🇵🇱 SIEĆ BADAWCZA ŁUKASIEWICZ - INSTYTUT ELEKTROTECHNIKI PL

PCA AB 022 • Warszawa, Poland • 113 methods

ConstructionMaterials & polymersWater & wastewaterElectronics & EMCAutomotive

SIEĆ BADAWCZA ŁUKASIEWICZ - INSTYTUT ELEKTROTECHNIKI is a laboratory accredited by PCA under number AB 022 (Warszawa, Poland). Its accreditation scope covers 113 test methods in the following areas: Construction, Materials & polymers, Water & wastewater, Electronics & EMC. Test objects include: Low-voltage electrical machinery and equipment, including lighting,…, Low-voltage electrical machines and equipment, including lighting a…, Electric lighting of rail vehicles in public transport systems, Electrotechnical products. Most frequently used techniques: Direct measurement method.

At a glance

  • Accreditation number: PCA AB 022
  • Methods in scope: 113
  • Types of test objects: 81
  • Techniques used: 1
  • City: Warszawa, Poland
Accreditation number
AB 022
Accreditation body
PCA
Address
LABORATORIUM BADAWCZE I WZORCUJĄCE URZĄDZEŃ ELEKTRYCZNYCH, ul. Pożaryskiego 28, 04-703 Warszawa
City
Warszawa, Poland

What this laboratory tests (81)

Analytical techniques used (1)

Laboratory locations

Certificate information

Issue date
08.09.2026
Issue no.
27

Accreditation scope — test methods (113)

No. Test object Methodology / Parameters Technique Reference document
Electrical Equipment Testing and Calibration Laboratory
1 Tungsten filament lamps for domestic and similar general lighting purposes Durability of marking, Protection against accidental contact in screw lampholders, Lamp cap temperature rise, Torsion resistance, Insulation resistance, Accessibility of accidentally live parts, Creepage distances, Surge impulse withstand, Durability, Interchangeability PN-EN 60432-1:2001 | PN-EN 60432-1:2001/A1:2006 | PN-EN 60432-1:2001/A2:2012
2 Halogen lamps for domestic and similar general lighting purposes Durability of marking, Protection against accidental contact in screw lampholders, Lamp cap temperature rise, Torsion resistance, Insulation resistance, Accessibility of accidentally live parts, Creepage distances, Safety at end of life, Interchangeability PN-EN 60432-2:2001 | PN-EN 60432-2:2001/A1:2007 | PN-EN 60432-2:2001/A2:2012
3 Halogen lamps (other than for vehicles) Durability of marking, Insulation distances, Linear dimensions, Safety at end of life PN-EN 60432-3:2013-06
4 Discharge lamps (excluding fluorescent lamps) Durability of marking, Linear dimensions, Insulation distances, Compatibility of cap-holder keys, Tensile and torsional strength, Accessibility of accidentally live parts, Insulation resistance, Electric strength, Resistance to heat, flame and ignition, Pulse height in lamps with internal ignition circuit PN-EN 62035:2015-05 | PN-EN 62035:2015-05/A1:2019-11
5 Self-ballasted lamps for general lighting services Durability of marking, Interchangeability, Protection against electric shock, Insulation resistance and electric strength of insulation, Torsion resistance, Cap temperature rise, Resistance to heat, flame and ignition, Fault conditions PN-EN 60968:2015-12
6 Double-capped fluorescent lamps Durability of marking, Correctness of construction and fixing, Linear dimensions, Insulation resistance, Electric strength, Accessibility of accidentally live parts, Resistance to heat and fire, Insulation distances, Lamp cap temperature rise, Minimum overall lamp length PN-EN 61195:2005 | PN-EN 61195:2005/A1:2013-06 | PN-EN 61195:2005/A2:2015-04
7 Single-capped fluorescent lamps Durability of marking, Correctness of construction and fixing, Linear dimensions, Keyed caps, Insulation resistance, Electric strength, Accessibility of accidentally live parts, Resistance to heat and fire, Insulation distance for caps, Lamp cap temperature rise, Fire and ignition resistance of radio interference suppression capacitors PN-EN 61199:2011 | PN-EN 61199:2011/A1:2013-06 | PN-EN 61199:2011/A2:2015-04
8 Luminaires Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN IEC 60598-1:2021-07 | PN-EN IEC 60598-1:2021-07/A11:2022-12
9 Fixed general purpose luminaires Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN IEC 60598-2-1:2021-09
10 Recessed luminaires Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN IEC 60598-2-2:2024-06
11 Road and street lighting luminaires Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-3:2006 | PN-EN 60598-2-3:2006/A1:2012
12 Portable general purpose luminaires Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-4:2018-06
13 Floodlighting projectors Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-5:2016-02
14 Portable garden luminaires Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-4:2018-06
15 Hand-held luminaires Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-8:2013-12
16 Photo and film luminaires (non-professional) Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-9:2002
17 Portable luminaires used by children Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-10:2005
18 Aquarium luminaires Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-11:2014-01 | PN-EN 60598-2-11:2014-01/A1:2023-03
19 Night lights Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-12:2013-12
20 Ground recessed luminaires Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-13:2007 | PN-EN 60598-2-13:2007/A1:2012 | PN-EN 60598-2-13:2007/A2:2017-02 | PN-EN 60598-2-13:2007/A11:2021-09 excluding the pressure resistance tests
21 Luminaires for stage lighting and television and film studios Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN IEC 60598-2-17:2018-05
22 Luminaires for swimming pools and similar applications Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN IEC 60598-2-18:2023-05
23 Air-handling luminaires Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-19:2002
24 Lighting chains Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-20:2015-07
25 Luminaires for emergency lighting Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN IEC 60598-2-22:2022-11
26 ELV lighting systems for filament lamps Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN IEC 60598-2-23:2021-06
27 Luminaires with limited surface temperatures Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-24:2014-02
28 Luminaires for use in clinical areas of hospitals and health care buildings Durability of marking, Linear dimensions, Mechanical strength, Mechanical stability, Continuity of protective connections, Resistance of protective connections, Protection against electric shock, Discharge of capacitors, Resistance to ingress of dust, solid objects and water, Insulation resistance and electric strength, Creepage distances and clearances, Endurance, Operating temperatures, Resistance to heat, fire and tracking, Correct construction of terminals, Spatial distribution of luminous intensity, Luminous flux, Change of luminous flux over time, Switching capability after failure of the normal supply, Decrease of luminous flux at high temperature, Battery charging current, Correct operation of the test device – simulation of normal supply failure PN-EN 60598-2-25:2000 | PN-EN 60598-2-25:2000/A1:2005
29 Equipment for lamps Durability of marking, Dimensions and construction of terminals, Continuity of protective connections, Resistance of protective connections, Protection against accidental contact with live parts, Moisture resistance and insulation, Electric strength, Thermal endurance of ballast windings, Protection against fire and electric shock under single fault conditions, Flammability of insulating materials, Construction of insulation, Operation of the device inhibiting or limiting the generation of ignition voltage pulses, Current in the lamp circuit, Disturbance voltage, Creepage distances and clearances, Durability of electrical and mechanical connections, Resistance to heat, fire and tracking, Temperature rises, Time to lamp ignition, Switching capability, Lamp current and luminous flux, Supply current, Lamp current waveform, Open-circuit output voltage, Output circuit current, Switching capability after failure of the normal supply, Operation of the charging device, Protection against excessive discharge, Operation of the indicator, Operation of the remote control, Resistance to reversed polarity, Resistance to high-voltage impulses, Protection against short circuit and overload, Operation with a defective lamp PN-EN 61347-1:2015-09 | PN-EN 61347-1:2015-09/A1:2021-06
30 Ignitors (other than glow starters) Durability of marking, Dimensions and construction of terminals, Continuity of protective connections, Resistance of protective connections, Protection against accidental contact with live parts, Moisture resistance and insulation, Electric strength, Thermal endurance of ballast windings, Protection against fire and electric shock under single fault conditions, Flammability of insulating materials, Construction of insulation, Operation of the device inhibiting or limiting the generation of ignition voltage pulses, Current in the lamp circuit, Disturbance voltage, Creepage distances and clearances, Durability of electrical and mechanical connections, Resistance to heat, fire and tracking, Temperature rises, Time to lamp ignition, Switching capability, Lamp current and luminous flux, Supply current, Lamp current waveform, Open-circuit output voltage, Output circuit current, Switching capability after failure of the normal supply, Operation of the charging device, Protection against excessive discharge, Operation of the indicator, Operation of the remote control, Resistance to reversed polarity, Resistance to high-voltage impulses, Protection against short circuit and overload, Operation with a defective lamp PN-EN 61347-2-1:2005 | PN-EN 61347-2-1:2005/A1:2007 | PN-EN 61347-2-1:2005/A2:2014-04
31 DC or AC supplied electronic step-down convertors for filament lamps Durability of marking, Dimensions and construction of terminals, Continuity of protective connections, Resistance of protective connections, Protection against accidental contact with live parts, Moisture resistance and insulation, Electric strength, Thermal endurance of ballast windings, Protection against fire and electric shock under single fault conditions, Flammability of insulating materials, Construction of insulation, Operation of the device inhibiting or limiting the generation of ignition voltage pulses, Current in the lamp circuit, Disturbance voltage, Creepage distances and clearances, Durability of electrical and mechanical connections, Resistance to heat, fire and tracking, Temperature rises, Time to lamp ignition, Switching capability, Lamp current and luminous flux, Supply current, Lamp current waveform, Open-circuit output voltage, Output circuit current, Switching capability after failure of the normal supply, Operation of the charging device, Protection against excessive discharge, Operation of the indicator, Operation of the remote control, Resistance to reversed polarity, Resistance to high-voltage impulses, Protection against short circuit and overload, Operation with a defective lamp PN-EN 61347-2-2:2012
32 AC supplied electronic ballasts for fluorescent lamps Durability of marking, Dimensions and construction of terminals, Continuity of protective connections, Resistance of protective connections, Protection against accidental contact with live parts, Moisture resistance and insulation, Electric strength, Thermal endurance of ballast windings, Protection against fire and electric shock under single fault conditions, Flammability of insulating materials, Construction of insulation, Operation of the device inhibiting or limiting the generation of ignition voltage pulses, Current in the lamp circuit, Disturbance voltage, Creepage distances and clearances, Durability of electrical and mechanical connections, Resistance to heat, fire and tracking, Temperature rises, Time to lamp ignition, Switching capability, Lamp current and luminous flux, Supply current, Lamp current waveform, Open-circuit output voltage, Output circuit current, Switching capability after failure of the normal supply, Operation of the charging device, Protection against excessive discharge, Operation of the indicator, Operation of the remote control, Resistance to reversed polarity, Resistance to high-voltage impulses, Protection against short circuit and overload, Operation with a defective lamp PN-EN 61347-2-3:2011
33 DC supplied electronic ballasts for general lighting, AC and/or DC supplied electronic control gear for fluorescent lamps Durability of marking, Dimensions and construction of terminals, Continuity of protective connections, Resistance of protective connections, Protection against accidental contact with live parts, Moisture resistance and insulation, Electric strength, Thermal endurance of ballast windings, Protection against fire and electric shock under single fault conditions, Flammability of insulating materials, Construction of insulation, Operation of the device inhibiting or limiting the generation of ignition voltage pulses, Current in the lamp circuit, Disturbance voltage, Creepage distances and clearances, Durability of electrical and mechanical connections, Resistance to heat, fire and tracking, Temperature rises, Time to lamp ignition, Switching capability, Lamp current and luminous flux, Supply current, Lamp current waveform, Open-circuit output voltage, Output circuit current, Switching capability after failure of the normal supply, Operation of the charging device, Protection against excessive discharge, Operation of the indicator, Operation of the remote control, Resistance to reversed polarity, Resistance to high-voltage impulses, Protection against short circuit and overload, Operation with a defective lamp PN-EN 61347-2-3:2011 | PN-EN 61347-2-3:2011/A1:2017-07
34 DC supplied electronic ballasts for emergency lighting Durability of marking, Dimensions and construction of terminals, Continuity of protective connections, Resistance of protective connections, Protection against accidental contact with live parts, Moisture resistance and insulation, Electric strength, Thermal endurance of ballast windings, Protection against fire and electric shock under single fault conditions, Flammability of insulating materials, Construction of insulation, Operation of the device inhibiting or limiting the generation of ignition voltage pulses, Current in the lamp circuit, Disturbance voltage, Creepage distances and clearances, Durability of electrical and mechanical connections, Resistance to heat, fire and tracking, Temperature rises, Time to lamp ignition, Switching capability, Lamp current and luminous flux, Supply current, Lamp current waveform, Open-circuit output voltage, Output circuit current, Switching capability after failure of the normal supply, Operation of the charging device, Protection against excessive discharge, Operation of the indicator, Operation of the remote control, Resistance to reversed polarity, Resistance to high-voltage impulses, Protection against short circuit and overload, Operation with a defective lamp PN-EN 61347-2-7:2012 | PN-EN 61347-2-7:2012/A1:2019-11 | PN-EN 61347-2-7:2012/A2:2022-11
35 Ballasts for fluorescent lamps Durability of marking, Dimensions and construction of terminals, Continuity of protective connections, Resistance of protective connections, Protection against accidental contact with live parts, Moisture resistance and insulation, Electric strength, Thermal endurance of ballast windings, Protection against fire and electric shock under single fault conditions, Flammability of insulating materials, Construction of insulation, Operation of the device inhibiting or limiting the generation of ignition voltage pulses, Current in the lamp circuit, Disturbance voltage, Creepage distances and clearances, Durability of electrical and mechanical connections, Resistance to heat, fire and tracking, Temperature rises, Time to lamp ignition, Switching capability, Lamp current and luminous flux, Supply current, Lamp current waveform, Open-circuit output voltage, Output circuit current, Switching capability after failure of the normal supply, Operation of the charging device, Protection against excessive discharge, Operation of the indicator, Operation of the remote control, Resistance to reversed polarity, Resistance to high-voltage impulses, Protection against short circuit and overload, Operation with a defective lamp PN-EN 61347-2-8:2003 | PN-EN 61347-2-8:2003/A1:2007
36 Ballasts for discharge lamps (excluding fluorescent lamps) Durability of marking, Dimensions and construction of terminals, Continuity of protective connections, Resistance of protective connections, Protection against accidental contact with live parts, Moisture resistance and insulation, Electric strength, Thermal endurance of ballast windings, Protection against fire and electric shock under single fault conditions, Flammability of insulating materials, Construction of insulation, Operation of the device inhibiting or limiting the generation of ignition voltage pulses, Current in the lamp circuit, Disturbance voltage, Creepage distances and clearances, Durability of electrical and mechanical connections, Resistance to heat, fire and tracking, Temperature rises, Time to lamp ignition, Switching capability, Lamp current and luminous flux, Supply current, Lamp current waveform, Open-circuit output voltage, Output circuit current, Switching capability after failure of the normal supply, Operation of the charging device, Protection against excessive discharge, Operation of the indicator, Operation of the remote control, Resistance to reversed polarity, Resistance to high-voltage impulses, Protection against short circuit and overload, Operation with a defective lamp PN-EN 61347-2-9:2013-06
37 Electronic invertors and convertors for high-frequency operation of cold-start tubular discharge lamps (neon tubes) Durability of marking, Dimensions and construction of terminals, Continuity of protective connections, Resistance of protective connections, Protection against accidental contact with live parts, Moisture resistance and insulation, Electric strength, Thermal endurance of ballast windings, Protection against fire and electric shock under single fault conditions, Flammability of insulating materials, Construction of insulation, Operation of the device inhibiting or limiting the generation of ignition voltage pulses, Current in the lamp circuit, Disturbance voltage, Creepage distances and clearances, Durability of electrical and mechanical connections, Resistance to heat, fire and tracking, Temperature rises, Time to lamp ignition, Switching capability, Lamp current and luminous flux, Supply current, Lamp current waveform, Open-circuit output voltage, Output circuit current, Switching capability after failure of the normal supply, Operation of the charging device, Protection against excessive discharge, Operation of the indicator, Operation of the remote control, Resistance to reversed polarity, Resistance to high-voltage impulses, Protection against short circuit and overload, Operation with a defective lamp PN-EN 61347-2-10:2002 | PN-EN 61347-2-10:2002/A1:2009
38 Miscellaneous electronic circuits used with luminaires Durability of marking, Dimensions and construction of terminals, Continuity of protective connections, Resistance of protective connections, Protection against accidental contact with live parts, Moisture resistance and insulation, Electric strength, Thermal endurance of ballast windings, Protection against fire and electric shock under single fault conditions, Flammability of insulating materials, Construction of insulation, Operation of the device inhibiting or limiting the generation of ignition voltage pulses, Current in the lamp circuit, Disturbance voltage, Creepage distances and clearances, Durability of electrical and mechanical connections, Resistance to heat, fire and tracking, Temperature rises, Time to lamp ignition, Switching capability, Lamp current and luminous flux, Supply current, Lamp current waveform, Open-circuit output voltage, Output circuit current, Switching capability after failure of the normal supply, Operation of the charging device, Protection against excessive discharge, Operation of the indicator, Operation of the remote control, Resistance to reversed polarity, Resistance to high-voltage impulses, Protection against short circuit and overload, Operation with a defective lamp PN-EN 61347-2-11:2005 | PN-EN 61347-2-11:2005/A1:2019-09
39 AC supplied electronic ballasts for discharge lamps (excluding fluorescent lamps) Durability of marking, Dimensions and construction of terminals, Continuity of protective connections, Resistance of protective connections, Protection against accidental contact with live parts, Moisture resistance and insulation, Electric strength, Thermal endurance of ballast windings, Protection against fire and electric shock under single fault conditions, Flammability of insulating materials, Construction of insulation, Operation of the device inhibiting or limiting the generation of ignition voltage pulses, Current in the lamp circuit, Disturbance voltage, Creepage distances and clearances, Durability of electrical and mechanical connections, Resistance to heat, fire and tracking, Temperature rises, Time to lamp ignition, Switching capability, Lamp current and luminous flux, Supply current, Lamp current waveform, Open-circuit output voltage, Output circuit current, Switching capability after failure of the normal supply, Operation of the charging device, Protection against excessive discharge, Operation of the indicator, Operation of the remote control, Resistance to reversed polarity, Resistance to high-voltage impulses, Protection against short circuit and overload, Operation with a defective lamp PN-EN 61347-2-12:2006 | PN-EN 61347-2-12:2006/A1:2011
40 DC or AC supplied electronic controlgear for LED modules Durability of marking, Dimensions and construction of terminals, Continuity of protective connections, Resistance of protective connections, Protection against accidental contact with live parts, Moisture resistance and insulation, Electric strength, Thermal endurance of ballast windings, Protection against fire and electric shock under single fault conditions, Flammability of insulating materials, Construction of insulation, Operation of the device inhibiting or limiting the generation of ignition voltage pulses, Current in the lamp circuit, Disturbance voltage, Creepage distances and clearances, Durability of electrical and mechanical connections, Resistance to heat, fire and tracking, Temperature rises, Time to lamp ignition, Switching capability, Lamp current and luminous flux, Supply current, Lamp current waveform, Open-circuit output voltage, Output circuit current, Switching capability after failure of the normal supply, Operation of the charging device, Protection against excessive discharge, Operation of the indicator, Operation of the remote control, Resistance to reversed polarity, Resistance to high-voltage impulses, Protection against short circuit and overload, Operation with a defective lamp PN-EN 61347-2-13:2015-04 | PN-EN 61347-2-13:2015-04/A1:2017-07
41 Cable reels for household and similar purposes Durability of marking, Linear dimensions, Protection against electric shock, Continuity of protective connections, Resistance of protective connections, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Electric current, Power input, Power factor, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Resistance to ageing, harmful ingress of water and moisture, Insulation resistance and electric strength, Temperature rises, Flexing of flexible cords, Resistance to elevated temperature, Durability of electrical and mechanical connections, Insulation distances, Resistance to heat, fire and tracking PN-EN 61242:2001 | PN-EN 61242:2001/A1:2010 | PN-EN 61242:2001/A2:2016-03 | PN-EN 61242:2001/A13:2017-05
42 Socket-outlets and plugs for household and similar use Durability of marking, Linear dimensions, Protection against electric shock, Continuity of protective connections, Resistance of protective connections, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Electric current, Power input, Power factor, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Resistance to ageing, harmful ingress of water and moisture, Insulation resistance and electric strength, Temperature rises, Flexing of flexible cords, Resistance to elevated temperature, Durability of electrical and mechanical connections, Insulation distances, Resistance to heat, fire and tracking PN-IEC 60884-1:2024-04 | PN-E-53100:2022-05 | PN-E-93201:2021-05 | PN-E-93202:1997 | PN-E-93202:1997/Az:2004
43 Socket-outlets for appliances Durability of marking, Linear dimensions, Protection against electric shock, Continuity of protective connections, Resistance of protective connections, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Electric current, Power input, Power factor, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Resistance to ageing, harmful ingress of water and moisture, Insulation resistance and electric strength, Temperature rises, Flexing of flexible cords, Resistance to elevated temperature, Durability of electrical and mechanical connections, Insulation distances, Resistance to heat, fire and tracking PN-IEC 60884-2-2:2012
44 Switched socket-outlets without interlock for fixed installations Durability of marking, Linear dimensions, Protection against electric shock, Continuity of protective connections, Resistance of protective connections, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Electric current, Power input, Power factor, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Resistance to ageing, harmful ingress of water and moisture, Insulation resistance and electric strength, Temperature rises, Flexing of flexible cords, Resistance to elevated temperature, Durability of electrical and mechanical connections, Insulation distances, Resistance to heat, fire and tracking PN-IEC 60884-2-3:2012
45 Multi-way plug adaptors Durability of marking, Linear dimensions, Protection against electric shock, Continuity of protective connections, Resistance of protective connections, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Electric current, Power input, Power factor, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Resistance to ageing, harmful ingress of water and moisture, Insulation resistance and electric strength, Temperature rises, Flexing of flexible cords, Resistance to elevated temperature, Durability of electrical and mechanical connections, Insulation distances, Resistance to heat, fire and tracking PN-IEC 60884-2-5:2021:03
46 Electric toys Power input, Heating and operation under abnormal conditions, Electric strength, Moisture resistance, Mechanical strength, Dimensions and construction of terminals, Electric voltage, Electric current, Type of insulating materials, Construction of insulation, Components – tested characteristics: see the relevant product standards, Durability of electrical and mechanical connections, Insulation distances, Resistance to heat and fire PN-EN IEC 62115:2020-04 | PN-EN IEC 62115:2020-04/A11:2020-07
47 Variable message road information signs Response to voltage dips and mains frequency changes, Resistance to temporary overvoltage, Electrical safety, Emission of electromagnetic disturbances, Immunity to electromagnetic disturbances, Resistance to mechanical shocks, Resistance to water ingress, Resistance to ingress of solid objects and dust, Resistance to cold, Resistance to dry heat, Resistance to damp heat, cyclic, Resistance to temperature changes PN-EN 12966+A1:2019-02
48 Train head and tail signal lamp Luminous intensity, Colour, Kcolour factor (calculated) CIE Publication 15:2004 | PN-EN 13032-1+A1:2012 | PN-EN 15153+A1:2016-12 | PN-EN 15153-1:2020-06
49 Electrical appliances for household and similar use Protection against access to live parts, Starting of motor-operated appliances, Power input and current, Temperature rises, Surge overvoltage, Moisture resistance, Leakage current and electric strength, Overload protection of transformers and associated circuits, Endurance, Protection against fire and electric shock under abnormal operation, Stability and mechanical hazards, Mechanical strength, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Durability of electrical and mechanical connections, Continuity of protective connections, Resistance of protective connections, Supply connection, Terminals for external conductors, Dimensions and mechanical durability of mechanical and electrical connections, Creepage distances, clearances and distances through insulation, Resistance to high temperature, glow and tracking, Resistance to corrosion, Absolute value of UV and VIS irradiance, Effective irradiance weighted according to any spectral sensitivity characteristic in the above range, Measurement of electromagnetic field exposure PN-EN IEC 60335-1:2024-04
50 Appliances for skin exposure to infrared and ultraviolet radiation Protection against access to live parts, Starting of motor-operated appliances, Power input and current, Temperature rises, Surge overvoltage, Moisture resistance, Leakage current and electric strength, Overload protection of transformers and associated circuits, Endurance, Protection against fire and electric shock under abnormal operation, Stability and mechanical hazards, Mechanical strength, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Durability of electrical and mechanical connections, Continuity of protective connections, Resistance of protective connections, Supply connection, Terminals for external conductors, Dimensions and mechanical durability of mechanical and electrical connections, Creepage distances, clearances and distances through insulation, Resistance to high temperature, glow and tracking, Resistance to corrosion, Absolute value of UV and VIS irradiance, Effective irradiance weighted according to any spectral sensitivity characteristic in the above range, Measurement of electromagnetic field exposure PN-EN 60335-2-27:2014-02 | PN-EN 60335-2-27:2014-02/A1:2020-10 | PN-EN 60335-2-27:2014-02/A2:2020-08
51 Battery chargers Protection against access to live parts, Starting of motor-operated appliances, Power input and current, Temperature rises, Surge overvoltage, Moisture resistance, Leakage current and electric strength, Overload protection of transformers and associated circuits, Endurance, Protection against fire and electric shock under abnormal operation, Stability and mechanical hazards, Mechanical strength, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Durability of electrical and mechanical connections, Continuity of protective connections, Resistance of protective connections, Supply connection, Terminals for external conductors, Dimensions and mechanical durability of mechanical and electrical connections, Creepage distances, clearances and distances through insulation, Resistance to high temperature, glow and tracking, Resistance to corrosion, Absolute value of UV and VIS irradiance, Effective irradiance weighted according to any spectral sensitivity characteristic in the above range, Measurement of electromagnetic field exposure PN-EN 60335-2-29:2022-05 | PN-EN 60335-2-29:2022-05/A1:2022-06
52 Insect-killing devices Protection against access to live parts, Starting of motor-operated appliances, Power input and current, Temperature rises, Surge overvoltage, Moisture resistance, Leakage current and electric strength, Overload protection of transformers and associated circuits, Endurance, Protection against fire and electric shock under abnormal operation, Stability and mechanical hazards, Mechanical strength, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Durability of electrical and mechanical connections, Continuity of protective connections, Resistance of protective connections, Supply connection, Terminals for external conductors, Dimensions and mechanical durability of mechanical and electrical connections, Creepage distances, clearances and distances through insulation, Resistance to high temperature, glow and tracking, Resistance to corrosion, Absolute value of UV and VIS irradiance, Effective irradiance weighted according to any spectral sensitivity characteristic in the above range, Measurement of electromagnetic field exposure PN-EN 60335-2-59:2007 | PN-EN 60335-2-59:2007/A2:2010 | PN-EN 60335-2-59:2007/A11:2018-12
53 Kitchen machines Protection against access to live parts, Starting of motor-operated appliances, Power input and current, Temperature rises, Surge overvoltage, Moisture resistance, Leakage current and electric strength, Overload protection of transformers and associated circuits, Endurance, Protection against fire and electric shock under abnormal operation, Stability and mechanical hazards, Mechanical strength, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Durability of electrical and mechanical connections, Continuity of protective connections, Resistance of protective connections, Supply connection, Terminals for external conductors, Dimensions and mechanical durability of mechanical and electrical connections, Creepage distances, clearances and distances through insulation, Resistance to high temperature, glow and tracking, Resistance to corrosion, Absolute value of UV and VIS irradiance, Effective irradiance weighted according to any spectral sensitivity characteristic in the above range, Measurement of electromagnetic field exposure PN-EN IEC 60335-2-14:2024-03 | PN-EN IEC 60335-2-14:2024-03/A1:2024-06
54 Liquid heating appliances Protection against access to live parts, Starting of motor-operated appliances, Power input and current, Temperature rises, Surge overvoltage, Moisture resistance, Leakage current and electric strength, Overload protection of transformers and associated circuits, Endurance, Protection against fire and electric shock under abnormal operation, Stability and mechanical hazards, Mechanical strength, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Durability of electrical and mechanical connections, Continuity of protective connections, Resistance of protective connections, Supply connection, Terminals for external conductors, Dimensions and mechanical durability of mechanical and electrical connections, Creepage distances, clearances and distances through insulation, Resistance to high temperature, glow and tracking, Resistance to corrosion, Absolute value of UV and VIS irradiance, Effective irradiance weighted according to any spectral sensitivity characteristic in the above range, Measurement of electromagnetic field exposure PN-EN 60335-2-15:2016-04 | PN-EN 60335-2-15:2016-04/A11:2018-10 | PN-EN 60335-2-15:2016-04/A1:2021-11 | PN-EN 60335-2-15:2016-04/A2:2021-12 | PN-EN 60335-2-15:2016-04/A12:2022-03
55 Range hoods and other cooking fume extractors Protection against access to live parts, Starting of motor-operated appliances, Power input and current, Temperature rises, Surge overvoltage, Moisture resistance, Leakage current and electric strength, Overload protection of transformers and associated circuits, Endurance, Protection against fire and electric shock under abnormal operation, Stability and mechanical hazards, Mechanical strength, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Durability of electrical and mechanical connections, Continuity of protective connections, Resistance of protective connections, Supply connection, Terminals for external conductors, Dimensions and mechanical durability of mechanical and electrical connections, Creepage distances, clearances and distances through insulation, Resistance to high temperature, glow and tracking, Resistance to corrosion, Absolute value of UV and VIS irradiance, Effective irradiance weighted according to any spectral sensitivity characteristic in the above range, Measurement of electromagnetic field exposure PN-EN 60335-2-31:2015-02 | PN-EN 60335-2-31:2015-02/A1:2023-09 | PN-EN 60335-2-31:2015-02/A2:2023-09 | PN-EN 60335-2-31:2015-02/A11:2023-10
56 Commercial refrigerating appliances with an incorporated or remote condensing unit or compressor Protection against access to live parts, Starting of motor-operated appliances, Power input and current, Temperature rises, Surge overvoltage, Moisture resistance, Leakage current and electric strength, Overload protection of transformers and associated circuits, Endurance, Protection against fire and electric shock under abnormal operation, Stability and mechanical hazards, Mechanical strength, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Durability of electrical and mechanical connections, Continuity of protective connections, Resistance of protective connections, Supply connection, Terminals for external conductors, Dimensions and mechanical durability of mechanical and electrical connections, Creepage distances, clearances and distances through insulation, Resistance to high temperature, glow and tracking, Resistance to corrosion, Absolute value of UV and VIS irradiance, Effective irradiance weighted according to any spectral sensitivity characteristic in the above range, Measurement of electromagnetic field exposure PN-EN IEC 60335-2-89:2022-12 | PN-EN IEC 60335-2-89:2022-12/A11:2023-04
57 Amusement machines and personal service machines Protection against access to live parts, Starting of motor-operated appliances, Power input and current, Temperature rises, Surge overvoltage, Moisture resistance, Leakage current and electric strength, Overload protection of transformers and associated circuits, Endurance, Protection against fire and electric shock under abnormal operation, Stability and mechanical hazards, Mechanical strength, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Type of insulating materials, Construction of insulation, Components – characteristics tested according to the relevant product standards, Durability of electrical and mechanical connections, Continuity of protective connections, Resistance of protective connections, Supply connection, Terminals for external conductors, Dimensions and mechanical durability of mechanical and electrical connections, Creepage distances, clearances and distances through insulation, Resistance to high temperature, glow and tracking, Resistance to corrosion, Absolute value of UV and VIS irradiance, Effective irradiance weighted according to any spectral sensitivity characteristic in the above range, Measurement of electromagnetic field exposure PN-EN IEC 60335-2-82:2022-08
58 Medical electrical equipment Protection against access to live parts, Power input and current, Temperature rises, Surge overvoltage, Moisture resistance, Leakage current and electric strength, Overload protection of transformers and associated circuits, Endurance, Protection against fire and electric shock under abnormal operation, Stability and protection against mechanical hazards, Mechanical strength, Dimensions and construction of terminals, Mechanical strength, Electric voltage, Type of insulating materials, Construction of insulation, Components - characteristics tested according to the relevant product standards, Durability of electrical and mechanical connections, Continuity of protective connections, Resistance of protective connections, Supply connection, Terminals for external conductors, Dimensions and mechanical durability of mechanical and electrical connections, Creepage distances, clearances and distances through insulation, Resistance to high temperature, glow and tracking, Resistance to corrosion, Optical radiation power, Irradiance, Radiance in the range (250-830) nm, Illuminance, Luminance, Luminous intensity, General colour rendering index, Correlated colour temperature PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 13032-1+A1:2012 CIE Publication 13.3:1995 CIE Publication 15:2004 CIE Publication 084:1989 CIE Publication 63:1984
59 Incandescent lamps Torsional strength, Lamp voltage, current and active power under steady-state conditions, Luminous flux maintenance factor, Cap temperature rise, Durability of marking, Bulb dimensions, Initial power, Initial luminous flux, Luminous flux stability, Endurance, Linear dimensions of lamps, Linear dimensions of caps and bases, Protection against accidental contact, Access to accidentally live parts, Maximum power, Temperature of the pinch, bulb and contact tip of the rim, Chromaticity, Correlated colour temperature, Colour rendering index PN-EN 60064:2002 | PN-EN 60064:2002/A2:2003 | PN-EN 60064:2002/A3:2006 | PN-EN 60064:2002/A4:2007 | PN-EN 60064:2002/A5:2010 | PN-EN 60064:2002/A11:2008 | PN-EN 13032-1+A1:2012 CIE Publication 13.3:1995 CIE Publication 15:2004 CIE Publication 084:1989 CIE Publication 63:1984
60 Halogen lamps Torsional strength, Lamp voltage, current and active power under steady-state conditions, Luminous flux maintenance factor, Cap temperature rise, Durability of marking, Bulb dimensions, Initial power, Initial luminous flux, Luminous flux stability, Endurance, Linear dimensions of lamps, Linear dimensions of caps and bases, Protection against accidental contact, Access to accidentally live parts, Maximum power, Temperature of the pinch, bulb and contact tip of the rim, Chromaticity, Correlated colour temperature, Colour rendering index PN-EN 60357:2003 | PN-EN 60357:2003/A1:2008 | PN-EN 60357:2003/A2:2009 | PN-EN 60357:2003/A3:2011 | PN-EN 60357:2003/A11:2016-12 | PN-EN 13032-1+A1:2012 CIE Publication 13.3:1995 CIE Publication 15:20 CIE Publication 084:1989 CIE Publication 63:1984
61 Sodium vapour lamps Durability of lamp marking, Lamp dimensions, Linear dimensions of caps, Protection against accidental contact, Access to accidentally live parts, Peak value of the ignition pulse voltage, Lamp voltage, current and active power under steady-state conditions, Luminous flux, Preheating current, Current crest factor, Cap temperature rise, Resistance to rectifying effect, Chromaticity, Colour rendering index, Correlated colour temperature PN-EN 60662:2012 | PN-EN 60662:2012 /A11:2019-11 | PN-EN 13032-1+A1:2012 CIE Publication 13.3:1995 CIE Publication 15:2004 CIE Publication 084:1989 CIE Publication 63:1984
62 Metal halide lamps Durability of lamp marking, Lamp dimensions, Linear dimensions of caps, Protection against accidental contact, Access to accidentally live parts, Peak value of the ignition pulse voltage, Lamp voltage, current and active power under steady-state conditions, Luminous flux, Preheating current, Current crest factor, Cap temperature rise, Resistance to rectifying effect, Chromaticity, Colour rendering index, Correlated colour temperature PN-EN 61167:2019-01 | PN-EN 61167:2019-01/A1:2019-03 | PN-EN 13032-1+A1:2012 CIE Publication 13.3:1995 CIE Publication 15:2004 CIE Publication 084:1989 CIE Publication 63:1984
63 Double-capped fluorescent lamps Linear dimensions of caps, Linear dimensions of lamps, Lamp voltage, current and active power and cathode resistance under steady-state conditions, Luminous flux, Chromaticity, Colour rendering index, Correlated colour temperature, Luminous flux maintenance factor, Durability of marking, Cap temperature rise, Suppression of radio interference PN-EN 60081:2002 | PN-EN 60081:2002/A2:2005 | PN-EN 60081:2002/A3:2006 | PN-EN 60081:2002/A4:2010 | PN-EN 60081:2002/A5:2014-02 | PN-EN 60081:2002/A6:2018-02 | PN-EN 60081:2002/A11:2018-10 | PN-EN 13032-1+A1:2012 CIE Publication 13.3:1995 CIE Publication 15:2004 CIE Publication 084:1989 CIE Publication 63:1984
64 Single-capped fluorescent lamps Linear dimensions of caps, Linear dimensions of lamps, Lamp voltage, current and active power and cathode resistance under steady-state conditions, Luminous flux, Chromaticity, Colour rendering index, Correlated colour temperature, Luminous flux maintenance factor, Durability of marking, Cap temperature rise, Suppression of radio interference PN-EN 60901:2002 | PN-EN 60901:2002/A3:2005 | PN-EN 60901:2002/A4:2008 | PN-EN 60901:2002/A5:2012 | PN-EN 60901:2002/A6:2018-02 | PN-EN 13032-1+A1:2012 CIE Publication 13.3:1995 CIE Publication 15:2004 CIE Publication 084:1989 CIE Publication 63:1984
65 Self-ballasted lamps Linear dimensions of caps, Linear dimensions of lamps, Lamp voltage, current and active power and cathode resistance under steady-state conditions, Luminous flux, Chromaticity, Colour rendering index, Correlated colour temperature, Luminous flux maintenance factor, Durability of marking, Cap temperature rise, Suppression of radio interference PN-EN 60969:2002 | PN-EN 13032-1+A1:2012 CIE Publication 13.3:1995 CIE Publication 15:2004 CIE Publication 084:1989 CIE Publication 63:1984
66 Equipment for lamps Durability of marking, Output voltage and current, Power input, Power factor, Supply current, Lamp current and luminous flux, Abnormal operation, Functional characteristics, Radio interference suppression, Protection against magnetic influences, Durability PN-EN 60921:2005 | PN-EN 60921:2005/A1:2006 | PN-EN 60923:2006 | PN-EN 60923:2006/A1:2006 | PN-EN 61347-2-3:2011 | PN-EN 61347-2-3:2011/A1:2017-07 | PN-EN 60927:2007 | PN-EN 60927:2007/A1:2014-04 | PN-EN 60929:2011 | PN-EN 60929:2011/A1:2016-05 | PN-EN 61047:2005 | PN-EN 13032-1+A1:2012 CIE Publication 13.3:1995 CIE Publication 15:2004 CIE Publication 084:1989
67 Luminaires and light sources with a maximum linear dimension of the luminous surface of 1.2 m and a maximum current consumption up to 20 A and weight up to 30 kG. Luminous intensity distribution PN-EN 13032-1+A1:2012 | PN-EN 13032-2:2018-02 | PN-EN 13032-3:2022-04 | PN-EN IEC 60598-2-22:2022-11 | PN-EN 60079-35-2:2012 | PN-EN 12966+A1:2019-02
68 Mirror and lens floodlights with a focal length of up to 0.25 m and a body diameter of up to 1 m. Luminous intensity distribution PN-EN 13032-1+A1:2012 | PN-EN 13032-2:2018-02 | PN-EN 13032-3:2022-04 CIE Publication No. 43
69 Luminaires with a maximum linear dimension of the luminous surface of 1.2 m and a maximum current consumption up to 20 A and weight up to 30 kG. Luminous efficacy PN-EN IEC 60598-2-22:2022-11 | PN-EN 13032-1+A1:2012 | PN-EN 13032-2:2018-02 | PN-EN 13032-3:2022-04
70 Mirror and lens floodlights with a focal length of up to 0.25 m and a body diameter of up to 1 m. Luminous efficacy CIE Publication No. 43 | PN-EN 13032-1+A1:2012 | PN-EN 13032-2:2018-02 | PN-EN 13032-3:2022-04
71 Local lighting luminaires Illuminance (0-500) klx PN-EN 13032-1+A1:2012 | PN-EN 13032-2:2018-02 | PN-EN 13032-3:2022-04 | PN-EN 60079-35-2:2012
72 Rooms and circulation routes of buildings Illuminance (0-500) klx PN-EN 1838:2013-11 | PN-EN 12464-1:2022-01 | PN-EN 12464-2:2014-05
73 Electric lighting of rail vehicles in public transport systems Illuminance (0-500) klx PN-EN 13272-1:2020-03 | PN-EN 13272-2:2020-03
74 Emergency luminaires Luminance (0-999900) cd/m2 PN-EN IEC 60598-2-22:2022-11
75 Electric lighting of rail vehicles in public transport systems Luminance (0-999900) cd/m2 PN-EN 13272-1:2020-03 | PN-EN 13272-2:2020-03
76 Rooms and circulation routes of buildings Luminance (0-999900) cd/m2 PN-EN 1838:2013-11 | PN-EN 12464-1:2022-01 | PN-EN 12464-2:2014-05
77 Luminous surfaces, light sources Luminance (0-999900) cd/m2 PN-EN 12966+A1:2019-02 | PN-EN 60335-2-27:2014-02 | PN-EN 25580:1997 | PN-EN ISO 5580:2024-06
78 Rooms and circulation routes of buildings Illuminance uniformity PN-EN 1837:2021-05 | PN-EN 1838:2013-11 | PN-EN 12464-1:2022-01 | PN-EN 12464-2:2014-05
79 Electric lighting of rail vehicles in public transport systems Illuminance uniformity PN-EN 13272-1:2020-03 | PN-EN 13272-2:2020-03
80 Rooms and circulation routes of buildings Chromaticity (0-1) PN-EN 1837:2021-05 | PN-EN 1838:2013-11 | PN-EN 12464-1:2022-01 | PN-EN 12464-2:2014-05 CIE Publication 15:2004
81 Electric lighting of rail vehicles in public transport systems Chromaticity (0-1) PN-EN 13272-1:2020-03 | PN-EN 13272-2:2020-03 CIE Publication 15:2004
82 Luminous surfaces, light sources Chromaticity (0-1) PN-EN 12966+A1:2019-02 CIE Publication 15:2004
83 Luminaires with a max. linear dimension of the luminous surface of 1.2 m and a maximum current consumption up to 20 A and weight up to 30 kG. Overall luminance (0-999900) cd/m2 PN-EN 13032-1+A1:2012 | PN-EN 13032-2:2018-02 | PN-EN 13032-3:2022-04
84 Luminaires Geometric angle of protection, C0-C360°, Y0-90° PN-EN IEC 60598-1:2021-07 | PN-EN IEC 60598-1:2021-07/A11:2022-12
85 Signalling and emergency luminaires and special devices and their optical elements; light sources supplied with direct current of max. 20 A and voltage of max. 100 V or supplied with alternating current of max. 20 A. Spectral parameters in the VIS and UV range (200-800) nm CIE Publication 15:2004 CIE Publication 13.3:1995 CIE Publication 63:1984 | PN-EN 60335-2-27:2014-02 | PN-EN 60335-2-59:2007 | PN-EN 60335-2-59:2007/A2:2010 | PN-EN 60335-2-59:2007/A11:2018-12 | PN-EN IEC 60598-2-22:2022-11
86 Incandescent and discharge light sources with a luminous flux from 10 lm to 500000 lm and a power up to 5 kW, supplied with direct or alternating voltage, with a current up to 20 A and a maximum linear dimension up to 2 m. Luminous flux (0-50000) lm CIE Publication 084:1989 | PN-EN 60901:2002 | PN-EN 60901:2002/A3:2005 | PN-EN 60901:2002/A4:2008 | PN-EN 60901:2002/A5:2012 | PN-EN 60901:2002/A6:2018-02 | PN-EN 60064:2002 | PN-EN 60064:2002/A2:2003 | PN-EN 60064:2002/A3:2006 | PN-EN 60064:2002/A4:2007 | PN-EN 60064:2002/A11:2008 | PN-EN 60064:2002/A5:2010 | PN-EN 60969:2002 | PN-EN 60188:2004 | PN-EN 60188:2004/A11:2019-09
87 Emergency luminaires Luminous flux (0-50000) lm PN-EN IEC 60598-2-22:2022-11 | PN-EN 13032-1+A1:2012 CIE Publication 084:1989
88 Projection and special lamps, linear fluorescent lamps up to 40 W with a luminous intensity from 1cd to 50000 cd supplied with direct or alternating voltage, with a current not exceeding 20 A. Luminous intensity (0-500000) cd PN-EN 12966+A1:2019-02 | PN-EN 13032-1+A1:2012
89 DC and AC electronic ballasts Ballast lumen factor PN-EN 61347-2-7:2012 | PN-EN 61347-2-7:2012 /A1:2019-11 | PN-EN 61347-2-7:2012/A2:2022-11 | PN-EN 61347-2-3:2011 | PN-EN 61347-2-3:2011/A1:2017-07 | PN-EN 60929:2011 | PN-EN 60929:2011/A1:2016-05 | PN-EN 13032-1+A1:2012 CIE Publication 13.3:1995 CIE Publication 15:2004 CIE Publication 084:1989
90 Low-voltage electrical machines and equipment Sound power level determined from sound pressure level measurements
Range (16,5-100) dB
Direct measurement method PN-EN ISO 1680:2014-02 | PN-EN ISO 3744:2011 excluding, cl. 8.3. | PN-EN ISO 3743-1:2011 | PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/AP1:2017-09 | PN-EN ISO 3747:2011 | PN-EN 62271-202:2014-12 | PN-EN 62271-202:2014 -12/ AC1:2015-07 | PN-EN 60076-10:2017-01 | IEC 60076-10:2016
91 Computer and office equipment, hand-held, table-mounted or floor-standing at a distance from the wall greater than 1,5 m (except typewriters, teleprinters and keyboards) Sound power level determined from sound pressure level measurements
Range (16,5-100) dB
Direct measurement method PN-EN ISO 9295:2015-09 | PN-EN ISO 7779:2019-03
92 Low-voltage electrical machines and equipment, including lighting and information technology equipment Temperature (- 60 - +180)° C, Humidity up to 98 % PN-EN 60068-1:2014-06
93 Low-voltage electrical machines and equipment, including lighting and information technology equipment Cold PN-EN 60068-2-1:2009
94 Low-voltage electrical machines and equipment, including lighting and information technology equipment Dry heat PN-EN 60068-2-2:2009
95 Low-voltage electrical machines and equipment, including lighting and information technology equipment Damp heat, cyclic (12h+12h) PN-EN 60068-2-30:2008
96 Low-voltage electrical machines and equipment, including lighting and information technology equipment Damp heat, steady state PN-EN 60068-2-78:2013-11
97 Low-voltage electrical machines and equipment, including lighting and information technology equipment Temperature changes PN-EN IEC 60068-2-14:2024-04
98 Low-voltage electrical machines and equipment, including lighting and information technology equipment Resistance to ingress of solid objects, dust and moisture up to IP 68 PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 excluding degree of protection IP X9 (cl. 14)
99 Electrotechnical products Glow-wire test PN-EN IEC 60695-2-10:2022-07 | PN-EN IEC 60695-2-11:2022-07 | PN-EN IEC 60695-2-12:2022-06 | PN-EN IEC 60695-2-13:2022-05
100 Electrotechnical products Ball pressure test PN-EN 60695-10-2:2014-10
101 Electrotechnical products Needle-flame test PN-EN 60695-11-5:2017-08
102 Electrotechnical products Resistance to tracking currents PN-EN 60112:2021-07
103 Low-voltage electrical machinery and equipment, including lighting, IT and traction equipment Emission of conducted disturbances:
emission of continuous conducted disturbances from 9 kHz up to 30 MHz disturbance power (30-300) MHz - voltage fluctuations and flicker current harmonics up to 39 harmonic radiated electromagnetic disturbances of lighting equipment in the range from 9 kHz up to 30 MHz
PN-EN IEC 61000-6-3:2021-08 | PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN 61000-6-4:2019-12 | PN-EN 55014-1:2021-08 | PN-EN 55014-1:2017-06 | PN-EN 55015 :2019-10/A11:2020 | PN-EN 55015:2013-10/A1:2015-08 | PN-EN 55015:2019-11 | PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 50561-1:2013-12 | PN-EN 50121-1:2015-10 | PN-EN 50121-1:2017-06 | PN-EN 50121-2:2015-10 | PN-EN 50121-2:2017-06 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50121-4:2015-10 | PN-EN 50121-4:2017-04 | PN-EN 50121-5:2015-10 | PN-EN 50121-5:2017-05 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 55022:2011 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A1:2021-05 | PN-EN 60601-1-2:2015-11 | PN-EN 50130-4:2012 | PN-EN 50130-4:2012/A1:2015-03 | PN-EN 50270:2015-04 | PN-EN 50550:2011 | PN-EN 50550:2011/A1:2015-04, | PN-EN 61204-3:2019-02 | PN-EN IEC 61326-1:2021-10 | PN-EN 61326-2-1:2013-07 | PN-EN IEC 61326-2-2:2021-11 | PN-EN IEC 61326-2-3:2021-11 | PN-EN 61326-2-4:2021-11 | PN-EN IEC 61326-2-5:2021-11 – excluding the clauses concerning measurement of radiated emission and testing of immunity to radiated radio-frequency electromagnetic fields.
104 Low-voltage electrical machinery and equipment, including lighting, IT and traction equipment Immunity to electromagnetic disturbances:
electrostatic discharges (ESD) contact and air ± 30kV electrical fast transients/bursts (BURST) surges (SURGE) immunity to radio-frequency induced disturbances dips, short interruptions and voltage variations
PN-EN IEC 55014-2:2021-08 | PN-EN IEC 55035:2017-09 | PN-EN IEC 55035:2017-09/A11:2020-09 | PN-EN IEC 61000-4-11:2020-11 | PN-EN 55024:2011 | PN-EN 55024:2011/A1:2015-08 | PN-EN 61000-6-1:2008 | PN-EN 61000-6-1:2019-03 | PN-EN 61000-6-2:2008 | PN-EN 61000-6-2:2019-04 | PN-EN 61547:2009 | PN-EN 50121-1:2015-10 | PN-EN 50121-2:2017-06 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50121-4:2015-10 | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | PN-EN 50121-5:2015-10 | PN-EN 50121-5:2017-05 | PN-EN 61000-4-2 :2011 | PN-EN 61000-4-4:2013-05 | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5 2014-10/A1:2018-01 | PN-EN 61000-4-6:2014-04 | PN-EN 61000-4-11:2007 | PN-EN 61000-4-11:2007/A1:2017-09 | PN-EN 60601-1-2:2015-11 | PN-EN 50130-4:2012 | PN-EN 50130-4:2012/A1:2015-03 | PN-EN 50270:2015-04 | PN-EN 50550:2011 | PN-EN 50550:2011/A1:2015-04, | PN-EN 61204-3:2019-02 | PN-EN IEC 61326-1:2021-10 | PN-EN IEC 61326-2-1:2021-10 | PN-EN IEC 61326-2-2:2021-11 | PN-EN IEC 61326-2-3:2021-11 | PN-EN 61326-2-4:2021-11 | PN-EN IEC 61326-2-5:2021-11 – excluding the clauses concerning measurement of radiated emission and testing of immunity to radiated radio-frequency electromagnetic fields.
105 Low-voltage electrical machinery and equipment, including lighting, IT and traction equipment Immunity to voltage dips and voltage variations at the power port PN-EN 61000-4-29:2004
106 Low-voltage electrical machinery and equipment, including lighting, IT and traction equipment Immunity to power-frequency magnetic field PN-EN 61000-4-8:2010
107 Low-voltage electrical machinery and equipment, including lighting, IT and traction equipment Immunity to pulse magnetic field PN-EN 61000-4-9:2016-11
108 Low-voltage electrical machinery and equipment, including lighting, IT and traction equipment Immunity to damped oscillatory wave PN-EN 61000-4-18:2009 | PN-EN 61000-4-18:2009/A1:2011 | PN-EN 61000-4-18:2019-08
109 Low-voltage electrical machinery and equipment, including lighting, IT and traction equipment Immunity to conducted common mode disturbances at frequencies from 0 Hz to 150 kHz PN-EN 61000-4-16:2016-05
110 Low-voltage electrical machinery and equipment, including lighting, IT and traction equipment Immunity to low-frequency disturbances PN-EN 61000-4-13:2007 +A1:2010+A2:2016-05
111 Low-voltage electrical machinery and equipment, including lighting, IT and traction equipment Immunity to voltage fluctuations PN-EN 61000-4-14:2002 +A1:2006+A2:2010
112 Low-voltage electrical machinery and equipment, including lighting, IT and traction equipment Immunity to ripple on the DC input power port PN-EN 61000-4-17:2004 +A1:2006+A2:2011
113 Low-voltage electrical machinery and equipment, including lighting, IT and traction equipment Immunity to power frequency variations PN-EN 61000-4-28:2004 +A1:2006+A2:2011

Reference standards (272)

IEC 60076-10:2016
PN-E-53100:2022-05
PN-E-93201:2021-05
PN-E-93202:1997
PN-E-93202:1997/Az:2004
PN-EN 12464-1:2022-01
PN-EN 12464-2:2014-05
PN-EN 12464-2:2014-05 CIE Publication 15:2004
PN-EN 12966+A1:2019-02
PN-EN 12966+A1:2019-02 CIE Publication 15:2004
PN-EN 13032-1+A1:2012
PN-EN 13032-1+A1:2012 CIE Publication 084:1989
PN-EN 13032-1+A1:2012 CIE Publication 13.3:1995 CIE Publication 15:20 CIE Publication 084:1989 CIE Publication 63:1984
PN-EN 13032-1+A1:2012 CIE Publication 13.3:1995 CIE Publication 15:2004 CIE Publication 084:1989
PN-EN 13032-1+A1:2012 CIE Publication 13.3:1995 CIE Publication 15:2004 CIE Publication 084:1989 CIE Publication 63:1984
PN-EN 13032-2:2018-02
PN-EN 13032-3:2022-04
PN-EN 13032-3:2022-04 CIE Publication No. 43
PN-EN 13272-1:2020-03
PN-EN 13272-2:2020-03
PN-EN 13272-2:2020-03 CIE Publication 15:2004
PN-EN 15153+A1:2016-12
PN-EN 15153-1:2020-06
PN-EN 1837:2021-05
PN-EN 1838:2013-11
PN-EN 25580:1997
PN-EN 50121-1:2015-10
PN-EN 50121-1:2017-06
PN-EN 50121-2:2015-10
PN-EN 50121-2:2017-06
PN-EN 50121-3-2:2017-04
PN-EN 50121-3-2:2017-04/A1:2019-07
PN-EN 50121-4:2015-10
PN-EN 50121-4:2017-04
PN-EN 50121-4:2017-04/A1:2019-07
PN-EN 50121-5:2015-10
PN-EN 50121-5:2017-05
PN-EN 50130-4:2012
PN-EN 50130-4:2012/A1:2015-03
PN-EN 50270:2015-04
PN-EN 50550:2011
PN-EN 50550:2011/A1:2015-04,
PN-EN 50561-1:2013-12
PN-EN 55011:2016-05
PN-EN 55011:2016-05/A1:2017-06
PN-EN 55014-1:2017-06
PN-EN 55014-1:2021-08
PN-EN 55015 :2019-10/A11:2020
PN-EN 55015:2013-10/A1:2015-08
PN-EN 55015:2019-11
PN-EN 55022:2011
PN-EN 55024:2011
PN-EN 55024:2011/A1:2015-08
PN-EN 55032:2015-09
PN-EN 55032:2015-09/A1:2021-05
PN-EN 60064:2002
PN-EN 60064:2002/A11:2008
PN-EN 60064:2002/A2:2003
PN-EN 60064:2002/A3:2006
PN-EN 60064:2002/A4:2007
PN-EN 60064:2002/A5:2010
PN-EN 60068-1:2014-06
PN-EN 60068-2-1:2009
PN-EN 60068-2-2:2009
PN-EN 60068-2-30:2008
PN-EN 60068-2-78:2013-11
PN-EN 60076-10:2017-01
PN-EN 60079-35-2:2012
PN-EN 60081:2002
PN-EN 60081:2002/A11:2018-10
PN-EN 60081:2002/A2:2005
PN-EN 60081:2002/A3:2006
PN-EN 60081:2002/A4:2010
PN-EN 60081:2002/A5:2014-02
PN-EN 60081:2002/A6:2018-02
PN-EN 60112:2021-07
PN-EN 60188:2004
PN-EN 60188:2004/A11:2019-09
PN-EN 60335-2-15:2016-04
PN-EN 60335-2-15:2016-04/A11:2018-10
PN-EN 60335-2-15:2016-04/A12:2022-03
PN-EN 60335-2-15:2016-04/A1:2021-11
PN-EN 60335-2-15:2016-04/A2:2021-12
PN-EN 60335-2-27:2014-02
PN-EN 60335-2-27:2014-02/A1:2020-10
PN-EN 60335-2-27:2014-02/A2:2020-08
PN-EN 60335-2-29:2022-05
PN-EN 60335-2-29:2022-05/A1:2022-06
PN-EN 60335-2-31:2015-02
PN-EN 60335-2-31:2015-02/A11:2023-10
PN-EN 60335-2-31:2015-02/A1:2023-09
PN-EN 60335-2-31:2015-02/A2:2023-09
PN-EN 60335-2-59:2007
PN-EN 60335-2-59:2007/A11:2018-12
PN-EN 60335-2-59:2007/A2:2010
PN-EN 60357:2003
PN-EN 60357:2003/A11:2016-12
PN-EN 60357:2003/A1:2008
PN-EN 60357:2003/A2:2009
PN-EN 60357:2003/A3:2011
PN-EN 60432-1:2001
PN-EN 60432-1:2001/A1:2006
PN-EN 60432-1:2001/A2:2012
PN-EN 60432-2:2001
PN-EN 60432-2:2001/A1:2007
PN-EN 60432-2:2001/A2:2012
PN-EN 60432-3:2013-06
PN-EN 60529:2003
PN-EN 60529:2003/A2:2014-07 excluding degree of protection IP X9 (cl. 14)
PN-EN 60598-2-10:2005
PN-EN 60598-2-11:2014-01
PN-EN 60598-2-11:2014-01/A1:2023-03
PN-EN 60598-2-12:2013-12
PN-EN 60598-2-13:2007
PN-EN 60598-2-13:2007/A11:2021-09 excluding the pressure resistance tests
PN-EN 60598-2-13:2007/A1:2012
PN-EN 60598-2-13:2007/A2:2017-02
PN-EN 60598-2-19:2002
PN-EN 60598-2-20:2015-07
PN-EN 60598-2-24:2014-02
PN-EN 60598-2-25:2000
PN-EN 60598-2-25:2000/A1:2005
PN-EN 60598-2-3:2006
PN-EN 60598-2-3:2006/A1:2012
PN-EN 60598-2-4:2018-06
PN-EN 60598-2-5:2016-02
PN-EN 60598-2-8:2013-12
PN-EN 60598-2-9:2002
PN-EN 60601-1-2:2015-11
PN-EN 60601-1:2011
PN-EN 60601-1:2011/A1:2014-02
PN-EN 60601-1:2011/A2:2022-03
PN-EN 60662:2012
PN-EN 60662:2012 /A11:2019-11
PN-EN 60695-10-2:2014-10
PN-EN 60695-11-5:2017-08
PN-EN 60901:2002
PN-EN 60901:2002/A3:2005
PN-EN 60901:2002/A4:2008
PN-EN 60901:2002/A5:2012
PN-EN 60901:2002/A6:2018-02
PN-EN 60921:2005
PN-EN 60921:2005/A1:2006
PN-EN 60923:2006
PN-EN 60923:2006/A1:2006
PN-EN 60927:2007
PN-EN 60927:2007/A1:2014-04
PN-EN 60929:2011
PN-EN 60929:2011/A1:2016-05
PN-EN 60968:2015-12
PN-EN 60969:2002
PN-EN 61000-3-2:2014-10
PN-EN 61000-3-2:2019-04
PN-EN 61000-3-3:2013-10
PN-EN 61000-3-3:2013-10/A1:2019-10
PN-EN 61000-4-11:2007
PN-EN 61000-4-11:2007/A1:2017-09
PN-EN 61000-4-13:2007 +A1:2010+A2:2016-05
PN-EN 61000-4-14:2002 +A1:2006+A2:2010
PN-EN 61000-4-16:2016-05
PN-EN 61000-4-17:2004 +A1:2006+A2:2011
PN-EN 61000-4-18:2009
PN-EN 61000-4-18:2009/A1:2011
PN-EN 61000-4-18:2019-08
PN-EN 61000-4-2 :2011
PN-EN 61000-4-28:2004 +A1:2006+A2:2011
PN-EN 61000-4-29:2004
PN-EN 61000-4-4:2013-05
PN-EN 61000-4-5 2014-10/A1:2018-01
PN-EN 61000-4-5:2014-10
PN-EN 61000-4-6:2014-04
PN-EN 61000-4-8:2010
PN-EN 61000-4-9:2016-11
PN-EN 61000-6-1:2008
PN-EN 61000-6-1:2019-03
PN-EN 61000-6-2:2008
PN-EN 61000-6-2:2019-04
PN-EN 61000-6-4:2008
PN-EN 61000-6-4:2008/A1:2012
PN-EN 61000-6-4:2019-12
PN-EN 61047:2005
PN-EN 61167:2019-01
PN-EN 61167:2019-01/A1:2019-03
PN-EN 61195:2005
PN-EN 61195:2005/A1:2013-06
PN-EN 61195:2005/A2:2015-04
PN-EN 61199:2011
PN-EN 61199:2011/A1:2013-06
PN-EN 61199:2011/A2:2015-04
PN-EN 61204-3:2019-02
PN-EN 61242:2001
PN-EN 61242:2001/A13:2017-05
PN-EN 61242:2001/A1:2010
PN-EN 61242:2001/A2:2016-03
PN-EN 61326-2-1:2013-07
PN-EN 61326-2-4:2021-11
PN-EN 61347-1:2015-09
PN-EN 61347-1:2015-09/A1:2021-06
PN-EN 61347-2-10:2002
PN-EN 61347-2-10:2002/A1:2009
PN-EN 61347-2-11:2005
PN-EN 61347-2-11:2005/A1:2019-09
PN-EN 61347-2-12:2006
PN-EN 61347-2-12:2006/A1:2011
PN-EN 61347-2-13:2015-04
PN-EN 61347-2-13:2015-04/A1:2017-07
PN-EN 61347-2-1:2005
PN-EN 61347-2-1:2005/A1:2007
PN-EN 61347-2-1:2005/A2:2014-04
PN-EN 61347-2-2:2012
PN-EN 61347-2-3:2011
PN-EN 61347-2-3:2011/A1:2017-07
PN-EN 61347-2-7:2012
PN-EN 61347-2-7:2012 /A1:2019-11
PN-EN 61347-2-7:2012/A1:2019-11
PN-EN 61347-2-7:2012/A2:2022-11
PN-EN 61347-2-8:2003
PN-EN 61347-2-8:2003/A1:2007
PN-EN 61347-2-9:2013-06
PN-EN 61547:2009
PN-EN 62035:2015-05
PN-EN 62035:2015-05/A1:2019-11
PN-EN 62271-202:2014 -12/ AC1:2015-07
PN-EN 62271-202:2014-12
PN-EN IEC 55014-2:2021-08
PN-EN IEC 55035:2017-09
PN-EN IEC 55035:2017-09/A11:2020-09
PN-EN IEC 60068-2-14:2024-04
PN-EN IEC 60335-1:2024-04
PN-EN IEC 60335-2-14:2024-03
PN-EN IEC 60335-2-14:2024-03/A1:2024-06
PN-EN IEC 60335-2-82:2022-08
PN-EN IEC 60335-2-89:2022-12
PN-EN IEC 60335-2-89:2022-12/A11:2023-04
PN-EN IEC 60598-1:2021-07
PN-EN IEC 60598-1:2021-07/A11:2022-12
PN-EN IEC 60598-2-17:2018-05
PN-EN IEC 60598-2-18:2023-05
PN-EN IEC 60598-2-1:2021-09
PN-EN IEC 60598-2-22:2022-11
PN-EN IEC 60598-2-23:2021-06
PN-EN IEC 60598-2-2:2024-06
PN-EN IEC 60695-2-10:2022-07
PN-EN IEC 60695-2-11:2022-07
PN-EN IEC 60695-2-12:2022-06
PN-EN IEC 60695-2-13:2022-05
PN-EN IEC 61000-4-11:2020-11
PN-EN IEC 61000-6-3:2021-08
PN-EN IEC 61326-1:2021-10
PN-EN IEC 61326-2-1:2021-10
PN-EN IEC 61326-2-2:2021-11
PN-EN IEC 61326-2-3:2021-11
PN-EN IEC 61326-2-5:2021-11 – excluding the clauses concerning measurement of radiated emission and testing of immunity to radiated radio-frequency electromagnetic fields.
PN-EN IEC 62115:2020-04
PN-EN IEC 62115:2020-04/A11:2020-07
PN-EN ISO 1680:2014-02
PN-EN ISO 3743-1:2011
PN-EN ISO 3744:2011 excluding, cl. 8.3.
PN-EN ISO 3746:2011
PN-EN ISO 3746:2011/AP1:2017-09
PN-EN ISO 3747:2011
PN-EN ISO 5580:2024-06
PN-EN ISO 7779:2019-03
PN-EN ISO 9295:2015-09
PN-IEC 60884-1:2024-04
PN-IEC 60884-2-2:2012
PN-IEC 60884-2-3:2012
PN-IEC 60884-2-5:2021:03
CIE Publication 084:1989
CIE Publication 15:2004
CIE Publication 15:2004 CIE Publication 13.3:1995 CIE Publication 63:1984
CIE Publication No. 43

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20022