🇨🇿 SQZ, s.r.o. PL
ConstructionEnvironment
SQZ, s.r.o. is a laboratory accredited by ČIA under number 1135.1 (Olomouc, Czech Republic). Its accreditation scope covers 463 test methods in the following areas: Construction, Environment. Test objects include: Aggregates, Bituminous mixtures, Hardened concrete, Fresh concrete.
At a glance
- Accreditation number: ČIA 1135.1
- Methods in scope: 463
- Types of test objects: 36
- City: Olomouc, Czech Republic
- Valid until: 29-07-2029
- Accreditation number
- 1135.1
- Accreditation body
- ČIA
- Address
- U místní dráhy 939/5, Nová Ulice, 779 00 Olomouc
- City
- Olomouc, Czech Republic
- Division
- SQZ Laboratories
- Valid until
- 29-07-2029
What this laboratory tests (36)
- Aggregates — 84 methods
- Bituminous mixtures — 81 methods
- Hardened concrete — 61 methods
- Fresh concrete — 35 methods
- Unbound and bound mixtures, soils — 35 methods
- Soils — 24 methods
- Bituminous layers — 22 methods
- Road surface — 18 methods
- Mortars — 14 methods
- Bituminous binders — 11 methods
- Concrete structures and elements, insulation layers — 10 methods
- Hydraulically bound mixtures — 9 methods
- Geotextiles — 6 methods
- Working environment — 5 methods
- Cements — 4 methods
- and 21 more
Laboratory sections (14)
- Olomouc — 86 methods
- Zbraslav – transport infrastructure laboratory — 71 methods
- Srch — 54 methods
- Dobřany — 51 methods
- Zbraslav – special concrete laboratory — 43 methods
- Chotýšany — 32 methods
- Trocnov — 31 methods
- Bílý Kámen — 27 methods
- České Budějovice — 14 methods
- Chvaletice — 14 methods
- Kařez — 14 methods
- Louny — 14 methods
- Physical quantities — 9 methods
- Sewer measurement — 3 methods
Laboratory locations
- SQZ, s.r.o. (main site) — U místní dráhy 939/5, Nová Ulice, 779 00 Olomouc
- Olomouc — U místní dráhy 939/5, Nová Ulice, 779 00 Olomouc
- Chotýšany — Městečko 51, 257 28 Chotýšany
- Zbraslav – transport infrastructure laboratory — K Výtopně 1226, 156 00 Praha – Zbraslav
- Zbraslav – special concrete laboratory — K Výtopně 1226, 156 00 Praha – Zbraslav
- Kařez — areál obalovny Kařez, 338 08 Zbiroh
- Louny — Postoloprtská 2956, 440 01 Louny
- Dobřany — Dvořákova 998, 334 41 Dobřany
- Bílý Kámen — Kamenolom Bílý Kámen, 588 41 Vyskytná nad Jihlavou
- Srch — Boční 229, 533 52 Srch
- Trocnov — Trocnov 65, 373 12 Borovany
- Sewer measurement — U místní dráhy 939/5, Nová Ulice, 779 00 Olomouc
- Physical quantities — K Výtopně 1226, 156 00 Praha – Zbraslav
- Chvaletice — K Elektrárně 491, 533 12 Chvaletice
- České Budějovice — Okružní 641, 370 01 České Budějovice
Certificate information
- Certificate date
- 30.03.2026
Accreditation scope — test methods (463)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Olomouc | |||||
| 1 | Bituminous binders | Determination of needle penetration Regulated area: 1 Bituminous binders |
ČSN EN 1426 | ||
| 2 | Bituminous binders | Determination of the softening point – ring and ball method Regulated area: 1 Bituminous binders |
ČSN EN 1427 | ||
| 3 | Bituminous binders | Determination of adhesion Regulated area: 1 Bituminous binders |
ČSN 73 6161 | ||
| 4 | Bituminous mixtures | Determination of soluble binder content Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-1 | ||
| 5 | Bituminous mixtures | Determination of particle size distribution Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-2 | ||
| 6 | Bituminous mixtures | Determination of maximum density Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-5 | ||
| 7 | Bituminous mixtures | Determination of bulk density of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-6; STN EN 12697-6 | ||
| 8 | Bituminous mixtures | Determination of void characteristics Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-8 | ||
| 9 | Bituminous mixtures | Temperature measurement Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-13 | ||
| 10 | Bituminous mixtures | Determination of binder drainage Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-18, cl. 5 | ||
| 11 | Bituminous mixtures | Wheel tracking test (small-size device) Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-22+A1; STN EN 12697-22+A1 | ||
| 12 | Bituminous mixtures | Determination of the water sensitivity of specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-12, Method A; STN EN 12697-12, Method A | ||
| 13 | Bituminous mixtures | Determination of the dimensions of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-29, cl. 5.2, 5.3; STN EN 12697-29, cl. 5.2, 5.3 | ||
| 14 | Bituminous mixtures | Marshall test Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-34 | ||
| 15 | Bituminous layers | Determination of thickness Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-36, cl. 6.1 | ||
| 16 | Bituminous layers | Testing of the finished layer – degree of compaction Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.2, method a), c) | ||
| 17 | Bituminous layers | Testing of the finished layer – degree of compaction Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.2, method b) | ||
| 18 | Bituminous layers | Interlayer bond shear test Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.3 | ||
| 19 | Bituminous mixtures | Determination of indirect tensile strength Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-23; STN EN 12697-23 | ||
| 20 | Aggregates | Determination of particle size distribution Regulated area: 3 Aggregates |
ČSN EN 933-1 | ||
| 21 | Aggregates | Determination of particle shape – flakiness index Regulated area: 3 Aggregates |
ČSN EN 933-3 | ||
| 22 | Aggregates | Determination of particle shape – shape index Regulated area: 3 Aggregates |
ČSN EN 933-4 | ||
| 23 | Aggregates | Determination of the percentage of crushed particles Regulated area: 3 Aggregates |
ČSN EN 933-5 | ||
| 24 | Aggregates | Assessment of fines – sand equivalent test Regulated area: 3 Aggregates |
ČSN EN 933-8+A1 | ||
| 25 | Aggregates | Assessment of fines – methylene blue test Regulated area: 3 Aggregates |
ČSN EN 933-9 | ||
| 26 | Aggregates | Determination of resistance to fragmentation Regulated area: 3 Aggregates |
ČSN EN 1097-2, cl. 1-5 | ||
| 27 | Aggregates | Determination of loose bulk density and voids Regulated area: 3 Aggregates |
ČSN EN 1097-3, excluding Annex A | ||
| 28 | Aggregates | Determination of water content by drying in a ventilated oven Regulated area: 3 Aggregates |
ČSN EN 1097-5 | ||
| 29 | Aggregates | Determination of particle density and water absorption Regulated area: 3 Aggregates |
ČSN EN 1097-6 | ||
| 30 | Aggregates | Determination of the particle density of filler – pyknometer method Regulated area: 3 Aggregates |
ČSN EN 1097-7 | ||
| 31 | Aggregates | Determination of resistance to thermal and weathering effects – freezing and thawing test Regulated area: 3 Aggregates |
ČSN EN 1367-1 | ||
| 32 | Aggregates | Determination of resistance to thermal and weathering effects – magnesium sulphate test Regulated area: 3 Aggregates |
ČSN EN 1367-2 | ||
| 33 | Aggregates | Determination of durability – accelerated sodium sulphate test Regulated area: 3 Aggregates |
ČSN 72 1176, Method A | ||
| 34 | Aggregates | Determination of dissimilar particles Regulated area: 3 Aggregates |
ČSN 72 1180 | ||
| 35 | Cements | Determination of flexural and compressive strength Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 196-1, excluding chap. 5, 6, 7, 8, 11, Annex A | ||
| 36 | Mortars | Determination of compressive strength on prism halves Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-11, excluding cl. 8 | ||
| 37 | Mortars | Determination of flexural strength Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-11, excluding cl. 9 | ||
| 38 | Grouts | Determination of compressive strength Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 445, cl. 4.6 | ||
| 39 | Screed materials | Determination of flexural and compressive strength Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 13892-2 | ||
| 40 | Mortars | Determination of bulk density Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-10 | ||
| 41 | Fresh concrete | Determination of consistence – slump test Regulated area: 5 Concrete |
ČSN EN 12350-2 | ||
| 42 | Fresh concrete | Determination of consistence – flow table test Regulated area: 5 Concrete |
ČSN EN 12350-5 | ||
| 43 | Fresh concrete | Determination of density Regulated area: 5 Concrete |
ČSN EN 12350-6, excluding cl. 7.4.2.1 | ||
| 44 | Fresh concrete | Determination of air content – pressure method Regulated area: 5 Concrete |
ČSN EN 12350-7, excluding cl. 5 | ||
| 45 | Hardened concrete | Determination of compressive strength of test specimens Regulated area: 5 Concrete |
ČSN EN 12390-3, excluding cl. A.5 | ||
| 46 | Hardened concrete | Determination of flexural strength of test specimens Regulated area: 5 Concrete |
ČSN EN 12390-5 | ||
| 47 | Hardened concrete | Determination of density Regulated area: 5 Concrete |
ČSN EN 12390-7 | ||
| 48 | Hardened concrete | Determination of depth of penetration of water under pressure Regulated area: 5 Concrete |
ČSN EN 12390-8 | ||
| 49 | Hardened concrete | Determination of compressive strength of cores Regulated area: 5 Concrete |
ČSN EN 12504-1, cl. 9 | ||
| 50 | Hardened concrete | Determination of rebound number Regulated area: 5 Concrete |
ČSN EN 12504-2; ČSN 73 1373, excluding Annex A and B | ||
| 51 | Hardened concrete | Determination of the thickness of cement concrete pavement on cores Regulated area: 5 Concrete |
ČSN EN 13863-3 | ||
| 52 | Hardened concrete | Determination of static modulus of elasticity in compression Regulated area: 5 Concrete |
ČSN ISO 1920-10 | ||
| 53 | Hardened concrete | Determination of frost resistance Regulated area: 5 Concrete |
ČSN 73 1322 | ||
| 54 | Hardened concrete | Determination of the resistance of cement concrete surface to water and chemical de-icing agents Regulated area: 5 Concrete |
ČSN 73 1326, Methods A, C | ||
| 55 | Hardened concrete | Determination of void volume Regulated area: 5 Concrete |
ČSN 73 6124-2, Annex A | ||
| 56 | Young sprayed concrete | Determination of compressive strength Regulated area: 5 Concrete |
ČSN EN 14488-2 | ||
| 57 | Sprayed concrete | Determination of thickness on the substrate Regulated area: 5 Concrete |
ČSN EN 14488-6 | ||
| 58 | Silicate materials | Determination of moisture content by drying at elevated temperature Regulated area: 5 Concrete |
ČSN EN ISO 12570 | ||
| 59 | Soils | Determination of water content Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-1 | ||
| 60 | Soils | Determination of particle size distribution Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-4 | ||
| 61 | Soils | Determination of consistency limits – liquid limit, plastic limit Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-12, excluding chap. 5.4 | ||
| 62 | Soils | Determination of minimum and maximum density Regulated area: 6 Soils, sub-base layers |
ČSN 72 1018 | ||
| 63 | Unbound and bound mixtures, soils | Determination of laboratory reference density and water content Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-2, excluding cl. 7.3, 7.6 and Annex B | ||
| 64 | Unbound and bound mixtures, soils | Determination of California bearing ratio, immediate bearing index and linear swelling Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-47 | ||
| 65 | Unbound and bound mixtures, soils | Determination of static deformation modulus – static plate load test Regulated area: 6 Soils, sub-base layers |
ČSN 72 1006, Annex A, B, D | ||
| 66 | Unbound and bound mixtures, soils | Determination of bulk density Regulated area: 6 Soils, sub-base layers |
ČSN 72 1010, Method A, D-1 | ||
| 67 | Unbound and bound mixtures, soils | In situ determination of California bearing ratio and immediate bearing index Regulated area: 6 Soils, sub-base layers |
ČSN 73 6186 | ||
| 68 | Unbound and bound mixtures, soils | Determination of dynamic deformation modulus – light dynamic plate method Regulated area: 6 Soils, sub-base layers |
ČSN 73 6192, group C | ||
| 69 | Hydraulically bound mixtures | Determination of compressive strength Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-41 | ||
| 70 | Hydraulically bound mixtures | Determination of resistance to frost and water Regulated area: 6 Soils, sub-base layers |
ČSN 73 6124-1, Annex A | ||
| 71 | Hydraulically bound mixtures | Determination of indirect tensile strength and water resistance Regulated area: 6 Soils, sub-base layers |
ČSN 73 6147, cl. A.2.5 and A.2.6 | ||
| 72 | Road surface | Measurement of unevenness Regulated area: 7 Road surfaces |
ČSN 73 6175 cl. 8 | ||
| 73 | Road surface | Measurement of unevenness Regulated area: 7 Road surfaces |
ČSN 73 6175 cl. 9 | ||
| 74 | Road surface | Measurement of macrotexture depth by the volumetric patch technique Regulated area: 7 Road surfaces |
ČSN EN 13036-1 | ||
| 75 | Rock bolts | Determination of load-bearing capacity Regulated area: 8 Rock bolts |
IP-SQZ-16 (ČSN EN 1537; ČSN EN 14490; ČSN EN ISO 22477-5) | ||
| 76 | Concrete and reinforced concrete structures | Pile integrity testing – PIT method Regulated area: 10 Concrete and reinforced concrete structures and elements |
IP-SQZ-02 (PIT device manual) | ||
| 77 | Concrete and reinforced concrete structures | Pile integrity testing – CHUM method Regulated area: 10 Concrete and reinforced concrete structures and elements |
IP-SQZ-03 (CHUM device manual) | ||
| 78 | Concrete structures and elements | Determination of adhesion by pull-off test Regulated area: 10 Concrete and reinforced concrete structures and elements |
ČSN EN 1542 | ||
| 79 | Concrete structures and elements, insulation layers | Determination of layer adhesion and tensile strength of surface layers Regulated area: 10 Concrete and reinforced concrete structures and elements |
ČSN 73 6242, Annex B | ||
| 80 | Concrete structures and elements, insulation layers | Determination of concrete cover to steel reinforcement Regulated area: 10 Concrete and reinforced concrete structures and elements |
IP-SQZ-01 (ČSN 73 2011, Annex A) | ||
| 81 | Non-magnetic coatings on magnetic substrates | Measurement of thickness by the magnetic method Regulated area: 11 Coatings on magnetic structures |
ČSN EN ISO 2178 | ||
| 82 | Aggregates | Sampling of aggregates Regulated area: Sampling |
ČSN EN 932-1 | ||
| 83 | Fresh concrete | Sampling of fresh concrete Regulated area: Sampling |
ČSN EN 12350-1 | ||
| 84 | Hardened concrete | Sampling of hardened concrete Regulated area: Sampling |
ČSN EN 12504-1, cl. 1-7 | ||
| 85 | Sprayed concrete | Sampling of fresh and hardened concrete Regulated area: Sampling |
ČSN EN 14488-1 | ||
| 86 | Bituminous mixtures | Sampling of bituminous mixtures Regulated area: Sampling |
ČSN EN 12697-27 | ||
| Chotýšany | |||||
| 87 | Bituminous binders | Determination of needle penetration Regulated area: 1 Bituminous binders |
ČSN EN 1426 | ||
| 88 | Bituminous binders | Determination of the softening point – ring and ball method Regulated area: 1 Bituminous binders |
ČSN EN 1427 | ||
| 89 | Bituminous binders | Determination of elastic recovery Regulated area: 1 Bituminous binders |
ČSN EN 13398; STN EN 13398 | ||
| 90 | Bituminous binders | Determination of adhesion Regulated area: 1 Bituminous binders |
ČSN 73 6161 | ||
| 91 | Bituminous mixtures | Determination of soluble binder content Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-1 | ||
| 92 | Bituminous mixtures | Determination of particle size distribution Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-2 | ||
| 93 | Bituminous mixtures | Determination of maximum density Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-5 | ||
| 94 | Bituminous mixtures | Determination of bulk density of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-6; STN EN 12697-6 | ||
| 95 | Bituminous mixtures | Determination of void characteristics Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-8 | ||
| 96 | Bituminous mixtures | Temperature measurement Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-13 | ||
| 97 | Bituminous mixtures | Determination of binder drainage Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-18, cl. 5 | ||
| 98 | Bituminous mixtures | Wheel tracking test (small-size device) Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-22+A1; STN EN 12697-22+A1 | ||
| 99 | Bituminous mixtures | Determination of the water sensitivity of specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-12, Method A; STN EN 12697-12, Method A | ||
| 100 | Bituminous mixtures | Determination of the dimensions of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-29, cl. 5.2, 5.3; STN EN 12697-29, cl. 5.2, 5.3 | ||
| 101 | Bituminous layers | Determination of thickness Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-36, cl. 6.1 | ||
| 102 | Bituminous layers | Testing of the finished layer – degree of compaction Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.2, method a), c) | ||
| 103 | Bituminous layers | Testing of the finished layer – degree of compaction Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.2, method b) | ||
| 104 | Bituminous layers | Interlayer bond shear test Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.3 | ||
| 105 | Bituminous mixtures | Determination of indirect tensile strength Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-23; STN EN 12697-23 | ||
| 106 | Aggregates | Determination of particle size distribution Regulated area: 3 Aggregates |
ČSN EN 933-1 | ||
| 107 | Aggregates | Determination of particle shape – shape index Regulated area: 3 Aggregates |
ČSN EN 933-4 | ||
| 108 | Aggregates | Assessment of fines – sand equivalent test Regulated area: 3 Aggregates |
ČSN EN 933-8+A1 | ||
| 109 | Aggregates | Assessment of fines – methylene blue test Regulated area: 3 Aggregates |
ČSN EN 933-9 | ||
| 110 | Aggregates | Determination of resistance to fragmentation Regulated area: 3 Aggregates |
ČSN EN 1097-2, cl. 1-5 | ||
| 111 | Aggregates | Determination of water content by drying in a ventilated oven Regulated area: 3 Aggregates |
ČSN EN 1097-5 | ||
| 112 | Aggregates | Determination of particle density and water absorption Regulated area: 3 Aggregates |
ČSN EN 1097-6 | ||
| 113 | Unbound and bound mixtures, soils | Determination of static deformation modulus – static plate load test Regulated area: 6 Soils, sub-base layers |
ČSN 72 1006, Annex A, B, D | ||
| 114 | Unbound and bound mixtures, soils | Determination of dynamic deformation modulus – light dynamic plate method Regulated area: 6 Soils, sub-base layers |
ČSN 73 6192, group C | ||
| 115 | Road surface | Measurement of unevenness Regulated area: 7 Road surfaces |
ČSN 73 6175 cl. 8 | ||
| 116 | Road surface | Measurement of unevenness Regulated area: 7 Road surfaces |
ČSN 73 6175 cl. 9 | ||
| 117 | Aggregates | Sampling of aggregates Regulated area: Sampling |
ČSN EN 932-1 | ||
| 118 | Bituminous mixtures | Sampling of bituminous mixtures Regulated area: Sampling |
ČSN EN 12697-27 | ||
| Chvaletice | |||||
| 119 | Bituminous binders | Determination of needle penetration Regulated area: 1 Bituminous binders |
ČSN EN 1426 | ||
| 120 | Bituminous binders | Determination of the softening point – ring and ball method Regulated area: 1 Bituminous binders |
ČSN EN 1427 | ||
| 121 | Bituminous mixtures | Determination of soluble binder content Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-1 | ||
| 122 | Bituminous mixtures | Determination of particle size distribution Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-2 | ||
| 123 | Bituminous mixtures | Determination of maximum density Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-5 | ||
| 124 | Bituminous mixtures | Determination of bulk density of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-6; STN EN 12697-6 | ||
| 125 | Bituminous mixtures | Determination of void characteristics Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-8 | ||
| 126 | Bituminous mixtures | Temperature measurement Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-13 | ||
| 127 | Bituminous mixtures | Determination of the dimensions of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-29, cl. 5.2, 5.3; STN EN 12697-29, cl. 5.2, 5.3 | ||
| 128 | Aggregates | Determination of particle size distribution Regulated area: 3 Aggregates |
ČSN EN 933-1 | ||
| 129 | Aggregates | Determination of particle shape – shape index Regulated area: 3 Aggregates |
ČSN EN 933-4 | ||
| 130 | Aggregates | Determination of water content by drying in a ventilated oven Regulated area: 3 Aggregates |
ČSN EN 1097-5 | ||
| 131 | Aggregates | Sampling of aggregates Regulated area: Sampling |
ČSN EN 932-1 | ||
| 132 | Bituminous mixtures | Sampling of bituminous mixtures Regulated area: Sampling |
ČSN EN 12697-27 | ||
| České Budějovice | |||||
| 133 | Bituminous binders | Determination of needle penetration Regulated area: 1 Bituminous binders |
ČSN EN 1426 | ||
| 134 | Bituminous binders | Determination of the softening point – ring and ball method Regulated area: 1 Bituminous binders |
ČSN EN 1427 | ||
| 135 | Bituminous mixtures | Determination of soluble binder content Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-1 | ||
| 136 | Bituminous mixtures | Determination of particle size distribution Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-2 | ||
| 137 | Bituminous mixtures | Determination of maximum density Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-5 | ||
| 138 | Bituminous mixtures | Determination of bulk density of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-6; STN EN 12697-6 | ||
| 139 | Bituminous mixtures | Determination of void characteristics Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-8 | ||
| 140 | Bituminous mixtures | Temperature measurement Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-13 | ||
| 141 | Bituminous mixtures | Determination of the dimensions of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-29, cl. 5.2, 5.3; STN EN 12697-29, cl. 5.2, 5.3 | ||
| 142 | Aggregates | Determination of particle size distribution Regulated area: 3 Aggregates |
ČSN EN 933-1 | ||
| 143 | Aggregates | Determination of particle shape – shape index Regulated area: 3 Aggregates |
ČSN EN 933-4 | ||
| 144 | Aggregates | Determination of water content by drying in a ventilated oven Regulated area: 3 Aggregates |
ČSN EN 1097-5 | ||
| 145 | Aggregates | Sampling of aggregates Regulated area: Sampling |
ČSN EN 932-1 | ||
| 146 | Bituminous mixtures | Sampling of bituminous mixtures Regulated area: Sampling |
ČSN EN 12697-27 | ||
| Kařez | |||||
| 147 | Bituminous mixtures | Determination of soluble binder content Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-1 | ||
| 148 | Bituminous mixtures | Determination of particle size distribution Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-2 | ||
| 149 | Bituminous mixtures | Determination of maximum density Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-5 | ||
| 150 | Bituminous mixtures | Determination of bulk density of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-6; STN EN 12697-6 | ||
| 151 | Bituminous mixtures | Determination of void characteristics Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-8 | ||
| 152 | Bituminous mixtures | Temperature measurement Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-13 | ||
| 153 | Bituminous mixtures | Determination of the dimensions of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-29, cl. 5.2, 5.3; STN EN 12697-29, cl. 5.2, 5.3 | ||
| 154 | Bituminous layers | Determination of thickness Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-36, cl. 6.1 | ||
| 155 | Bituminous layers | Testing of the finished layer – degree of compaction Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.2, method a), c) | ||
| 156 | Aggregates | Determination of particle size distribution Regulated area: 3 Aggregates |
ČSN EN 933-1 | ||
| 157 | Aggregates | Determination of particle shape – shape index Regulated area: 3 Aggregates |
ČSN EN 933-4 | ||
| 158 | Aggregates | Determination of water content by drying in a ventilated oven Regulated area: 3 Aggregates |
ČSN EN 1097-5 | ||
| 159 | Aggregates | Sampling of aggregates Regulated area: Sampling |
ČSN EN 932-1 | ||
| 160 | Bituminous mixtures | Sampling of bituminous mixtures Regulated area: Sampling |
ČSN EN 12697-27 | ||
| Louny | |||||
| 161 | Bituminous mixtures | Determination of soluble binder content Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-1 | ||
| 162 | Bituminous mixtures | Determination of particle size distribution Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-2 | ||
| 163 | Bituminous mixtures | Determination of maximum density Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-5 | ||
| 164 | Bituminous mixtures | Determination of bulk density of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-6; STN EN 12697-6 | ||
| 165 | Bituminous mixtures | Determination of void characteristics Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-8 | ||
| 166 | Bituminous mixtures | Temperature measurement Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-13 | ||
| 167 | Bituminous mixtures | Determination of the dimensions of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-29, cl. 5.2, 5.3; STN EN 12697-29, cl. 5.2, 5.3 | ||
| 168 | Bituminous layers | Determination of thickness Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-36, cl. 6.1 | ||
| 169 | Bituminous layers | Testing of the finished layer – degree of compaction Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.2, method a), c) | ||
| 170 | Aggregates | Determination of particle size distribution Regulated area: 3 Aggregates |
ČSN EN 933-1 | ||
| 171 | Aggregates | Determination of particle shape – shape index Regulated area: 3 Aggregates |
ČSN EN 933-4 | ||
| 172 | Aggregates | Determination of water content by drying in a ventilated oven Regulated area: 3 Aggregates |
ČSN EN 1097-5 | ||
| 173 | Aggregates | Sampling of aggregates Regulated area: Sampling |
ČSN EN 932-1 | ||
| 174 | Bituminous mixtures | Sampling of bituminous mixtures Regulated area: Sampling |
ČSN EN 12697-27 | ||
| Dobřany | |||||
| 175 | Bituminous mixtures | Determination of soluble binder content Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-1 | ||
| 176 | Bituminous mixtures | Determination of particle size distribution Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-2 | ||
| 177 | Bituminous mixtures | Determination of maximum density Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-5 | ||
| 178 | Bituminous mixtures | Determination of bulk density of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-6; STN EN 12697-6 | ||
| 179 | Bituminous mixtures | Determination of void characteristics Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-8 | ||
| 180 | Bituminous mixtures | Temperature measurement Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-13 | ||
| 181 | Bituminous mixtures | Determination of the dimensions of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-29, cl. 5.2, 5.3; STN EN 12697-29, cl. 5.2, 5.3 | ||
| 182 | Bituminous layers | Determination of thickness Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-36, cl. 6.1 | ||
| 183 | Bituminous layers | Testing of the finished layer – degree of compaction Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.2, method a), c) | ||
| 184 | Bituminous layers | Testing of the finished layer – degree of compaction Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.2, method b) | ||
| 185 | Bituminous layers | Interlayer bond shear test Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.3 | ||
| 186 | Aggregates | Determination of particle size distribution Regulated area: 3 Aggregates |
ČSN EN 933-1 | ||
| 187 | Aggregates | Determination of particle shape – flakiness index Regulated area: 3 Aggregates |
ČSN EN 933-3 | ||
| 188 | Aggregates | Determination of particle shape – shape index Regulated area: 3 Aggregates |
ČSN EN 933-4 | ||
| 189 | Aggregates | Determination of the percentage of crushed particles Regulated area: 3 Aggregates |
ČSN EN 933-5 | ||
| 190 | Aggregates | Assessment of fines – sand equivalent test Regulated area: 3 Aggregates |
ČSN EN 933-8+A1 | ||
| 191 | Aggregates | Assessment of fines – methylene blue test Regulated area: 3 Aggregates |
ČSN EN 933-9 | ||
| 192 | Aggregates | Determination of resistance to fragmentation Regulated area: 3 Aggregates |
ČSN EN 1097-2, cl. 1-5 | ||
| 193 | Aggregates | Determination of loose bulk density and voids Regulated area: 3 Aggregates |
ČSN EN 1097-3, excluding Annex A | ||
| 194 | Aggregates | Determination of water content by drying in a ventilated oven Regulated area: 3 Aggregates |
ČSN EN 1097-5 | ||
| 195 | Aggregates | Determination of dissimilar particles Regulated area: 3 Aggregates |
ČSN 72 1180 | ||
| 196 | Aggregates | Assessment of fines – loss on drying test Regulated area: 3 Aggregates |
ČSN 72 1187 | ||
| 197 | Mortars | Determination of compressive strength on prism halves Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-11, excluding cl. 8 | ||
| 198 | Mortars | Determination of flexural strength Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-11, excluding cl. 9 | ||
| 199 | Mortars | Determination of bulk density Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-10 | ||
| 200 | Fresh concrete | Determination of consistence – slump test Regulated area: 5 Concrete |
ČSN EN 12350-2 | ||
| 201 | Fresh concrete | Determination of consistence – flow table test Regulated area: 5 Concrete |
ČSN EN 12350-5 | ||
| 202 | Fresh concrete | Determination of density Regulated area: 5 Concrete |
ČSN EN 12350-6, excluding cl. 7.4.2.1 | ||
| 203 | Fresh concrete | Determination of air content – pressure method Regulated area: 5 Concrete |
ČSN EN 12350-7, excluding cl. 5 | ||
| 204 | Hardened concrete | Determination of compressive strength of test specimens Regulated area: 5 Concrete |
ČSN EN 12390-3, excluding cl. A.5 | ||
| 205 | Hardened concrete | Determination of density Regulated area: 5 Concrete |
ČSN EN 12390-7 | ||
| 206 | Hardened concrete | Determination of depth of penetration of water under pressure Regulated area: 5 Concrete |
ČSN EN 12390-8 | ||
| 207 | Hardened concrete | Determination of compressive strength of cores Regulated area: 5 Concrete |
ČSN EN 12504-1, cl. 9 | ||
| 208 | Hardened concrete | Determination of rebound number Regulated area: 5 Concrete |
ČSN EN 12504-2; ČSN 73 1373, excluding Annex A and B | ||
| 209 | Hardened concrete | Determination of the resistance of cement concrete surface to water and chemical de-icing agents Regulated area: 5 Concrete |
ČSN 73 1326, Methods A, C | ||
| 210 | Soils | Determination of water content Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-1 | ||
| 211 | Soils | Determination of particle size distribution Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-4 | ||
| 212 | Soils | Determination of consistency limits – liquid limit, plastic limit Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-12, excluding chap. 5.4 | ||
| 213 | Soils | Determination of minimum and maximum density Regulated area: 6 Soils, sub-base layers |
ČSN 72 1018 | ||
| 214 | Unbound and bound mixtures, soils | Determination of laboratory reference density and water content Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-2, excluding cl. 7.3, 7.6 and Annex B | ||
| 215 | Unbound and bound mixtures, soils | Determination of California bearing ratio, immediate bearing index and linear swelling Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-47 | ||
| 216 | Unbound and bound mixtures, soils | Determination of static deformation modulus – static plate load test Regulated area: 6 Soils, sub-base layers |
ČSN 72 1006, Annex A, B, D | ||
| 217 | Unbound and bound mixtures, soils | Determination of bulk density Regulated area: 6 Soils, sub-base layers |
ČSN 72 1010, Method A, D-1 | ||
| 218 | Unbound and bound mixtures, soils | Determination of dynamic deformation modulus – light dynamic plate method Regulated area: 6 Soils, sub-base layers |
ČSN 73 6192, group C | ||
| 219 | Road surface | Measurement of unevenness Regulated area: 7 Road surfaces |
ČSN 73 6175 cl. 8 | ||
| 220 | Road surface | Measurement of unevenness Regulated area: 7 Road surfaces |
ČSN 73 6175 cl. 9 | ||
| 221 | Concrete structures and elements, insulation layers | Determination of layer adhesion and tensile strength of surface layers Regulated area: 10 Concrete and reinforced concrete structures and elements |
ČSN 73 6242, Annex B | ||
| 222 | Aggregates | Sampling of aggregates Regulated area: Sampling |
ČSN EN 932-1 | ||
| 223 | Fresh concrete | Sampling of fresh concrete Regulated area: Sampling |
ČSN EN 12350-1 | ||
| 224 | Hardened concrete | Sampling of hardened concrete Regulated area: Sampling |
ČSN EN 12504-1, cl. 1-7 | ||
| 225 | Bituminous mixtures | Sampling of bituminous mixtures Regulated area: Sampling |
ČSN EN 12697-27 | ||
| Bílý Kámen | |||||
| 226 | Bituminous mixtures | Determination of soluble binder content Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-1 | ||
| 227 | Bituminous mixtures | Determination of particle size distribution Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-2 | ||
| 228 | Bituminous mixtures | Determination of maximum density Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-5 | ||
| 229 | Bituminous mixtures | Determination of bulk density of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-6; STN EN 12697-6 | ||
| 230 | Bituminous mixtures | Determination of void characteristics Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-8 | ||
| 231 | Bituminous mixtures | Temperature measurement Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-13 | ||
| 232 | Bituminous mixtures | Determination of the dimensions of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-29, cl. 5.2, 5.3; STN EN 12697-29, cl. 5.2, 5.3 | ||
| 233 | Bituminous layers | Determination of thickness Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-36, cl. 6.1 | ||
| 234 | Bituminous layers | Testing of the finished layer – degree of compaction Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.2, method a), c) | ||
| 235 | Aggregates | Determination of particle size distribution Regulated area: 3 Aggregates |
ČSN EN 933-1 | ||
| 236 | Aggregates | Determination of particle shape – shape index Regulated area: 3 Aggregates |
ČSN EN 933-4 | ||
| 237 | Aggregates | Assessment of fines – sand equivalent test Regulated area: 3 Aggregates |
ČSN EN 933-8+A1 | ||
| 238 | Aggregates | Determination of water content by drying in a ventilated oven Regulated area: 3 Aggregates |
ČSN EN 1097-5 | ||
| 239 | Fresh concrete | Determination of consistence – slump test Regulated area: 5 Concrete |
ČSN EN 12350-2 | ||
| 240 | Fresh concrete | Determination of density Regulated area: 5 Concrete |
ČSN EN 12350-6, excluding cl. 7.4.2.1 | ||
| 241 | Fresh concrete | Determination of air content – pressure method Regulated area: 5 Concrete |
ČSN EN 12350-7, excluding cl. 5 | ||
| 242 | Soils | Determination of water content Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-1 | ||
| 243 | Soils | Determination of particle size distribution Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-4 | ||
| 244 | Soils | Determination of consistency limits – liquid limit, plastic limit Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-12, excluding chap. 5.4 | ||
| 245 | Unbound and bound mixtures, soils | Determination of laboratory reference density and water content Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-2, excluding cl. 7.3, 7.6 and Annex B | ||
| 246 | Unbound and bound mixtures, soils | Determination of static deformation modulus – static plate load test Regulated area: 6 Soils, sub-base layers |
ČSN 72 1006, Annex A, B, D | ||
| 247 | Unbound and bound mixtures, soils | Determination of bulk density Regulated area: 6 Soils, sub-base layers |
ČSN 72 1010, Method A, D-1 | ||
| 248 | Unbound and bound mixtures, soils | Determination of dynamic deformation modulus – light dynamic plate method Regulated area: 6 Soils, sub-base layers |
ČSN 73 6192, group C | ||
| 249 | Road surface | Measurement of unevenness Regulated area: 7 Road surfaces |
ČSN 73 6175 cl. 8 | ||
| 250 | Aggregates | Sampling of aggregates Regulated area: Sampling |
ČSN EN 932-1 | ||
| 251 | Fresh concrete | Sampling of fresh concrete Regulated area: Sampling |
ČSN EN 12350-1 | ||
| 252 | Bituminous mixtures | Sampling of bituminous mixtures Regulated area: Sampling |
ČSN EN 12697-27 | ||
| Srch | |||||
| 253 | Bituminous mixtures | Determination of soluble binder content Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-1 | ||
| 254 | Bituminous mixtures | Determination of particle size distribution Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-2 | ||
| 255 | Bituminous mixtures | Determination of maximum density Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-5 | ||
| 256 | Bituminous mixtures | Determination of bulk density of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-6; STN EN 12697-6 | ||
| 257 | Bituminous mixtures | Determination of void characteristics Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-8 | ||
| 258 | Bituminous mixtures | Temperature measurement Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-13 | ||
| 259 | Bituminous mixtures | Determination of the dimensions of bituminous specimens Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-29, cl. 5.2, 5.3; STN EN 12697-29, cl. 5.2, 5.3 | ||
| 260 | Bituminous layers | Determination of thickness Regulated area: 2 Bituminous mixtures and layers |
ČSN EN 12697-36, cl. 6.1 | ||
| 261 | Bituminous layers | Testing of the finished layer – degree of compaction Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.2, method a), c) | ||
| 262 | Bituminous layers | Testing of the finished layer – degree of compaction Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.2, method b) | ||
| 263 | Bituminous layers | Interlayer bond shear test Regulated area: 2 Bituminous mixtures and layers |
ČSN 73 6160, cl. 7.3 | ||
| 264 | Aggregates | Determination of particle size distribution Regulated area: 3 Aggregates |
ČSN EN 933-1 | ||
| 265 | Aggregates | Determination of particle shape – shape index Regulated area: 3 Aggregates |
ČSN EN 933-4 | ||
| 266 | Aggregates | Assessment of fines – sand equivalent test Regulated area: 3 Aggregates |
ČSN EN 933-8+A1 | ||
| 267 | Aggregates | Determination of loose bulk density and voids Regulated area: 3 Aggregates |
ČSN EN 1097-3, excluding Annex A | ||
| 268 | Aggregates | Determination of water content by drying in a ventilated oven Regulated area: 3 Aggregates |
ČSN EN 1097-5 | ||
| 269 | Aggregates | Determination of particle density and water absorption Regulated area: 3 Aggregates |
ČSN EN 1097-6 | ||
| 270 | Aggregates | Determination of resistance to thermal and weathering effects – freezing and thawing test Regulated area: 3 Aggregates |
ČSN EN 1367-1 | ||
| 271 | Cements | Determination of flexural and compressive strength Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 196-1, excluding chap. 5, 6, 7, 8, 11, Annex A | ||
| 272 | Mortars | Determination of compressive strength on prism halves Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-11, excluding cl. 8 | ||
| 273 | Screed materials | Determination of flexural and compressive strength Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 13892-2 | ||
| 274 | Mortars | Determination of bulk density Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-10 | ||
| 275 | Fresh concrete | Determination of consistence – slump test Regulated area: 5 Concrete |
ČSN EN 12350-2 | ||
| 276 | Fresh concrete | Determination of density Regulated area: 5 Concrete |
ČSN EN 12350-6, excluding cl. 7.4.2.1 | ||
| 277 | Fresh concrete | Determination of air content – pressure method Regulated area: 5 Concrete |
ČSN EN 12350-7, excluding cl. 5 | ||
| 278 | Hardened concrete | Determination of compressive strength of test specimens Regulated area: 5 Concrete |
ČSN EN 12390-3, excluding cl. A.5 | ||
| 279 | Hardened concrete | Determination of flexural strength of test specimens Regulated area: 5 Concrete |
ČSN EN 12390-5 | ||
| 280 | Hardened concrete | Determination of density Regulated area: 5 Concrete |
ČSN EN 12390-7 | ||
| 281 | Hardened concrete | Determination of depth of penetration of water under pressure Regulated area: 5 Concrete |
ČSN EN 12390-8 | ||
| 282 | Hardened concrete | Determination of compressive strength of cores Regulated area: 5 Concrete |
ČSN EN 12504-1, cl. 9 | ||
| 283 | Hardened concrete | Determination of frost resistance Regulated area: 5 Concrete |
ČSN 73 1322 | ||
| 284 | Hardened concrete | Determination of the resistance of cement concrete surface to water and chemical de-icing agents Regulated area: 5 Concrete |
ČSN 73 1326, Methods A, C | ||
| 285 | Hardened concrete | Determination of void volume Regulated area: 5 Concrete |
ČSN 73 6124-2, Annex A | ||
| 286 | Silicate materials | Determination of moisture content by drying at elevated temperature Regulated area: 5 Concrete |
ČSN EN ISO 12570 | ||
| 287 | Soils | Determination of water content Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-1 | ||
| 288 | Soils | Determination of particle size distribution Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-4 | ||
| 289 | Soils | Determination of consistency limits – liquid limit, plastic limit Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-12, excluding chap. 5.4 | ||
| 290 | Soils | Determination of minimum and maximum density Regulated area: 6 Soils, sub-base layers |
ČSN 72 1018 | ||
| 291 | Unbound and bound mixtures, soils | Determination of laboratory reference density and water content Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-2, excluding cl. 7.3, 7.6 and Annex B | ||
| 292 | Unbound and bound mixtures, soils | Determination of California bearing ratio, immediate bearing index and linear swelling Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-47 | ||
| 293 | Unbound and bound mixtures, soils | Determination of static deformation modulus – static plate load test Regulated area: 6 Soils, sub-base layers |
ČSN 72 1006, Annex A, B, D | ||
| 294 | Unbound and bound mixtures, soils | Determination of bulk density Regulated area: 6 Soils, sub-base layers |
ČSN 72 1010, Method A, D-1 | ||
| 295 | Unbound and bound mixtures, soils | Determination of dynamic deformation modulus – light dynamic plate method Regulated area: 6 Soils, sub-base layers |
ČSN 73 6192, group C | ||
| 296 | Hydraulically bound mixtures | Determination of compressive strength Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-41 | ||
| 297 | Hydraulically bound mixtures | Determination of resistance to frost and water Regulated area: 6 Soils, sub-base layers |
ČSN 73 6124-1, Annex A | ||
| 298 | Road surface | Measurement of unevenness Regulated area: 7 Road surfaces |
ČSN 73 6175 cl. 8 | ||
| 299 | Road surface | Measurement of unevenness Regulated area: 7 Road surfaces |
ČSN 73 6175 cl. 9 | ||
| 300 | Road surface | Measurement of macrotexture depth by the volumetric patch technique Regulated area: 7 Road surfaces |
ČSN EN 13036-1 | ||
| 301 | Concrete structures and elements, insulation layers | Determination of layer adhesion and tensile strength of surface layers Regulated area: 10 Concrete and reinforced concrete structures and elements |
ČSN 73 6242, Annex B | ||
| 302 | Concrete structures and elements, insulation layers | Determination of concrete cover to steel reinforcement Regulated area: 10 Concrete and reinforced concrete structures and elements |
IP-SQZ-01 (ČSN 73 2011, Annex A) | ||
| 303 | Aggregates | Sampling of aggregates Regulated area: Sampling |
ČSN EN 932-1 | ||
| 304 | Fresh concrete | Sampling of fresh concrete Regulated area: Sampling |
ČSN EN 12350-1 | ||
| 305 | Hardened concrete | Sampling of hardened concrete Regulated area: Sampling |
ČSN EN 12504-1, cl. 1-7 | ||
| 306 | Bituminous mixtures | Sampling of bituminous mixtures Regulated area: Sampling |
ČSN EN 12697-27 | ||
| Zbraslav – transport infrastructure laboratory | |||||
| 307 | Aggregates | Determination of particle size distribution Regulated area: 3 Aggregates |
ČSN EN 933-1 | ||
| 308 | Aggregates | Determination of particle shape – shape index Regulated area: 3 Aggregates |
ČSN EN 933-4 | ||
| 309 | Aggregates | Assessment of fines – sand equivalent test Regulated area: 3 Aggregates |
ČSN EN 933-8+A1 | ||
| 310 | Aggregates | Determination of loose bulk density and voids Regulated area: 3 Aggregates |
ČSN EN 1097-3, excluding Annex A | ||
| 311 | Aggregates | Determination of water content by drying in a ventilated oven Regulated area: 3 Aggregates |
ČSN EN 1097-5 | ||
| 312 | Aggregates | Determination of particle density and water absorption Regulated area: 3 Aggregates |
ČSN EN 1097-6 | ||
| 313 | Aggregates | Determination of resistance to thermal and weathering effects – freezing and thawing test Regulated area: 3 Aggregates |
ČSN EN 1367-1 | ||
| 314 | Aggregates | Determination of resistance to thermal and weathering effects – magnesium sulphate test Regulated area: 3 Aggregates |
ČSN EN 1367-2 | ||
| 315 | Mortars | Determination of compressive strength on prism halves Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-11, excluding cl. 8 | ||
| 316 | Mortars | Determination of flexural strength Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-11, excluding cl. 9 | ||
| 317 | Mortars | Determination of bulk density Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-10 | ||
| 318 | Fresh concrete | Determination of consistence – slump test Regulated area: 5 Concrete |
ČSN EN 12350-2 | ||
| 319 | Fresh concrete | Determination of consistence – degree of compactability Regulated area: 5 Concrete |
ČSN EN 12350-4 | ||
| 320 | Fresh concrete | Determination of consistence – flow table test Regulated area: 5 Concrete |
ČSN EN 12350-5 | ||
| 321 | Fresh concrete | Determination of density Regulated area: 5 Concrete |
ČSN EN 12350-6, excluding cl. 7.4.2.1 | ||
| 322 | Fresh concrete | Determination of air content – pressure method Regulated area: 5 Concrete |
ČSN EN 12350-7, excluding cl. 5 | ||
| 323 | Fresh concrete | Determination of setting by measuring penetration resistance by the weighing method Regulated area: 5 Concrete |
ČSN 73 1332 | ||
| 324 | Hardened concrete | Determination of compressive strength of test specimens Regulated area: 5 Concrete |
ČSN EN 12390-3, excluding cl. A.5 | ||
| 325 | Hardened concrete | Determination of flexural strength of test specimens Regulated area: 5 Concrete |
ČSN EN 12390-5 | ||
| 326 | Hardened concrete | Determination of tensile splitting strength Regulated area: 5 Concrete |
ČSN EN 12390-6 | ||
| 327 | Hardened concrete | Determination of density Regulated area: 5 Concrete |
ČSN EN 12390-7 | ||
| 328 | Hardened concrete | Determination of depth of penetration of water under pressure Regulated area: 5 Concrete |
ČSN EN 12390-8 | ||
| 329 | Hardened concrete | Determination of compressive strength of cores Regulated area: 5 Concrete |
ČSN EN 12504-1, cl. 9 | ||
| 330 | Hardened concrete | Determination of rebound number Regulated area: 5 Concrete |
ČSN EN 12504-2; ČSN 73 1373, excluding Annex A and B | ||
| 331 | Hardened concrete | Determination of the thickness of cement concrete pavement on cores Regulated area: 5 Concrete |
ČSN EN 13863-3 | ||
| 332 | Hardened concrete | Determination of frost resistance Regulated area: 5 Concrete |
ČSN 73 1322 | ||
| 333 | Hardened concrete | Determination of the resistance of cement concrete surface to water and chemical de-icing agents Regulated area: 5 Concrete |
ČSN 73 1326, Methods A, C | ||
| 334 | Hardened concrete | Determination of void volume Regulated area: 5 Concrete |
ČSN 73 6124-2, Annex A | ||
| 335 | Silicate materials | Determination of moisture content by drying at elevated temperature Regulated area: 5 Concrete |
ČSN EN ISO 12570 | ||
| 336 | Soils | Determination of water content Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-1 | ||
| 337 | Soils | Determination of particle size distribution Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-4 | ||
| 338 | Soils | Determination of consistency limits – liquid limit, plastic limit Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-12, excluding chap. 5.4 | ||
| 339 | Soils | Determination of minimum and maximum density Regulated area: 6 Soils, sub-base layers |
ČSN 72 1018 | ||
| 340 | Unbound and bound mixtures, soils | Determination of laboratory reference density and water content Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-2, excluding cl. 7.3, 7.6 and Annex B | ||
| 341 | Unbound and bound mixtures, soils | Determination of California bearing ratio, immediate bearing index and linear swelling Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-47 | ||
| 342 | Unbound and bound mixtures, soils | Determination of static deformation modulus – static plate load test Regulated area: 6 Soils, sub-base layers |
ČSN 72 1006, Annex A, B, D | ||
| 343 | Unbound and bound mixtures, soils | Determination of bulk density Regulated area: 6 Soils, sub-base layers |
ČSN 72 1010, Method A, D-1 | ||
| 344 | Unbound and bound mixtures, soils | In situ determination of California bearing ratio and immediate bearing index Regulated area: 6 Soils, sub-base layers |
ČSN 73 6186 | ||
| 345 | Unbound and bound mixtures, soils | Determination of dynamic deformation modulus – light dynamic plate method Regulated area: 6 Soils, sub-base layers |
ČSN 73 6192, group C | ||
| 346 | Hydraulically bound mixtures | Determination of compressive strength Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-41 | ||
| 347 | Hydraulically bound mixtures | Determination of resistance to frost and water Regulated area: 6 Soils, sub-base layers |
ČSN 73 6124-1, Annex A | ||
| 348 | Hydraulically bound mixtures | Determination of indirect tensile strength and water resistance Regulated area: 6 Soils, sub-base layers |
ČSN 73 6147, cl. A.2.5 and A.2.6 | ||
| 349 | Road surface | Measurement of unevenness Regulated area: 7 Road surfaces |
ČSN 73 6175 cl. 8 | ||
| 350 | Road surface | Measurement of macrotexture depth by the volumetric patch technique Regulated area: 7 Road surfaces |
ČSN EN 13036-1 | ||
| 351 | Road surface | Measurement of skid resistance – pendulum test Regulated area: 7 Road surfaces |
ČSN EN 13036-4 | ||
| 352 | Insulation | Determination of impermeability of the sealing layer Regulated area: 9 Insulation systems |
ČSN 73 6242, Annex D | ||
| 353 | Concrete and reinforced concrete structures | Pile integrity testing – PIT method Regulated area: 10 Concrete and reinforced concrete structures and elements |
IP-SQZ-02 (PIT device manual) | ||
| 354 | Concrete and reinforced concrete structures | Pile integrity testing – CHUM method Regulated area: 10 Concrete and reinforced concrete structures and elements |
IP-SQZ-03 (CHUM device manual) | ||
| 355 | Renders and plasters | Determination of adhesion of the surface finish to the substrate Regulated area: 10 Concrete and reinforced concrete structures and elements |
ČSN 73 2577 | ||
| 356 | Concrete structures and elements | Determination of adhesion by pull-off test Regulated area: 10 Concrete and reinforced concrete structures and elements |
ČSN EN 1542 | ||
| 357 | Concrete structures and elements | Determination of adhesion of protective coatings Regulated area: 10 Concrete and reinforced concrete structures and elements |
IP-SQZ-06 (ČSN 73 1344) | ||
| 358 | Concrete structures and elements, insulation layers | Determination of layer adhesion and tensile strength of surface layers Regulated area: 10 Concrete and reinforced concrete structures and elements |
ČSN 73 6242, Annex B | ||
| 359 | Concrete structures and elements, insulation layers | Determination of concrete cover to steel reinforcement Regulated area: 10 Concrete and reinforced concrete structures and elements |
IP-SQZ-01 (ČSN 73 2011, Annex A) | ||
| 360 | Bound layers | Determination of thickness Regulated area: 12 Ground-penetrating radar measurements |
IP-SQZ-08 (ASTM D 4748-10; TP-233; methodology CDV-GPR02-2017) | ||
| 361 | Joints of cement concrete pavements | Determination of the position of dowels and tie bars Regulated area: 12 Ground-penetrating radar measurements |
IP-SQZ-07 (ČSN 73 6123-1; TP-233; methodology CDV-GPR01-2016) | ||
| 362 | Concrete on bridge decks | Determination of reinforcement cover Regulated area: 12 Ground-penetrating radar measurements |
IP-SQZ-09 (ASTM D6087-08; methodology CDV-GPR02-2017) | ||
| 363 | Vertical road signs, traffic equipment | Determination of the coefficient of retroreflection Regulated area: 13 Road signs and markings |
IP-SQZ-10 (ČSN EN 12899-1; STN EN 12899-1; ČSN EN 12899-3; STN EN 12899-3; TP 143) | ||
| 364 | Vertical road signs, traffic equipment | Determination of luminance factor and chromaticity Regulated area: 13 Road signs and markings |
IP-SQZ-11 (ČSN EN 12899-1; STN EN 12899-1; ČSN EN 12899-3; STN EN 12899-3; TP 143) | ||
| 365 | Road markings, traffic equipment | Determination of chromaticity coordinates and luminance factor Regulated area: 13 Road signs and markings |
IP-SQZ-12 (ČSN EN 1436, Annex C; STN EN 1436, Annex C; TP 70) | ||
| 366 | Road markings, traffic equipment | Determination of luminance coefficient under diffuse illumination Regulated area: 13 Road signs and markings |
IP-SQZ-13 (ČSN EN 1436, Annex A; STN EN 1436, Annex A; TP 70) | ||
| 367 | Road markings, traffic equipment | Determination of coefficient of retroreflected luminance Regulated area: 13 Road signs and markings |
IP-SQZ-14 (ČSN EN 1436, Annex B; STN EN 1436, Annex B; TP 70) | ||
| 368 | Road markings, traffic equipment | Measurement of dimensions Regulated area: 13 Road signs and markings |
IP-SQZ-15 (TP 70; Act No. 361/2000 Coll.; Decree No. 294/2015 Coll.; Decree of the Ministry of Transport and Communications (MD) No. 30/2001 Coll.) | ||
| 369 | Geotextiles | Determination of mass per unit area Regulated area: 16 Geotextiles and geosynthetics |
ČSN EN ISO 9864 | ||
| 370 | Geotextiles | Determination of elongation and tensile strength Regulated area: 16 Geotextiles and geosynthetics |
ČSN EN ISO 10319, excluding Annex A | ||
| 371 | Geotextiles | Determination of water permeability Regulated area: 16 Geotextiles and geosynthetics |
ČSN EN ISO 11058, cl. 6 | ||
| 372 | Geotextiles | Static puncture test (CBR) Regulated area: 16 Geotextiles and geosynthetics |
ČSN EN ISO 12236 | ||
| 373 | Geotextiles | Dynamic perforation test (cone drop) Regulated area: 16 Geotextiles and geosynthetics |
ČSN EN ISO 13433 | ||
| 374 | Aggregates | Sampling of aggregates Regulated area: Sampling |
ČSN EN 932-1 | ||
| 375 | Fresh concrete | Sampling of fresh concrete Regulated area: Sampling |
ČSN EN 12350-1 | ||
| 376 | Hardened concrete | Sampling of hardened concrete Regulated area: Sampling |
ČSN EN 12504-1, cl. 1-7 | ||
| 377 | Geotextiles | Sampling of geotextiles Regulated area: Sampling |
ČSN EN ISO 9862 | ||
| Zbraslav – special concrete laboratory | |||||
| 378 | Aggregates | Determination of particle size distribution Regulated area: 3 Aggregates |
ČSN EN 933-1 | ||
| 379 | Aggregates | Determination of particle shape – shape index Regulated area: 3 Aggregates |
ČSN EN 933-4 | ||
| 380 | Aggregates | Determination of water content by drying in a ventilated oven Regulated area: 3 Aggregates |
ČSN EN 1097-5 | ||
| 381 | Cements | Determination of flexural and compressive strength Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 196-1, excluding chap. 5, 6, 7, 8, 11, Annex A | ||
| 382 | Cements | Determination of setting times and soundness Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 196-3 | ||
| 383 | Mortars | Determination of compressive strength on prism halves Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-11, excluding cl. 8 | ||
| 384 | Mortars | Determination of flexural strength Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-11, excluding cl. 9 | ||
| 385 | Grouts | Determination of compressive strength Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 445, cl. 4.6 | ||
| 386 | Screed materials | Determination of flexural and compressive strength Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 13892-2 | ||
| 387 | Mortars | Determination of bulk density Regulated area: 4 Cements, mortars, screed materials, grouts |
ČSN EN 1015-10 | ||
| 388 | Fresh concrete | Determination of consistence – slump test Regulated area: 5 Concrete |
ČSN EN 12350-2 | ||
| 389 | Fresh concrete | Determination of consistence – flow table test Regulated area: 5 Concrete |
ČSN EN 12350-5 | ||
| 390 | Fresh concrete | Determination of density Regulated area: 5 Concrete |
ČSN EN 12350-6, excluding cl. 7.4.2.1 | ||
| 391 | Fresh concrete | Determination of air content – pressure method Regulated area: 5 Concrete |
ČSN EN 12350-7, excluding cl. 5 | ||
| 392 | Fresh concrete | Determination of consistence – slump-flow test Regulated area: 5 Concrete |
ČSN EN 12350-8 | ||
| 393 | Hardened concrete | Determination of compressive strength of test specimens Regulated area: 5 Concrete |
ČSN EN 12390-3, excluding cl. A.5 | ||
| 394 | Hardened concrete | Determination of flexural strength of test specimens Regulated area: 5 Concrete |
ČSN EN 12390-5 | ||
| 395 | Hardened concrete | Determination of tensile splitting strength Regulated area: 5 Concrete |
ČSN EN 12390-6 | ||
| 396 | Hardened concrete | Determination of density Regulated area: 5 Concrete |
ČSN EN 12390-7 | ||
| 397 | Hardened concrete | Determination of depth of penetration of water under pressure Regulated area: 5 Concrete |
ČSN EN 12390-8 | ||
| 398 | Hardened concrete | Determination of secant modulus of elasticity in compression Regulated area: 5 Concrete |
ČSN EN 12390-13 | ||
| 399 | Hardened concrete | Determination of compressive strength of cores Regulated area: 5 Concrete |
ČSN EN 12504-1, cl. 9 | ||
| 400 | Hardened concrete | Determination of rebound number Regulated area: 5 Concrete |
ČSN EN 12504-2; ČSN 73 1373, excluding Annex A and B | ||
| 401 | Hardened concrete | Determination of the thickness of cement concrete pavement on cores Regulated area: 5 Concrete |
ČSN EN 13863-3 | ||
| 402 | Hardened concrete | Determination of static modulus of elasticity in compression Regulated area: 5 Concrete |
ČSN ISO 1920-10 | ||
| 403 | Hardened concrete | Determination of frost resistance Regulated area: 5 Concrete |
ČSN 73 1322 | ||
| 404 | Hardened concrete | Determination of the resistance of cement concrete surface to water and chemical de-icing agents Regulated area: 5 Concrete |
ČSN 73 1326, Methods A, C | ||
| 405 | Hardened concrete | Determination of void volume Regulated area: 5 Concrete |
ČSN 73 6124-2, Annex A | ||
| 406 | Young sprayed concrete | Determination of compressive strength Regulated area: 5 Concrete |
ČSN EN 14488-2 | ||
| 407 | Hardened fibre-reinforced concrete | Determination of limit of proportionality and residual flexural tensile strength Regulated area: 5 Concrete |
ČSN EN 14651+A1 | ||
| 408 | Hardened fibre-reinforced concrete | Determination of flexural load capacity (at first crack, ultimate and residual) Regulated area: 5 Concrete |
ČSN EN 14488-3 | ||
| 409 | Hardened fibre-reinforced concrete | Determination of flexural tensile strength Regulated area: 5 Concrete |
ČSN P 73 2452, cl. 8 | ||
| 410 | Soils | Determination of water content Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-1 | ||
| 411 | Unbound and bound mixtures, soils | Determination of laboratory reference density and water content Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-2, excluding cl. 7.3, 7.6 and Annex B | ||
| 412 | Unbound and bound mixtures, soils | Determination of California bearing ratio, immediate bearing index and linear swelling Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-47 | ||
| 413 | Hydraulically bound mixtures | Determination of compressive strength Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-41 | ||
| 414 | Road surface | Measurement of macrotexture depth by the volumetric patch technique Regulated area: 7 Road surfaces |
ČSN EN 13036-1 | ||
| 415 | Rock bolts | Determination of load-bearing capacity Regulated area: 8 Rock bolts |
IP-SQZ-16 (ČSN EN 1537; ČSN EN 14490; ČSN EN ISO 22477-5) | ||
| 416 | Concrete structures and elements, insulation layers | Determination of layer adhesion and tensile strength of surface layers Regulated area: 10 Concrete and reinforced concrete structures and elements |
ČSN 73 6242, Annex B | ||
| 417 | Concrete structures and elements, insulation layers | Determination of concrete cover to steel reinforcement Regulated area: 10 Concrete and reinforced concrete structures and elements |
IP-SQZ-01 (ČSN 73 2011, Annex A) | ||
| 418 | Fresh concrete | Sampling of fresh concrete Regulated area: Sampling |
ČSN EN 12350-1 | ||
| 419 | Hardened concrete | Sampling of hardened concrete Regulated area: Sampling |
ČSN EN 12504-1, cl. 1-7 | ||
| 420 | Sprayed concrete | Sampling of fresh and hardened concrete Regulated area: Sampling |
ČSN EN 14488-1 | ||
| Trocnov | |||||
| 421 | Aggregates | Determination of particle size distribution Regulated area: 3 Aggregates |
ČSN EN 933-1 | ||
| 422 | Aggregates | Determination of particle shape – shape index Regulated area: 3 Aggregates |
ČSN EN 933-4 | ||
| 423 | Aggregates | Assessment of fines – sand equivalent test Regulated area: 3 Aggregates |
ČSN EN 933-8+A1 | ||
| 424 | Aggregates | Determination of loose bulk density and voids Regulated area: 3 Aggregates |
ČSN EN 1097-3, excluding Annex A | ||
| 425 | Aggregates | Determination of water content by drying in a ventilated oven Regulated area: 3 Aggregates |
ČSN EN 1097-5 | ||
| 426 | Aggregates | Determination of particle density and water absorption Regulated area: 3 Aggregates |
ČSN EN 1097-6 | ||
| 427 | Fresh concrete | Determination of consistence – slump test Regulated area: 5 Concrete |
ČSN EN 12350-2 | ||
| 428 | Fresh concrete | Determination of density Regulated area: 5 Concrete |
ČSN EN 12350-6, excluding cl. 7.4.2.1 | ||
| 429 | Fresh concrete | Determination of air content – pressure method Regulated area: 5 Concrete |
ČSN EN 12350-7, excluding cl. 5 | ||
| 430 | Hardened concrete | Determination of compressive strength of test specimens Regulated area: 5 Concrete |
ČSN EN 12390-3, excluding cl. A.5 | ||
| 431 | Hardened concrete | Determination of density Regulated area: 5 Concrete |
ČSN EN 12390-7 | ||
| 432 | Hardened concrete | Determination of depth of penetration of water under pressure Regulated area: 5 Concrete |
ČSN EN 12390-8 | ||
| 433 | Hardened concrete | Determination of compressive strength of cores Regulated area: 5 Concrete |
ČSN EN 12504-1, cl. 9 | ||
| 434 | Hardened concrete | Determination of the resistance of cement concrete surface to water and chemical de-icing agents Regulated area: 5 Concrete |
ČSN 73 1326, Methods A, C | ||
| 435 | Hardened concrete | Determination of void volume Regulated area: 5 Concrete |
ČSN 73 6124-2, Annex A | ||
| 436 | Soils | Determination of water content Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-1 | ||
| 437 | Soils | Determination of particle size distribution Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-4 | ||
| 438 | Soils | Determination of consistency limits – liquid limit, plastic limit Regulated area: 6 Soils, sub-base layers |
ČSN EN ISO 17892-12, excluding chap. 5.4 | ||
| 439 | Soils | Determination of minimum and maximum density Regulated area: 6 Soils, sub-base layers |
ČSN 72 1018 | ||
| 440 | Unbound and bound mixtures, soils | Determination of laboratory reference density and water content Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-2, excluding cl. 7.3, 7.6 and Annex B | ||
| 441 | Unbound and bound mixtures, soils | Determination of California bearing ratio, immediate bearing index and linear swelling Regulated area: 6 Soils, sub-base layers |
ČSN EN 13286-47 | ||
| 442 | Unbound and bound mixtures, soils | Determination of static deformation modulus – static plate load test Regulated area: 6 Soils, sub-base layers |
ČSN 72 1006, Annex A, B, D | ||
| 443 | Unbound and bound mixtures, soils | Determination of bulk density Regulated area: 6 Soils, sub-base layers |
ČSN 72 1010, Method A, D-1 | ||
| 444 | Unbound and bound mixtures, soils | Determination of dynamic deformation modulus – light dynamic plate method Regulated area: 6 Soils, sub-base layers |
ČSN 73 6192, group C | ||
| 445 | Road surface | Measurement of unevenness Regulated area: 7 Road surfaces |
ČSN 73 6175 cl. 8 | ||
| 446 | Road surface | Measurement of unevenness Regulated area: 7 Road surfaces |
ČSN 73 6175 cl. 9 | ||
| 447 | Road surface | Measurement of macrotexture depth by the volumetric patch technique Regulated area: 7 Road surfaces |
ČSN EN 13036-1 | ||
| 448 | Concrete structures and elements, insulation layers | Determination of layer adhesion and tensile strength of surface layers Regulated area: 10 Concrete and reinforced concrete structures and elements |
ČSN 73 6242, Annex B | ||
| 449 | Aggregates | Sampling of aggregates Regulated area: Sampling |
ČSN EN 932-1 | ||
| 450 | Fresh concrete | Sampling of fresh concrete Regulated area: Sampling |
ČSN EN 12350-1 | ||
| 451 | Hardened concrete | Sampling of hardened concrete Regulated area: Sampling |
ČSN EN 12504-1, cl. 1-7 | ||
| Sewer measurement | |||||
| 452 | Sewers and sewer connections | Watertightness test – method L Regulated area: 14 Sewer measurement |
ČSN 75 6909, cl. 8.4 | ||
| 453 | Sewers and sewer connections | Measurement of deformation of the flow cross-section Regulated area: 14 Sewer measurement |
IP-SQZ-04 (ČSN EN 13508-1, cl. 5.8.4 b) | ||
| 454 | Sewers and sewer connections | Measurement of gradient Regulated area: 14 Sewer measurement |
IP-SQZ-05 (TKP chap. 3, Appendix 1, cl. 3.P2.3; ČSN EN 13508-1) | ||
| Physical quantities | |||||
| 455 | Working environment | Noise measurement Regulated area: 15 Measurement of environmental factors |
ČSN EN ISO 9612; STN EN ISO 9612; Bulletin of the Ministry of Health (MZd) 2013, issue 4; Government Regulation of the Slovak Republic (NV SR) No. 115/2006 Coll. (Z.z.); Government Regulation of the Slovak Republic (NV SR) No. 555/2006 Coll. (Z.z.) for the purposes of Act No. 355/2007 Coll. (Z.z.) | ||
| 456 | Non-working environment | Noise measurement Regulated area: 15 Measurement of environmental factors |
ČSN ISO 1996-1; STN ISO 1996-1; ČSN ISO 1996-2; STN ISO 1996-2; ČSN EN ISO 16032; ČSN EN ISO 3746; ČSN ISO 11819-1; Bulletin of the Ministry of Health (MZd) of the Czech Republic, volume 2023, issue 14; Decree of the Ministry of Health of the Slovak Republic (MZ SR) No. 549/2007 Coll. (Z.z.) for the purposes of Act No. 355/2007 Coll. (Z.z.) | ||
| 457 | Working environment | Gravimetric determination of dustiness (including the fibrogenic SiO2 component) Regulated area: 15 Measurement of environmental factors |
IP-SQZ-17, chap. 10 (ČSN EN 689+AC; HEM-340-22.1.02/1890; Government Regulation No. 361/2007 Coll.) | ||
| 458 | Working environment | Measurement of concentration – CO, O2 electrochemically – CO2 by infrared spectrometry Carbon monoxide (CO) Oxygen (O2) Carbon dioxide (CO2) Regulated area: 15 Measurement of environmental factors |
IP-SQZ-18 (ČSN EN 482; ČSN EN 689+AC; Government Regulation No. 361/2007 Coll.; MultiRAE multi-gas analyser manual) | ||
| 459 | Working and non-working environment | Assessment and measurement of electric lighting Regulated area: 15 Measurement of environmental factors |
ČSN 36 0011-1; ČSN 36 0011-3 | ||
| 460 | Working environment | Vibration measurement Regulated area: 15 Measurement of environmental factors |
ČSN EN ISO 5349-1; ČSN EN ISO 5349-2; ČSN ISO 2631-1; ČSN ISO 2631-2; ČSN EN 14253+A1; Bulletin of the Ministry of Health (MZd) 2013, issue 4 | ||
| 461 | Non-working environment | Vibration measurement Regulated area: 15 Measurement of environmental factors |
ČSN ISO 2631-1; ČSN ISO 2631-2; Bulletin of the Ministry of Health (MZd) 2013, issue 4; ČSN 73 0040 | ||
| 462 | Internal and external separating and envelope structures | Measurement of sound insulation Regulated area: 15 Measurement of environmental factors |
ČSN ISO 10847; ČSN EN ISO 3382-2; ČSN EN ISO 16283-1; ČSN EN ISO 16283-2; ČSN EN ISO 16283-3; ČSN EN ISO 717-1; ČSN EN ISO 717-2 | ||
| 463 | Working environment | Sampling for gravimetric determination of dustiness Regulated area: Sampling |
IP-SQZ-17, chap. 2 (ČSN EN 689+AC; HEM-340-22.1.02/1890; Government Regulation No. 361/2007 Coll.) | ||
Reference standards (194)
ASTM D 4748-10
ASTM D6087-08
HEM-340-22.1.02/1890
IP-SQZ-01
IP-SQZ-02
IP-SQZ-03
IP-SQZ-04
IP-SQZ-05
IP-SQZ-06
IP-SQZ-07
IP-SQZ-08
IP-SQZ-09
IP-SQZ-10
IP-SQZ-11
IP-SQZ-12
IP-SQZ-13
IP-SQZ-14
IP-SQZ-15
IP-SQZ-16
IP-SQZ-17, kap. 10
IP-SQZ-17, kap. 2
IP-SQZ-18
Manuál k zařízení CHUM
Manuál k zařízení PIT
Manuál multifunkčního analyzátoru MultiRAE
Metodika CDV-GPR01-2016
Metodika CDV-GPR02-2017
Government Regulation of the Slovak Republic (NV SR) No. 115/2006 Coll. (Z.z.)
Government Regulation of the Slovak Republic (NV SR) No. 555/2006 Coll. (Z.z.) for the purposes of Act No. 355/2007 Coll. (Z.z.)
Government Regulation No. 361/2007 Coll.
STN EN 12697-12, Method A
STN EN 12697-22+A1
STN EN 12697-23
STN EN 12697-29, cl. 5.2, 5.3
STN EN 12697-6
STN EN 12899-1
STN EN 12899-3
STN EN 13398
STN EN 1436, Annex A
STN EN 1436, Annex B
STN EN 1436, Annex C
STN EN ISO 9612
STN ISO 1996-1
STN ISO 1996-2
TKP kap. 3, dodatek č. 1, čl. 3.P2.3
TP 143
TP 70
TP-233
Vyhláška MD a S č. 30/2001 Sb.
Decree of the Ministry of Health of the Slovak Republic (MZ SR) No. 549/2007 Coll. (Z.z.) for the purposes of Act No. 355/2007 Coll. (Z.z.)
Decree No. 294/2015 Coll.
Bulletin of the Ministry of Health (MZd) 2013, issue 4
Bulletin of the Ministry of Health (MZd) of the Czech Republic, volume 2023, issue 14
Act No. 361/2000 Coll.
ČSN 36 0011-1
ČSN 36 0011-3
ČSN 72 1006, Annex A, B, D
ČSN 72 1010, Method A, D-1
ČSN 72 1018
ČSN 72 1176, Method A
ČSN 72 1180
ČSN 72 1187
ČSN 73 0040
ČSN 73 1322
ČSN 73 1326, Methods A, C
ČSN 73 1332
ČSN 73 1344
ČSN 73 1373, excluding Annex A and B
ČSN 73 2011, příloha A
ČSN 73 2577
ČSN 73 6123-1
ČSN 73 6124-1, Annex A
ČSN 73 6124-2, Annex A
ČSN 73 6147, cl. A.2.5 and A.2.6
ČSN 73 6160, cl. 7.2, method a), c)
ČSN 73 6160, cl. 7.2, method b)
ČSN 73 6160, cl. 7.3
ČSN 73 6161
ČSN 73 6175 cl. 8
ČSN 73 6175 cl. 9
ČSN 73 6186
ČSN 73 6192, group C
ČSN 73 6242, Annex B
ČSN 73 6242, Annex D
ČSN 75 6909, cl. 8.4
ČSN EN 1015-10
ČSN EN 1015-11, excluding cl. 8
ČSN EN 1015-11, excluding cl. 9
ČSN EN 1097-2, cl. 1-5
ČSN EN 1097-3, excluding Annex A
ČSN EN 1097-5
ČSN EN 1097-6
ČSN EN 1097-7
ČSN EN 12350-1
ČSN EN 12350-2
ČSN EN 12350-4
ČSN EN 12350-5
ČSN EN 12350-6, excluding cl. 7.4.2.1
ČSN EN 12350-7, excluding cl. 5
ČSN EN 12350-8
ČSN EN 12390-13
ČSN EN 12390-3, excluding cl. A.5
ČSN EN 12390-5
ČSN EN 12390-6
ČSN EN 12390-7
ČSN EN 12390-8
ČSN EN 12504-1, cl. 1-7
ČSN EN 12504-1, cl. 9
ČSN EN 12504-2
ČSN EN 12697-1
ČSN EN 12697-12, Method A
ČSN EN 12697-13
ČSN EN 12697-18, cl. 5
ČSN EN 12697-2
ČSN EN 12697-22+A1
ČSN EN 12697-23
ČSN EN 12697-27
ČSN EN 12697-29, cl. 5.2, 5.3
ČSN EN 12697-34
ČSN EN 12697-36, cl. 6.1
ČSN EN 12697-5
ČSN EN 12697-6
ČSN EN 12697-8
ČSN EN 12899-1
ČSN EN 12899-3
ČSN EN 13036-1
ČSN EN 13036-4
ČSN EN 13286-2, excluding cl. 7.3, 7.6 and Annex B
ČSN EN 13286-41
ČSN EN 13286-47
ČSN EN 13398
ČSN EN 13508-1
ČSN EN 13508-1, čl. 5.8.4 b
ČSN EN 1367-1
ČSN EN 1367-2
ČSN EN 13863-3
ČSN EN 13892-2
ČSN EN 14253+A1
ČSN EN 1426
ČSN EN 1427
ČSN EN 1436, příloha A
ČSN EN 1436, příloha B
ČSN EN 1436, příloha C
ČSN EN 14488-1
ČSN EN 14488-2
ČSN EN 14488-3
ČSN EN 14488-6
ČSN EN 14490
ČSN EN 14651+A1
ČSN EN 1537
ČSN EN 1542
ČSN EN 196-1, excluding chap. 5, 6, 7, 8, 11, Annex A
ČSN EN 196-3
ČSN EN 445, cl. 4.6
ČSN EN 482
ČSN EN 689+AC
ČSN EN 932-1
ČSN EN 933-1
ČSN EN 933-3
ČSN EN 933-4
ČSN EN 933-5
ČSN EN 933-8+A1
ČSN EN 933-9
ČSN EN ISO 10319, excluding Annex A
ČSN EN ISO 11058, cl. 6
ČSN EN ISO 12236
ČSN EN ISO 12570
ČSN EN ISO 13433
ČSN EN ISO 16032
ČSN EN ISO 16283-1
ČSN EN ISO 16283-2
ČSN EN ISO 16283-3
ČSN EN ISO 17892-1
ČSN EN ISO 17892-12, excluding chap. 5.4
ČSN EN ISO 17892-4
ČSN EN ISO 2178
ČSN EN ISO 22477-5
ČSN EN ISO 3382-2
ČSN EN ISO 3746
ČSN EN ISO 5349-1
ČSN EN ISO 5349-2
ČSN EN ISO 717-1
ČSN EN ISO 717-2
ČSN EN ISO 9612
ČSN EN ISO 9862
ČSN EN ISO 9864
ČSN ISO 10847
ČSN ISO 11819-1
ČSN ISO 1920-10
ČSN ISO 1996-1
ČSN ISO 1996-2
ČSN ISO 2631-1
ČSN ISO 2631-2
ČSN P 73 2452, cl. 8