 9377-2:2003
54 Water, wastewater Concentration of substances extractable with petroleum ether Range: (5,0 – 100) mg/l Gravimetric method PN-86/C-04573/01
55 Rainwater Snowmelt water Total suspended solids (TSS) Range: (5,0 – 6000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
56 Rainwater Snowmelt water Mineral oil index Range: (0,20 – 150) mg/l Gas chromatography with flame ionisation detection (GC-FID) PN-EN ISO 9377-2:2003
57 Soil, sewage sludge Mercury content Range: (0,020 – 10,0) mg/kg Atomic absorption spectrometry with amalgamation technique method PB-34/WR-PWR issue 1 of 01.06.2021
58 Soil Dry matter Range: (10,0 – 100) % Gravimetric method ISO 11465:1999
59 Soil Water content (calculated)
60 Soil pH Range: (2,0 – 12,0) Potentiometric method PN-EN ISO 10390:2022-09
61 Sewage sludge pH Range (2,0 – 14,0) Potentiometric method PN-EN 12176:2004
62 Sewage sludge Dry matter Range: (1,0 – 99,5) % Gravimetric method PN-EN 12880:2004
63 Aqueous extracts prepared at the Laboratory in Jelenia Góra from waste O): code 10 09 10, 19 01 12 Concentration/ content of anions Range: - chlorides (1,0 – 1000) mg/l (10 – 10000) mg/kg - sulphates (1,0 – 1000) mg/l (10 – 10000) mg/kg Ion chromatography method with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
64 Aqueous extracts prepared at the Laboratory in Jelenia Góra from waste O): code 10 09 10, 19 01 12 Total dissolved solids (TDS) Range: (20 – 10000) mg/l (200 – 100000) mg/kg Gravimetric method PN-EN 15216:2022-03
65 Aqueous extracts prepared at the Laboratory in Jelenia Góra from waste O): code 10 09 10, 19 01 12 Phenol index Range: (0,001 – 1,0) mg/l (0,01 – 10,0) mg/kg Flow analysis method (CFA) with spectrometric detection PN-EN ISO 14402:2004
66 Waste O): code 10 09 10, 19 01 12 Dry matter Range: (10,0 – 99) % Gravimetric method PN-EN 15934:2013-02 Method A
67 Water, wastewater Total suspended solids (TSS) Range: (5,0 – 6000) mg/l Gravimetric method PN-EN 872:2007+Ap.1:2007
68 Water, wastewater Biochemical oxygen demand - BOD ,BOD5 2+5 Range: (5,0 – 6000) mg/l O2 Electrochemical method PN-EN ISO 5815-1:2019-12
69 Water, wastewater Total suspended solids Range: (3,0 – 10000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
70 Water, wastewater Total dissolved solids (TDS) Range: (20 – 20000) mg/l Gravimetric method PN-EN 15216:2022-03
71 Water, wastewater Chloride concentration Range: (5,0 – 10000) mg/l Titrimetric method PN-ISO 9297:1994
72 Water, wastewater Ammonium nitrogen concentration Range: (0,01 – 778) mg/l Ammonium ion concentration Range: (0,01 – 1000) mg/l Spectrophotometric method PN-ISO 7150-1:2002
73 Water, wastewater Nitrate nitrogen concentration Range: (0,1 – 225) mg/l Nitrate concentration Range: (0,4 – 1000) mg/l Spectrophotometric method PN-82/C-04576.08
74 Water, wastewater Nitrite nitrogen concentration Range: (0,001 – 300) mg/l Nitrite concentration Range: (0,003 – 1000) mg/l Spectrophotometric method PN-EN 26777:1999
75 Water, wastewater Orthophosphate concentration Range: (0,010 – 1000) mg/l Spectrophotometric method PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010
76 Water, wastewater Total phosphorus concentration Range: (0,029 – 326) mg/l Spectrophotometric method PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010
77 Water, wastewater Total organic carbon (TOC) concentration Range: (0,5 – 1000 ) mg/l Infrared range spectrometry method (IR) PN-EN 1484:1999
78 Water, wastewater Anion concentrations Range: chlorides: (0,05 – 1000) mg/l nitrate nitrogen: (0,04 – 22,6) mg/l nitrates: (0,18 – 100) mg/l sulfates: (0,24 – 1000) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
79 Water, wastewater Metal concentrations Range: aluminium (0,010 – 1000) mg/l arsenic (0,005 – 1000) mg/l boron (0,010 – 1000) mg/l barium (0,001 – 1000) mg/l beryllium (0,0001 – 1000) mg/l cadmium (0,0005 – 1000) mg/l cobalt (0,002 – 1000) mg/l chromium (0,002 – 1000) mg/l copper (0,005 – 1000) mg/l iron (0,005 – 1000) mg/l manganese (0,001 – 1000) mg/l molybdenum (0,001 – 1000) mg/l nickel (0,0025 – 1000) mg/l lead (0,0025 – 1000) mg/l selenium (0,010 – 1000) mg/l silver (0,001 – 1000) mg/l titanium (0,001 – 1000) mg/l vanadium (0,001 – 1000) mg/l zinc (0,010 – 1000) mg/l sodium (0,05 – 1000) mg/l potassium (0,05 – 1000) mg/l calcium (0,10 – 1000) mg/l magnesium (0,01 – 1000) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885: 2009
80 Water, wastewater Metal concentrations Range: aluminium (0,0050 – 1000) mg/l arsenic (0,0010 – 20) mg/l boron (0,0050 – 1000) mg/l barium (0,0010 – 1000) mg/l beryllium (0,0010 – 20) mg/l cadmium (0,0010 – 1000) mg/l cobalt (0,0010 – 1000) mg/l chromium (0,0010 – 1000) mg/l copper (0,0010 – 1000) mg/l iron (0,0050 – 1000) mg/l manganese (0,0010 – 1000) mg/l molybdenum (0,0050 – 20) mg/l nickel (0,0010 – 1000) mg/l lead (0,0010 – 1000) mg/l selenium (0,0050 – 20) mg/l silver (0,00025 – 1000) mg/l titanium (0,0010 – 20) mg/l vanadium (0,0010 – 20) mg/l zinc (0,0050 – 1000) mg/l sodium (0,10 – 1000) mg/l potassium (0,10 – 1000) mg/l calcium (0,10 – 1000) mg/l magnesium (0,10 – 1000) mg/l thallium (0,0010 – 1000) mg/l tin (0,0010 – 20) mg/l antimony (0,0010 – 20) mg/l Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
81 Water, wastewater Ammonium nitrogen concentration Range: (0,078 – 778) mg/l N-NH4 (0,10 – 1000) mg/l NH4 Flow analysis (CFA) with spectrophotometric detection EN ISO 11732:2007
82 Water, wastewater Nitrite nitrogen concentration Range: N-NO (0,001 – 300) mg/l 2 NO (0,003 – 1000) mg/l 2 Flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
83 Water, wastewater Chemical oxygen demand - COD-Cr Range: (5 – 1000) mg/l O2 Spectrophotometric method PN-ISO 15705:2005
84 Water, wastewater Kjeldahl nitrogen concentration Range: (0,2 – 100) mg/l Spectrophotometric method PN-EN 25663:2001
85 Water, wastewater Mercury concentration Range: (0,01 – 40) g/l Atomic fluorescence spectrometry method (ASF) PN-EN ISO 17852:2009
86 Water, wastewater Total phosphorus concentration Range: (0,0050 – 1000) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
87 Water Biochemical oxygen demand - BOD , BOD5 2+5 Range: (3 – 6000) mg/l O2 Electrochemical method PN-EN ISO 5815-1:2019-12
88 Water Selenium concentration Range: (0,005 – 0,25) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885: 2009
89 Wastewater Biochemical oxygen demand - BOD5 Range: (3 – 6000) mg/l O2 Electrochemical method PN-EN ISO 5815-1:2019-12
90 Sewage sludge Dry residue / water content Range: (1,0 – 99) % Gravimetric method PN-EN 12880:2004
91 Sewage sludge Loss on ignition of dry matter (LOI) Range: (1,0 – 99) % Gravimetric method PN-EN 12879:2004
92 Sewage sludge pH Range: (2,0 – 12,0) Potentiometric method PN-EN 12176:2004
93 Sewage sludge Kjeldahl nitrogen content Range: (0,2 – 5,0) % Spectrophotometric method PB-02/WR-PJG issue 1 of 30.03.2021
94 Sewage sludge Ammonium nitrogen content Range: (0,04 – 1,2) % Spectrophotometric method PB-03/WR-PJG issue 1 of 30.03.2021
95 Sewage sludge Phosphorus content Range: (0,5 – 5,0) % Spectrophotometric method PB-04/WR-PJG issue 1 of 30.03.2021
96 Sewage sludge Metal content Range: lead (6,25 – 12500) mg/kg cadmium (0,125 – 6250) mg/kg nickel (2,5 – 6250) mg/kg zinc (5,0 – 31250) mg/kg copper (2,5 – 12500) mg/kg chromium (2,5 – 6250) mg/kg calcium (0,05 – 62,5) % magnesium (0,01 – 18,75) % Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 Method C
97 Soil Metal content Range: arsenic (1,25 – 6250) mg/kg barium (0,25 – 6250) mg/kg chromium (2,5 – 6250) mg/kg zinc (5,0 – 31250) mg/kg cadmium (0,125 – 6250) mg/kg cobalt (2,5 – 6250) mg/kg copper (2,5 – 12500) mg/kg nickel (2,5 – 6250) mg/kg lead (6,25 – 12500) mg/kg iron (1,25 – 31250) mg/kg manganese (0,25 – 31250) mg/kg vanadium (2,5 – 6250) mg/kg strontium (0,25 – 3125) mg/kg titanium (2,5 – 6250) mg/kg Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 Method C
98 Waste O): code 10 09 10, 19 01 12 Concentration/ content of metals Range: arsenic (0,005 – 100) mg/l (0,05 – 1000) mg/kg barium (0,001 – 100) mg/l (0,010 – 1000) mg/kg cadmium (0,0005 – 100) mg/l (0,005 – 1000) mg/kg chromium (0,002 – 100) mg/l (0,02 – 1000) mg/kg copper (0,005 – 100) mg/l (0,05 – 1000) mg/kg molybdenum (0,001 – 100) mg/l (0,01 – 1000) mg/kg nickel (0,0025 – 100) mg/l (0,025 – 1000) mg/kg lead (0,0025 – 100) mg/l (0,025 – 1000) mg/kg antimony (0,005 – 100) mg/l (0,05 – 1000) mg/kg selenium (0,005 – 100) mg/l (0,05 – 1000) mg/kg zinc (0,010 – 100) mg/l (0,10 – 1000) mg/kg Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 PN-EN 12457-4:2006
99 Waste O): code 10 09 10, 19 01 12 Concentration/ content of dissolved organic carbon Range: (0,5 – 1000) mg/l (5 – 10000) mg/kg Infrared spectrometry method (IR) PN-EN 1484:1999 PN-EN 12457-4:2006
100 Water, wastewater Ammonium nitrogen concentration Range: (3,0 – 1000) mg/l Ammonium ion concentration Range: (3,9 – 1290) mg/l Titrimetric method PN-ISO 5664:2002
101 Water, wastewater Ammonium nitrogen concentration Range: (0,025 – 8,0) mg/l Ammonium ion concentration Range: (0,032 – 10) mg/l Spectrophotometric method PN-ISO 7150-1:2002
102 Water, wastewater Kjeldahl nitrogen concentration Range: (0,5 – 3,0) mg/l Spectrophotometric method PN-EN 25663:2001
103 Water, wastewater Kjeldahl nitrogen concentration Range: (3,0 – 1000) mg/l Titrimetric method PN-EN 25663:2001
104 Water, wastewater Nitrite nitrogen concentration Range: (0,0025 – 20) mg/l Nitrite concentration Range: (0,008 – 66) mg/l Spectrophotometric method PN-EN 26777:1999
105 Water, wastewater Orthophosphate concentration Range: (0,031 – 123) mg/l Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010
106 Water, wastewater Total phosphorus concentration Range: (0,010 – 40) mg/l Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010
107 Water, wastewater Chemical oxygen demand - COD-Cr Range: (8 – 125) mg/l O2 Spectrophotometric method PN-ISO 15705:2005
108 Water, wastewater Biochemical oxygen demand - BOD BOD5, 2+5 Range: (3,0 – 6000) mg/l O2 Electrochemical method PN-EN ISO 5815-1:2019-12
109 Water, wastewater Biochemical oxygen demand - BOD BOD5, 2+5 Range: (0,5 – 6,0) mg/l O2 Electrochemical method PN-EN 1899-2:2002
110 Water, wastewater Rainwater Snowmelt water Total suspended solids (TSS) Range: (5,0 – 2000) mg/l Gravimetric method PN-EN 872:2007+ Ap1:2007

Reference standards (70)

EN ISO 11732:2007
ISO 10381-4:2007 PN ISO 10381-5:2009
ISO 11465:1999
No. 7
No. 8
PB-02/WR issue 1 of 01.06.2021
PB-02/WR-PJG issue 1 of 30.03.2021
PB-03/WR issue 1 of 01.06.2021
PB-03/WR-PJG issue 1 of 30.03.2021
PB-04/WR-PJG issue 1 of 30.03.2021
PB-05/WR issue 1 of 01.04.2021
PB-11/CLB issue 1 of 25.09.2023
PB-34/WR-PWR issue 1 of 01.06.2021
PN-77/C-04584
PN-82/C-04576.08
PN-86/C-04573/01
PN-EN 12176:2004
PN-EN 12619:2013-05
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 13649:2005
PN-EN 1484:1999
PN-EN 1484:1999 PN-EN 12457-4:2006
PN-EN 15216:2022-03
PN-EN 15681-2:2019-02
PN-EN 15934:2013-02 Method A
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 25813:1997
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+ Ap1:2007
PN-EN 872:2007+Ap.1:2007
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11732:2007
PN-EN ISO 11885: 2009
PN-EN ISO 11885:2009
PN-EN ISO 11885:2009 PN-EN 12457-4:2006
PN-EN ISO 11885:2009 PN-EN ISO 13346:2002 Method C
PN-EN ISO 13395:2001
PN-EN ISO 14402:2004
PN-EN ISO 14911:2002
PN-EN ISO 17294-2:2024-04
PN-EN ISO 17852:2009
PN-EN ISO 5667-11:2017-10 excluding cl. 5.2
PN-EN ISO 5667-13:2011
PN-EN ISO 5667-6:2016-12 PN-77/C-04584
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 + Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010
PN-EN ISO 9377-2:2003
PN-ISO 10396:2001
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 7150-1:2002
PN-ISO 9297:1994
PN-Z-04008-4:1999
PN-Z-04030-7:1994
…regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023
…regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630)
…regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140
…excluding clause F
…excluding point H (Journal of Laws 2011 No. 288
No. 3

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20075