🇨🇿 OPTOKON, a.s. PL

ČIA 1755 • Jihlava, Czech Republic • 10 methods

Electronics & EMC

OPTOKON, a.s. is a laboratory accredited by ČIA under number 1755 (Jihlava, Czech Republic). Its accreditation scope covers 10 test methods in the following areas: Electronics & EMC. Test objects include: Electrical and electronic equipment, vehicle assemblies and subasse…, Optical cables and fibres, Optical cables.

At a glance

  • Accreditation number: ČIA 1755
  • Methods in scope: 10
  • Types of test objects: 3
  • City: Jihlava, Czech Republic
  • Valid until: 26-10-2028
Accreditation number
1755
Accreditation body
ČIA
Address
Červený Kříž 250, 586 01 Jihlava
City
Jihlava, Czech Republic
Division
OPTOKON Testing Laboratory
Valid until
26-10-2028

What this laboratory tests (3)

Certificate information

Certificate date
11.02.2026

Accreditation scope — test methods (10)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Optical cables and fibres Temperature cycling resistance test PPZL 2.11 (ČSN EN 60794-1-22, Method F1)
2 Optical cables and fibres Ageing resistance test PPZL 2.12 (ČSN EN 60794-1-22, Method F9)
3 Optical cables External freezing resistance test PPZL 2.13 (ČSN EN 60794-1-22, Method F15)
4 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Conducted emissions, radio frequency potential, power leads MIL-STD-461 Method CE102; ČOS 599902 Method CE102
5 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Radiated emissions, electric field MIL-STD-461 Method RE102; ČOS 599902 Method RE102; ČSN EN IEC 55025 ed. 4, cl. 6.4 and 6.5; CISPR 25:2021, cl. 6.4 and 6.5
6 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Conducted susceptibility, power leads MIL-STD-461 Method CS101; ČOS 599902 Method CS101
7 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Conducted susceptibility, bulk cable injection MIL-STD-461 Method CS114; ČOS 599902 Method CS114
8 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Conducted susceptibility, bulk cable injection, impulse excitation MIL-STD-461 Method CS115; ČOS 599902 Method CS115
9 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Conducted susceptibility, damped sinusoid, cables and power leads MIL-STD-461 Method CS116; ČOS 599902 Method CS116
10 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Radiated susceptibility, transient electromagnetic field MIL-STD-461 Method RS103; ČOS 599902 Method RS103

Reference standards (22)

CISPR 25:2021, cl. 6.4 and 6.5
MIL-STD-461 Method CE102
MIL-STD-461 Method CS101
MIL-STD-461 Method CS114
MIL-STD-461 Method CS115
MIL-STD-461 Method CS116
MIL-STD-461 Method RE102
MIL-STD-461 Method RS103
PPZL 2.11
PPZL 2.12
PPZL 2.13
ČOS 599902 Method CE102
ČOS 599902 Method CS101
ČOS 599902 Method CS114
ČOS 599902 Method CS115
ČOS 599902 Method CS116
ČOS 599902 Method RE102
ČOS 599902 Method RS103
ČSN EN 60794-1-22, metoda F1
ČSN EN 60794-1-22, metoda F15
ČSN EN 60794-1-22, metoda F9
ČSN EN IEC 55025 ed. 4, cl. 6.4 and 6.5